• Title/Summary/Keyword: 환원황

Search Result 204, Processing Time 0.031 seconds

Autotrophic Perchlorate-Removal Using Elemental Sulfur Granules and Activated Sludge: Batch Test (원소 황 입자와 활성 슬러지를 이용한 독립영양방식의 퍼클로레이트 제거: 회분배양연구)

  • Han, Kyoung-Rim;Kang, Tae-Ho;Kang, Hyung-Chang;Kim, Kyung-Hun;Seo, Deuk-Hwa;Ahn, Yeong-Hee
    • Journal of Life Science
    • /
    • v.21 no.10
    • /
    • pp.1473-1480
    • /
    • 2011
  • Perchlorate ($ClO_4^-$) is a contaminant found in surface water and soil/ground water. Microbial removal of perchlorate is the method of choice since microorganisms can reduce perchlorate into harmless end-products. Such microorganisms require an electron donor to reduce perchlorate. Conventional perchlorate-removal techniques employ heterotrophic perchlorate-reducing bacteria that use organic compounds as electron donors to reduce perchlorate. Since continuous removal of perchlorate requires a continuous supply of organic compounds, heterotrophic perchlorate removal is an expensive process. Feasibility of autotrophic perchlorate-removal using elemental sulfur granules and activated sludge was examined in this study. Granular sulfur is relatively inexpensive and activated sludge is easily available from wastewater treatment plants. Batch tests showed that activated sludge microorganisms could successfully degrade perchlorate in the presence of granular sulfur as an electron donor. Perchlorate biodegradation was confirmed by molar yield of $Cl^-$ as the perchlorate was degraded. Scanning electron microscope revealed that rod-shaped microorganisms on the surface of sulfur particles were used for the autotrophic perchlorate-removal, suggesting that sulfur particles could serve as supporting media for the formation of biofilm as well. DGGE analyses revealed that microbial profile of the inoculum (activated sludge) was different from that of the biofilm sample obtained from enrichment culture that used sulfur particles for $ClO_4^-$-degradation.

Biological reduction of perchlorate containing high salinity (고농도 염을 포함한 퍼클로레이트의 생물학적 환원)

  • Hwang, Jungwon;Park, Doori;Lee, Kanghoon;Yeom, Icktae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.284-284
    • /
    • 2015
  • 본 연구는 퍼클로레이트의 생물학적 환원 과정에 있어서 고농도의 염이 미생물에게 어떤 영향을 미치는지를 다양한 방법을 통해서 알아보고 적절한 모델링 접근을 통하여 최적 환원속도를 위한 반응조 조건 및 설계에 필요한 요소들을 도출하기 위해 수행되었다. 100mL 합성폐수를 포함하는 플라스크를 이용한 실험이 수행되었고, 일정 농도의 퍼클로레이트와 유일 탄소원으로 아세트산나트륨이 사용되었다. 염화나트륨 농도가 $7490{\mu}s/cm$에서 $23700{\mu}s/cm$까지 증가하는 동안 퍼클로레이트의 생물학적 환원 속도는 현저하게 감소하였으며, $32100{\mu}s/cm$ 이상의 염화나트륨 농도에서는 퍼클로레이트가 환원되지 않았다. 동일한 농도의 염화나트륨, 염화암모늄, 염산 및 황산이 포함된 하수에서는 퍼클로레이트의 환원속도가 모두 비슷하였다.

  • PDF

Metal Corrosion Mechanism by Sulfate-reducing and Iron-oxidizing Bacteria in Saline System and its Optimal Inactivation (염수계 철산화균 및 황환원균에 의한 금속 부식 및 최적 제어 방안)

  • Sung, Eun-Hae;Han, Ji-Sun;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.798-807
    • /
    • 2008
  • Due to economic impairment derived from metal corrosion of pumping station installed around coastal area, it was needed for related cause-effect to be investigated for understanding practical corrosion behavior and providing proper control. This research was thus carried out to determine whether the microbe can influence on metal corrosion along with its control in the laboratory. For this study, groundwater was sampled from the underground pump station(i.e. I Gas Station) where corrosion was observed. Microbial diversity on the samples were then obtained by 16S rDNA methods. From this, microbial populations showing corrosion behaviors against metals were reported as Leptothrix sp.(Iron oxidizing) and Desulfovibrio sp.(Sulfur reducing) Iron oxidizing bacteria were dominantly participating in the corrosion of iron, while sulfate reducing bacteria were more preferably producing precipitate of iron. In case of galvanized steel and stainless steel, iron oxidizing bacteria not only enhanced the corrosion, but also generated its scale of precipitate. Sulfate reducing bacteria had zinc steel corroded greater extent than that of iron oxidizing bacteria. In the inactivation test, chlorine or UV exposure could efficiently control bacterial growth. However as the inactivation intensity being increased beyond a threshold level, corrosion rate was unlikely escalated due to augmented chemical effect. It is decided that microbial corrosion could be differently taken place depending upon type of microbes or materials, although they were highly correlated. It could be efficiently retarded by given disinfection practices.

Investigation of Catalytic Deactivation by Small Content Oxygen Contained in Regeneration Gas Influenced on DSRP (직접 황 회수 공정으로 유입되는 재생가스에 함유된 미량산소의 촉매활성저하 원인 규명)

  • Choi, Hee-Young;Park, No-Kuk;Lee, Tae Jin
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.212-217
    • /
    • 2014
  • In order to regenerate the sulfidated desulfurization sorbent, oxygen is used as the oxidant agent on the regeneration process. The small amount of oxygen un-reacted in regeneration process is flowed into direct sulfur recovery process. However, the reactivity for $SO_2$ reduction can be deteriorated with the un-reacted oxygen by various reasons. In this study, the deactivation effects of un-reacted oxygen contained in the off-gas of regeneration process flowed into direct sulfur recovery process of hot gas desulfurization system were investigated. Sn-Zr based catalysts were used as the catalyst for $SO_2$ reduction. The contents of $SO_2$ and $O_2$ contained in the regenerator off-gas used as the reactants were fixed to 5.0 vol% and 4.0 vol%, respectively. The catalytic activity tests with a Sn-Zr based catalyst were for $SO_2$ reduction performed at $300-450^{\circ}C$ and 1-20 atm. The un-reacted oxygen oxidized the elemental sulfur produced by $SO_2$ catalytic reduction and the conversion of $SO_2$ was reduced due to the production of $SO_2$. However, the temperature for the oxidation of elemental sulfur increased with increasing pressure in the catalytic reactor. Therefore, it was concluded that the decrease of reactivity at high pressure is occurred by catalytic deactivation, which is the re-oxidation of lattice oxygen vacancy in Sn-Zr based catalyst with the un-reacted oxygen on the catalysis by redox mechanism. Meanwhile the un-reacted oxygen oxidized CO supplied as the reducing agent and the temperature in the catalyst packed bed also increased due to the combustion of CO. It was concluded that the rapidly increasing temperature in the packed bed can induce the catalytic deactivation such as the sintering of active components.

The Reactivity for the SO2 Reduction with CO and H2 over Sn-Zr Based Catalysts (Sn-Zr계 촉매 상에서 CO와 H2를 이용한 SO2 환원 반응특성)

  • Han, Gi Bo;Park, No-Kuk;Ryu, Si Ok;Lee, Tae Jin
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.356-362
    • /
    • 2006
  • The $SO_2$ reduction using CO and $H_2$ over Sn-Zr based catalysts was performed in this study. Sn-Zr based catalysts with Sn/Zr molar ratio (0/1, 1/4, 1/1, 2/1, 3/1, 1/0) were prepared by the precipitation and co-precipitation method. The effect of the temperature on the reaction characteristics of the $SO_2$ reduction with a reducing agent such as $H_2$ and CO was investigated under the conditions of space velocity of $10,000ml/g_{-cat.}h$, $([CO(or\;H_2)]/[SO_2])$ of 2.0. As a result, the activity of Sn-Zr based catalysts were higher than $SnO_2$ and $ZrO_2$. The reactivity for the $SO_2$ reduction with CO was higher than that with $H_2$, and sulfur yield in the $SO_2$ reduction by $H_2$ was higher than that by CO. The reactivity for the $SO_2$ reduction with $H_2$ was increased with the reaction temperature regardless of Sn-Zr based catalyst with a Sn/Zr molar ratio. $SnO_2-ZrO_2$ (Sn/Zr=1/4) had highest activity at $550^{\circ}C$, in the $SO_2$ reduction with $H_2$ and $SO_2$ conversion of 94.4% and sulfur yield of 66.4% were obtained at $550^{\circ}C$. On the other hand, in the $SO_2$ reduction by CO, the reactivity was decreased with the increase over $325^{\circ}C$. At the optimal temperature of $325^{\circ}C$, $SO_2$ conversion and sulfur yield were about 100% and 99.5%, respectively, in the $SO_2$ reduction over $SnO_2-ZrO_2$ (Sn/Zr=3/1). Also, the $SO_2$ reduction using syngas with $CO/H_2$ ratio over $SnO_2-ZrO_2$ (Sn/Zr=2/1) was performed in order to investigate the application possibility of the simulated coal gas as the reductant in DSRP. As a result, the reactivity of the $SO_2$ reduction using syngas with $CO/H_2$ ratio was increased with increasing the CO content of syngas. Therefore, it could be known that DSRP using the simulated coal gas over Sn-Zr based catalyst is possible to be realized in IGCC system

Synthesis of Silver Nano-Particles using Alcohol Reducing Process and Antibacterial Properties of its Ag/PET Master Batch (알코올환원법을 이용한 은나노입자 제조 및 이를 함유한 Ag/PET 마스터배치칩의 항균특성에 관한 연구)

  • Son, Eun-Jong;Hwang, Young-Gu;Shin, Yu-Shik;Jung, Gi-Hoon;Jung, Hae-Rim;Jeong, Sung-Hoon
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.56-56
    • /
    • 2011
  • 알코올 환원법(alcohol reducing process)은 화학적 환원제가 필요하지 않은 화학합성법으로 메탄올, 에탄올, 프로판올, 이소프로판올, 부탄올 등 C1-C4의 알코올류, 에틸렌 글라이콜, 디에틸렌 글라이콜, 프로필렌 글라이콜과 같은 글리콜류 등이 용매이자 환원제로써 사용된다. 전형적으로 금속 전구체를 상기의 알코올류나 글리콜류에 용해 또는 분산시킨 후 그 용액을 환류 조건하에서 가열하게 되면 금속 이온과 용매간의 산화, 환원반응에 의하여 금속이온이 금속원자로 환원되며, 환원된 금속 입자들은 핵 행성과 성장 과정을 거쳐서 입자를 형성하게 된다. 본 연구에서는 알코올환원법을 이용하여 나노크기의 은입자제조를 시도하였고, 이를 PET 칩과의 마스터배치 제조을 시도하였으며, 이의 항균성능을 연구 고찰하였다. 30 ~ 80 nm의 은파우더를 제조할 수 있었으며, 우수한 항균성능을 갖는 Ag/PET 마스터배치를 제조할 수 있었다. 이를 활용하여 나노은입자기반의 항균섬유을 제조하여 이를 활용한 기모경편성물 제조의 기초데이타로 활용이 가능하리라고 사료된다.

  • PDF

Study on Determination of Design Factor of Bioreactor for Sulfate Reduction in Mine Drainage (광산배수 내 황산염 저감을 위한 생물반응기의 설계인자 도출 연구)

  • Kim, Kang-Ho;Kang, Chan-Ung;Kim, Sun-Joon;Kim, Tae-Heok;Ji, Won-Hyun;Jang, Hang-Seok;Park, Hyun-Sung
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.527-537
    • /
    • 2018
  • Column tests of a sulfate reducing bacteria (SRB) bioreactor were conducted to determine the design factors for sulfate-rich mine drainage. Various substrates were applied to the bioreactor, including cow manure and its mixture with a mushroom compost, with rice straw and limestone as subsidiary materials. This procedure provided a removal efficiency of up to 82% of the total sulfur with the mixture of cow manure (70%), mushroom compost (10%) and rice straw (20%), and higher efficiencies were observed after 2 days of retention time. In the downflow condition of the flow direction, oxygen supply and re-oxidation of the sulfates occurred, causing a decrease in sulfate removal efficiency. The addition of an inorganic sludge containing heavy metals, which was intended for production of metal-sulfides in the bioreactor, had a negative effect on the long-term operation owing to arsenic release and toxicity to the SRB. The results thus show that a bioreactor using a mixed substrate with cow manure and operating in the downflow direction could reduce sulfates and total dissolved sulfur content; this process confirms the applicability of the SRB bioreactor to sulfate-rich saline drainage.

Reduction Characteristics of Hexavalent Chromium in Cement/Fe(II) Systems

  • 강희석;서진권;황인성;박주양
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.233-236
    • /
    • 2002
  • 다양한 산업활동에 의하여 발생하는 6가 크롬 (Cr(Ⅵ))은 대표적인 토양 및 지하수 오염물질이다. Cr(Ⅵ)은 3가크롬(Cr(III))로의 환원에 의한 침전반응으로 이동성이 저하된다고 알려져 있다. 본 연구에서는 기존의 고형화/안정화 공정에 환원.분해 반응을 추가한 2가철 기반 분해성 고형화/안정화(Degradative Solidification/Stabilization)공정에 의한 Cr(Ⅵ) 처리 특성을 고찰하였다. 회분식 실험결과 cemen/Fe(II) system내에 Cr(Ⅵ)은 환원반응 뿐만 아니라 cement에 의한 침전에 의해서도 제거됨이 밝혀졌다. Cr(Ⅵ)의 제거속도는 Fe(II)의 반응당량에 비례하는 것으로 보여진 반면, cement/solution ratio에 따른 Cr(Ⅵ) 제거동역학의 차이는 그다지 크지 않았다

  • PDF