• Title/Summary/Keyword: 환기 냉방기

Search Result 43, Processing Time 0.022 seconds

Experimental Study on Performance Characteristics of Air-Conditioner with PF Heat Exchanger (PF 열교환기 적용 공조기 성능특성에 관한 실험연구)

  • Park, K.M.;Um, U.S.;Kwon, Y.C.;Chang, K.S.;Lee, S.J.
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.893-896
    • /
    • 2009
  • 본 연구에서는 공조용 실외기의 고효율화 및 소형화를 위해 응축기로 사용되고 있는 핀-관 열교환기를 동일한 전면면적의 PF 열교환기로 변경하여 성능변화 및 특성을 조사하였다. 이를 위해 3종의 PF 열교환기를 적용하여 공조기의 성능을 비교평가 하였다. 실험은 공기 엔탈피식 칼로리미터에서 공조기의 냉방능력과 소비전력을 측정하여 COP를 계산하였다. PF 열교환기를 적용한 경우에 핀-관 열교환기보다 냉방능력은 증가하고 소비전력은 감소하여 COP가 향상되었다. PF 열교환기의 핀 피치가 클수록 냉방능력과 COP는 감소하였다.

  • PDF

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger (PF 열교환기를 적용한 공조기의 성능 비교 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.470-475
    • /
    • 2009
  • In the present study, the heat transfer characteristics of the fin-tube and PF heat exchangers and the performances of the air-conditioner are experimentally investigated. Also, Cooling Seasonal Performance Factor(CSPF) of the air-conditioner is evaluated. For the heat exchanger experiment, the heat transfer and pressure drop are obtained. For the air-conditioner experiment, the cooling capacity, input power and COP are obtained. The air-enthalpy calorimeter and the constant temperature water bath are used. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. PF heat exchanger has smaller refrigerant weight and larger capacity and COP than the fin-tube heat exchanger. The performance of PF-2 heat exchanger with the squarer fin is more excellent than that of PF-1 heat exchanger with the triangler fin. Also, CSPF of the fm -tube and PF heat exchanger is evaluated.

Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler (재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석)

  • Chang, Y.S.;Lee, D.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.

Improvement of Cooling Efficiency in Greenhouse Fog System Using the Dehumidifier (제습기를 이용한 온실 포그냉방시스템의 효율향상)

  • Nam Sang Woon;Kim Kee Sung;Giacomelli Gene A.
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • In order to provide fundamental data on utilization of dehumidifier in greenhouses, a condensing type dehumidifier using ground water as a coolant was developed and tested dehumidification performance. The developed dehumidifier was applied to greenhouse with fog cooling system and effect of dehumidification on improvement of evaporative cooling efficiency was analyzed. Results of the dehumidifier performance test showed that dehumidification using ground water as a coolant was sufficiently possible in fog cooling greenhouse. When the set point temperature of greenhouse cooling was $32^{\circ}C$ and as temperatures of ground water rose from $15^{\circ}C\;to\;18^{\circ}C,\;21^{\circ}C\;and\;24^{\circ}C$, dehumidification rates decreased by $17.7\%,\;35.4\%\;and\;52.8\%$, respectively. As flow rates of ground water reduced to $75\%\;and\;50\%$, dehumidification rates decreased by $12.1\%\;and\;30.5\%$, respectively. Cooling efficiency of greenhouse equipped with fog system was distinctly improved by artificial dehumidification. When the ventilation rate was 0.7 air exchanges per minute, dehumidification rates of the fog cooling greenhouse caused by natural ventilation were 53.9%-74.4% and they rose up to 75.4%-95.9% by operating the dehumidifier. In case of using the ground water of $18^{\circ}C$ and flow rate of design condition, it was analyzed that whole fog spraying water can be dehumidified even if the ventilation rate is 0.36 exchanges per minute. As a utilization of dehumidifier, it is possible to improve cooling efficiency of fog system in naturally ventilated greenhouses.

태양열을 이용한 냉방장치 -급수식 냉동기를 중심으로-

  • 하재현;이상천
    • Journal of the KSME
    • /
    • v.17 no.1
    • /
    • pp.23-27
    • /
    • 1977
  • 태양열을 냉방에 이용하기 위한 시스템은 집열기,열교환기,냉동기 등으로 구성된다. 집열기는 난 방시와 마찬가지로 볼 때 냉난방을 병용하는 집열기를 사용하면 유리하다. 열교환기는 집열기에 서 수집한 열을 냉방기에 전달시키는 기능을 가지는데 용도에 따라 이것을 사용하지 않는 경우도 있다. 냉동기로는 보통 흡수식 냉동기를 사요하나 그외 개방식, 분사식 등의 냉동기도 사용된다. 그러나 분방식 냉동기는 취급은 용이하나 흡수제의 재생조건이 까다로워 높은 습기를 갖는 경우 재생온도가 역시 높아져야 하므로 우리나라의 경우에는 여름철의 습도가 높기 때문에 재생온도가 높아져야 하므로 태양열 냉방에는 부적당하다. 또 분사식 냉동기의 경우 성적계수(Coefficient of Performance) 가 다른 냉동기에 비해 낮고 증기압력이 낮으면 이것이 극히 낮아지기 때문에 태양 열 냉방에 많이 사용하지 않는다. 그래서 태양열 냉방에 있어서 냉동기는 거의 흡수식을 사용하 고 있으며, 여기에서도 주로 흡수식 냉동기를 사용한 냉방에 대하여 논하고져 한다.

  • PDF

Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System (일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.176-181
    • /
    • 2011
  • The fan and pad evaporative cooling system is one of the main cooling methods in greenhouses. Its efficiency is very high, but it has some disadvantages as temperature gradient in greenhouse is large. This study was conducted to reduce the internal temperature gradients in the fan and pad cooling greenhouses. Experiments on cooling performance were carried out in a greenhouse equipped with air duct and integrated fan and pad system as an idea of this study. It showed that the cooling efficiency of an integrated fan and pad system was 75.7% in the first stage and 88.6% in the second stage. When this cooling system was operated for an unshaded and a shaded greenhouse, there were cooling effects of $5.7\sim7.6^{\circ}C$ and $7.4\sim9.7^{\circ}C$ to the control greenhouse, respectively. Maximum temperature differences in a cooling greenhouse, with a length of 18m, were $1.6\sim1.7^{\circ}C$ for shaded conditions and $2.3\sim2.7^{\circ}C$ for unshaded conditions. This greenhouse cooling method, with air duct and integrated fan and pad system, can reduce about 40~50% of the internal temperature gradients in the usual fan and pad cooling greenhouses.

A Study on the Characteristics of Plate Finned-Tubes Evaporator (평판핀이 부착된 증발기의 특성에 관한 연구)

  • 손병진;민묘식;김홍배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.982-991
    • /
    • 1991
  • 본 연구에서는 냉방기에서 널리 이용되고 있는 평판핀이 연속적으로 부착된 다관식 증발 열교환기에 대하여 (1) 냉매의 열역학적 물성치의 변화 (2) 냉매와 공기 측 열전달 계수의 변화 (3) 냉매측 관 마찰 손실등을 고려한 시뮬레이션 프로그램을 작성하고 그 결과를 실험을 통하여 보정 완성하였다. 계산결과로 부터 공조기기의 설계조건, 공조계통 해석을 위한 기초자료를 제시하였다.

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

Natural Ventilation Effect of Bending Panel Type Windows in Greenhouse (굴절패널방식 환기창의 자연환기 효과)

  • Lee, Si-Young;Kim, Jin-Young;Kim, Hyun-Hwan;Jeon, Hee
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.71-74
    • /
    • 2000
  • 일반적으로 온실은 저온기에는 보온이나 난방을 하면서 적극 사용하고 있으나 고온기에는 냉방에 소요되는 에너지가 난방에 비해 상대적으로 많이 소요되므로 온실의 활용도가 떨어지게 된다. 자연환기 시스템은 에너지를 사용하지 않거나 최소한으로 줄여 온실내 온도를 최소한 외부와 동일하게 하거나 낮게 하기 위한 장치라고 할 수 있다. 자연환기를 위한 환기창으로 유리온실이나 경질판 온실과 같은 양지붕형 온실에서는 측창으로 3Way방식이나 권취식, 프로젝트방식 등 다양한 환기창을 사용하고 있으나 천창은 주로 온실 길이방향의 연속형 창틀을 랙앤피니언이나 X형 개폐암으로 개폐하는 프로젝트 방식을 많이 사용하고 있다. (중략)

  • PDF