Comparison with ABCHES and Abdomen Compression Device in Respirational Radiation Therapy on Patients in Hepatocellular Carcinoma (간세포암 환자에서 ABCHES와 복부압박장비의 적용한 호흡동조방사선 치료의 유용성 비교)

  • Cho, Yoon-Jin;Byun, Sang-Joon;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.395-402
    • /
    • 2012
  • 4D-Radiation Therapy is the optimal treatment to track moving organs(tumor) and give the appropriate prescription dose to tumor and low radiation dose to normal tissue surrounding tumor volume. The ABCHES is a 4DRT devices maintaining shallow breathing to patients. It allows the tumor's movement was minimize. Meanwhile, Abdominal compression device is limited the breath compressing abdomen on patients. In this paper we will quantitative analysis the movement of tumor on only ABCHES versus ABCHES with Abdomal compression device and Analysis tumor dose and normal tissue's dose by Dose Volume Histogram on two parts. The result of Comparision ABCHES and ABCHES with Abdominal compression device, SI(Superior-Inferior) direction, AP(Anterior-Posterior) direction and LR(Left-Right) direction was limited 1.0 mm, 0.2 mm, 0.2 mm(average). and also reduction rate of voluume in HPTV was $16{\pm}2%$, and LPTV was $15.8{\pm}0.8%$ under only using ABCHES and ABCHES with compression. The analysis dose volume histogram was more radiation dose in ABCHES and abdominal compression device than only using ABCHES, and less normal tissue-ipsilateral lung, whole lung, kidney-dose in ABCHES and abdominal compression device than only using ABCHES. The overall analysis was ABCHES with abdominal compression better than only using ABCHES method. In hereafter it will be studies that limitation of ABCHES and abdomonal compression device. In other words, patient's discomfort on compression intensity, method of application on patient with inaccurate respiration cycle.

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer (피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정)

  • Chu, Sung-Sil;Loh, John-Jk;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a $0.5\;cm\times90\;cm{\times}180\;cm$ acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.

  • PDF

The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation (골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.271-279
    • /
    • 2008
  • Purpose: To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, $1{\sim}79%$) and was statistically significant (p<0.001). The reduction in small bowel volume receiving $10{\sim}100%$ of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and $90{\sim}99%$ in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), $90{\sim}99%$ in 7/22 patients (32%), and $80{\sim}89%$ in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is recommended to be considerate in using the BBD when bladder damage is of concern.

Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT (CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가)

  • Kim, Dong-Hyun;Ko, Sung-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Choi, Seok-Yoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.331-338
    • /
    • 2013
  • CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study (팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가)

  • Bahn, Young-Kag;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.53-59
    • /
    • 2011
  • Purpose: To evaluate the dosimetry and image of very low does CT attenuation correction for phantom using pediatric PET/CT. Materials and methods: three PET / CT scanners (Discovery STe, BiographTruepoint 40, Discovery 600) as a child-size acrylic phantom and ion chamber dosimeter (Unfous Xi CT, Sweden) using a CT image acquisition parameters (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp) by varying the depth dose and evaluate $CTDI_{vol}$ value. And each attenuation corrected PET/CT images used NEMA PET Phantom$^{TM}$ (NU2-1994) was evaluated by SUV. Results: Abdominal diagnosis CT dose in general pediatric (about 10 ages) parameter (100 kVp, 100 mA) than very low dose CT parameter (80 kVp, 10 mA) at the depth dose was reduced approximately 92%, $CTDI_{vol}$ was reduced to about 88%. Each CT attenuation corrected parameters PET images showed no change in the value of SUV. Conclusion: for pediatric patients, PET/CT scan can be obtained with very low dose attenuation correction CT (80 kVp, 10 mA), and such attenuation correction CT dose was reduced 100 fold than diagnosis CT dose. PET / CT scan used very low dose CT attenuation correction in pediatric patients can be helpful in reducing radiation dose.

  • PDF

구내 방사선 촬영에 있어서 Film과 Digital sensor에 따른 피폭선량의 차이에 대한 비교

  • Kim, Ju-Yeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.45-49
    • /
    • 2005
  • 목적 : 기존 구내 방사선 촬영에서 사용되었던 Film에서의 노출선량과 Digital Sensor를 이용한 구내 디지털 촬영에서의 노출선량을 비교하여 현재 광범위 하게 사용 되어지고 있는 Digital Sensor가 환자의 피폭선량을 감소하는데 기여하는 정도를 알아본다. 대상 및 방법 : 치아 우식증이 없는 5개의 구치부 치아를 선택하여 석고 블럭에 매식한 후 교합면과 인접면에 우식병소들을 형성하였다. 이를 필름(Kodak Insight; IS, Kodak Co, USA)과 Digital Sensor(Kodak RVG 6000; Kodak Co, USA)에 XCP Instrument(Rinn Co, USA)를 사용하고, 전면에는 조직등가물질인 Acrylic Resin Block 20mm를 설치하였다. Acrylic Resin Block의 관구 측면 에서는 조사선량계를 부착하여 단계별로 변화시키는 노출조건에 대한 조사선량을 측정하였다. 그리고 이렇게 얻어진 영상을 3명의 방사선학 전공의와 1명 의 보존과 전공의가 평가를 하였다. 결과 : Film과 Digital Sensor를 가지고 촬영한 영상을 분석한 결과 노출선량에서도 Digital Sensor는 Film 노출선량과 비슷한 결과를 도출해 낼 수 있었다. 그러나 Digital Sensor로 촬영된 영상의 경우에는 Film 경우보다 좀더 효과적으로 조사선량을 판단 할 수 있었으며, 또한 영상 판독시 필름보다 폭 넓게 응용 할 수 있었다. 결론 : 본 연구에서는 선량 변화에만 의존하는 것이 아니라 Digital Sensor로 촬영시 영상 조절을 병행한다면 좀더 정확하고 효과적인 진단 활동에 도움이 될 수 있을 것으로 사료된다.

  • PDF

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF