• Title/Summary/Keyword: 환기 해석

Search Result 519, Processing Time 0.027 seconds

Heat Transfer Characteristics of Cost Effective Plate Fin-tube Condenser for Household Refrigerator (가정용 냉장고의 응축기 비용저감을 위한 판형 핀-관 열교환기의 열전달 특성)

  • Son, Young-Woo;Lee, Jang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.323-327
    • /
    • 2008
  • 본 연구는 판형 핀-관 열교환기의 열전달 특성을 상용 CFD 코드인 SC/Tetra를 사용하여 해석한 내용에 관한 것이다. 해석조건은 입구속도 0.63 m/s, 튜브온도 $44.5^{\circ}C$이다. 해석 열교환기는 총6가지로 검토하였으며 각각의 온도분포와 유동패턴을 해석하고 판형 핀-관 열교환기의 열전달 특성을 비교 검토하였다.

  • PDF

A fundamental study on the ventilation analysis method for the network-type tunnel - focused on the none hardy-cross method (네트워크형 터널의 환기해석 방법에 대한 기초연구-비 Hardy-Cross 방법을 중심으로)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.291-303
    • /
    • 2016
  • Recently, various forms of diverging sections in tunnels have been designed as the demand for underground passageway in urban areas increases. Therefore, the complexity of the ventilation system in tunnels with diverging sections requires a ventilation analysis method different from the conventional method for the straight tunnels. None of the domestic and foreign tunnel ventilation design standards specifies the method for the ventilation network analysis, and the numerical analysis methods have been most widely used. This paper aims at reviewing the ventilation network analytical method applicable as the design standard. The proposed method is based on the characteristic equations rather than the numerical analysis. Thanks to the advantages of easy application, the Hardy-Cross method has been widely applied in the fields of mine ventilation and tunnel ventilation. However, limitations with the cutting errors in the Taylor series expansion and the convergence problem mainly caused by the mesh selection algorithm have been reported. Therefore, this paper examines the applicability of the ventilation analysis method for network-type tunnels with the gradient method that can analyze flow rate and pressure simultaneously without the configuration of mesh. A simple ventilation analysis method for network-type tunnels is proposed.

A Study on the Behaviour of Smoke Spread Caused by Vehicle Fire in a Road Tunnel (터널 내 차량 화재에 따른 연기 확산 거동에 관한 연구)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.365-372
    • /
    • 2012
  • This paper aims to evaluate the effects that presence, installation number and capacity of ventilation vent and presence of multiple fire sources have on the behaviour of smoke temperature induced by vehicle fire in road tunnel. Six types of scenarios were assumed and FDS was ran to simulate them. As the number of ventilation vents increases, the smoke temperature are calculated to be reduced, but it is shown that effects exerted by two ventilation vents are almost similar to ones by three ventilation vents. Capacity of ventilation vent has a greater impact on the reduction of smoke temperature than installation number of ventilation vents. Smoke temperatures computed for all scenarios except for scenario No. 1 (without ventilation vent) and scenario No. 6 (with multiple fire sources) above fire source are analyzed to be under $400^{\circ}C$ and it means that the radiation of smoke layer above fire source doesn't induce the ignition of materials around fire source.

자연환기 설계의 이론과 실제

  • 노지웅
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.44-46
    • /
    • 2000
  • 자연환기를 건물에 적용하는 주된 목적은 "실내 환경수준을 충족시키기 위해 필요한 초기투자 및 유지비용을 절감하기 위해서" 이다. 따라서, 합리적인 환경계획을 수립하기 위해서는 "자연환기를 적용하는 것이 유효한가\ulcorner 유효하다면 어떤 전략을 채용할 것인가\ulcorner" 하는 것이 계획단계에서 반드시 검토되어져야 한다. 설계자는 합리적인 판단을 위해서 다양한 정보를 필요로 하게되며 이 과정에서 다양한 해석도구가 이용될 수 있다. 본보에서는 자연환기 설계단계에서 요구되는 각종정보와 그 해석도구의 특성에 대하여 고찰해 보고자 한다.

  • PDF

환기용 부스 설계 최적화 검증

  • Jang, Ho-Jun
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.85-89
    • /
    • 2016
  • 실제 환풍용 팬의 수치를 이용하여 환기용 부스의 형상에 대한 내부 유동의 변화 양상과 유동의 정상상태에 따른 해석결과 비교를 수행하였다. 벽면이 기울어진 형상이 직사각형 형상의 부스에 비해 나은 내부 흐름을 보여 환기용 부스에 더 적합한 형상임을 확인할 수 있었다. 비정상 유동과 정상 유동은 해석 결과에서 다소 차이를 보였으며, 이는 차후 실험을 통해 검증할 예정이다.

  • PDF

A study on the ventilation characteristics and design of transverse ventilation system for road tunnel (도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.305-315
    • /
    • 2018
  • In this study, the ventilation characteristics and the relationships between the required ventilation flow rate and the ventilation system flow rate was investigated by numerical method for the optimum design of the transverse ventilation and semi-transverse ventilation system in road tunnels. The following results were obtained. In supply exhaust transverse ventilation system, the system supply-exhaust air flow rate is theoretically equal to the difference between the required ventilation flow rate and natural ventilation flow rate. However, it is shown that it increases by about 10% in the analysis results. And, in the case of the longitudinal air flow rate is increased by installed jet fans, ventilation system air flow rate is reduced. However, as the longitudinal air flow rate increases, the concentration of pollutants in the tunnel decreases, so the exhaust effect of pollutants decreases, and the effect of reducing the system air flow rate is decreased. In case of semi-transverse with only air supply, ventilation system air flow rate is equal to required ventilation air flow rate when tunnel inlet velocity is negative, but results is shown it is increased within about 13.3%. Also, it was found that ventilation effect can not be expected even if the jet fans are increased when the tunnel inlet velocity is negative.

On the Consideration of CO and Soot Yield Concept in FDS Fire Field Model (FDS 화재해석 모델에 적용된 CO와 연기 생성율 개념에 대한 고찰)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.93-99
    • /
    • 2009
  • 본 연구는 ISO-9705 표준화재실의 40% 축소모형실험 결과와 FDS 화재해석 결과의 비교분석을 통하여 FDS 화재해석 모델에 적용된 CO 와 soot의 생성율(yield rate)에 기초한 접근방식의 타당성을 검토한다. 일반적으로 생성율은 연료적인 특성인 동시에 공간의 환기조건이나 열적조건등에 영향을 받게 된다. 그러나 FDS 해석에 적용되는 연료의 생성율은 환기량이 충분한 상태(well ventilated condition)에서 측정되어진 물성으로써 공간내부의 CO와 soot 농도는 연료의 종류와 화원의 크기에 의해서만 결정된다. 따라서 환기조건과 연료특성에 따른 화재공간 내부에서의 CO와 soot 농도를 측정하여 이 결과를 FDS 시뮬레이션 결과와 직접 비교함으로써 환기조건 및 연료종류에 따른 CO 와 soot의 생성율 개념의 타당성을 고찰해보고자 한다.

  • PDF

A Study on Distribution of Smoke Temperature in a Road Tunnel with Scenarios (시나리오에 따른 터널 내 연기 온도 분포 특성에 관한 연구)

  • Ju, Eun-Hye;Yoon, Yong-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.160-161
    • /
    • 2013
  • 환기구의 유무, 환기구 설치 대수, 환기구 용량 등을 변수로 한 5개의 시나리오를 가정하여 터널내 연기 온도 분포의 특성을 분석하였다. 해석 결과 환기구의 설치 대수를 증가시킴에 따라 연기 온도는 감소하였으며, 환기구가 2대에서 3대로 증가하는 경우 온도 감소 효과는 크지 않은 것으로 나타났다. 환기구의 용량을 증가시키는 경우 환기구를 설치하는 것과 유사한 온도 감소 효과를 나타내었다.

  • PDF

A Numerical Study on Characteristics of Smoke Exhaust in Road Tunnel Fires for Different Ventilation System (터널 화재 시 환기 방식에 따른 배연 특성의 수치해석 연구)

  • Kim, Jong-Yoon;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.201-207
    • /
    • 2008
  • In this study, three Dimensional CFD simulations were carried out to investigate the effective smoke extraction system in bi-directional road tunnel fires using FLUENT. Characteristics of transverse system with big size extraction port or with uniform extraction port, semi-transverse system and longitudinal system for smoke extraction system were analyzed. Air velocity, port size, and operating method were used with variable. Distributions of smoke spread, CO was analyzed. As a result, the transverse ventilation system with big size port was found to be more effective than the uniform ports for bi-directional road tunnel.

3-dimensional Numerical Analysis on Thermal Performance of an Oil Cooler (3차원 오일쿨러 방열성능 수치해석)

  • Park, Sang-Jun;Lee, Young-Lim
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.944-946
    • /
    • 2010
  • 열교환기는 공조 및 기타 산업현장에서 많은 수요가 창출되고 있는데 본 논문에서는 3차원 수치해석을 이용하여 수송기계의 오일쿨러나 연료쿨러에 쓰이는 전형적인 열교환기에 대한 방열 성능을 해석하였다. 열교환기의 핀 타입 중 wavy 및 louver에 대하여 열교환기 성능 실험 데이터를 이용하는 3차원 열교환기 모델을 완성하고 통과 풍량에 따른 열교환량을 예측하였다. 이는 열교환기를 통과하는 풍속이 균일하지 않을 때 열교환량을 예측할 수 있어 설계 정확성 향상에 기여할 수 있다.

  • PDF