• Title/Summary/Keyword: 환기회수

Search Result 145, Processing Time 0.023 seconds

A Study on Composition and Utilization of Waste Heat Recovery System Assuming Aerobic Liquid-composting Fermentation heat (호기성 액비화 발효열을 가정한 폐열회수시스템 구성 및 활용 연구)

  • Lim, Ryugap;Jang, Jae Kyung;Kang, Taegyung;Son, Jinkwan;Lee, Donggwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.56-66
    • /
    • 2021
  • In this study, a waste heat recovery system was devised and the performances of components incorporated to recover the heat generated during the processing of aerobic liquid-composting in a livestock manure treatment facility were analyzed. In addition, the availability of recovered heat was confirmed. The heat generated by liquid fermentation in the livestock manure treatment facility was also checked. Experimental temperatures were set at 35, 40, and 45 ℃ based on considerations of the uniformity of aerobic liquid-composting fermentation tank temperature and its operating range (34.5 ~ 43.9 ℃). Recovered heat energies from the combined heat exchanger, which consisted of PE and STS pipes, were 53.5, 65.6, 74.4 MJ/h, The heat pump of capacity 5 RT was heated at 95.6, 96.1, 98.9 MJ/h and the heating COPs of the pump were 4.53, 4.62, and 4.65, respectively. The maximum hot water production capacity of the heat exchanger assuming a fermentation tank temperature of 45 ℃ confirmed an energy supply of 56 360 kcal/day. The heating capacity of the FCU linked to the heat storage tank was 20.8 MJ/h, and the energy utilization efficiency was 96.1%. When livestock manure was dried using the FCU, it was confirmed that the initial function rate was reduced by 50.5 to 45.8 % after drying.

시설원예 준비와 관리대책 - 하우스의 형태$\cdot$자재 및 환경관리

  • 이창환
    • The Bimonthly Magazine for Agrochemicals and Plant Protection
    • /
    • v.7 no.5
    • /
    • pp.107-115
    • /
    • 1986
  • 시설원예라 함은 프라스틱하우스, 유리온실과 같은 시설안에서 작물을 주위의 불량한 환경조건에서 보호하는 동시에 생력화할 수 있는 장치를 도입하여 자본집약적으로 원예작물을 재배하고 비수기에 생산물을 공급하여 농가소득을 향상하고 국민식생활 개선에 기여할 수 있는 재배형식이다. 우리나라는 북반구에 위치하여 4계절이 뚜렷하고 동계에는 기온이 매우 낮아 적당한 보호조치 없이는 작물을 재배할 수 없다. 즉 시설원예는 동계 저온기의 작물생산이 주가되므로 보온 및 기온이 중요하고 또 동계에는 일조시간이 짧고 광도가 낮아 일사량이 부족하며 시설내에서는 더욱더 부족하게 되므로 광선관리에 신경을 쓰지 않으면 안된다. 그리고 고정된 하우스내에서 작부회수를 증가시키고 재식밀도를 높이게 되면 자연 다비재배를 해야하므로 염류농도의 장해와 가스 피해가 우려된다. 또한 환기불량으로 인한 탄산깨스의 부족과 다습으로 인한 병해의 발생이 심한 점이 있으므로 적절한 준비와 관리대책을 세우지 않으면 안된다.

  • PDF

Waste Heat Recovery by Heat Pipe Heat Exchanger in Spray Dryer (분무건조장치에서의 히트파이프식 열교환기의 폐열회수)

  • 박기호;이기우;박준택;이계중;임상근
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.193-198
    • /
    • 2000
  • 분무건조장치는 Solution, Slurry, Emulsion, Colloidal Suspension 등의 액상원료를 미립화하여 표면적을 증가시켜 수열면적을 크게 하여 열풍과 직접 접촉함으로써 순간적으로 건조를 행하여 액상원료로부터 바로 분립상의 제품을 얻는 건조법이다. 분유를 비롯하여 Instant 식품류, 합성세제, 염료, 안료, Ceramic, 공해 폐액의 처리에 이르기까지 폭넓게 이용되고 있다. 분무건조기는 통기, 회전, 기류 건조기 등 다른 건조기에 비하여 고도의 설계 및 제작 기술을 요하며, 설계에 있어서 일부 이론적인 취급이 행해지고 있는 것은 사실이나 아직은 경험에 의존하고 있는 현실이다. 국내에서 제작되고 있는 분무건조기의 열효율은 25-33%로 선진국의 35-48%에 비해 매우 낮다. 국내에서 사용되고 있는 분무건조기의 92%는 덴마크, 일본 등에서 수입된 것이다.(중략)

  • PDF

A study on the performance enhancement for combined cycle using cold heat of LNG (LNG 냉열을 이용한 복합사이클 발전시스템의 성능개선연구)

  • 김용희;김병일
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.77-80
    • /
    • 1996
  • 우리나라에서 피크부하용으로 사용하는 복합발전이 하계시에서 외기온도가 상승함에 따라 실제로는 정격출력을 내지 못하고 있다. 따라서 본 연구에서는 연료(LNG)의 냉열을 이용하여 가스터빈의 연소용공기를 냉각시킬 경우, 복합발전 시스템의 성능변화를 분석하기 위하여 시뮬레이션을 수행하였다. 그 결과 LNG의 냉열을 이용하여 연소용공기를 원하는 온도까지 냉각시킬 수 있음을 확인할 수 있었다. 또한 연소기로 연료를 투입하기전에 설계온도까지 예열시키는 열교환기를 통해 배기가스에 함유된 현열을 더욱 많이 회수하면서, 가스터빈 투입연료의 온도를 상승시킬 수 있어, 시스템효율이 더욱 상승함을 알 수 있었다. 결론적으로 외기온도가 변하는 경우에, 본 시스템의 도입을 위해서는 경제성분석과 더불어 열교환기 시스템의 최적합성이 추후 진행되어야 할 것이며, 이를 통해 최적의 발전시스템을 구성할 수 있으리라 생각된다.

  • PDF

Studies on spinach growth reaction and analysis of heat balance to control air temperature in greenhouse at summer season. (1) Maximum requirement number of air changes to set point of inside air temperature according to region in greenhouse (여름철 하우스 온도환경제어를 위한 열수지분석과 시금치생육 반응연구에 관한 연구. (1)지역별 목포온도에 따른 최대 소요환기회수)

  • 우영회;김형준;남윤일;권영삼;송천호;김동억
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.04a
    • /
    • pp.60-63
    • /
    • 1995
  • 우리나라 기상여건을 고려하여 온실의 여름철 고온에 대한 체계적인 연구는 아직 미비한 상태이며 거의 이루어지고 있지 않다. 더우기 많은 자본과 기술이 투자된 현대화 하우스에서 여름철 고온화현상에 대처하는 재배기술부족으로 7, 8월 2개월간 작물을 재배하지 못하고 대부분 휴작을 하므로서 시설의 주년이용과 고도활용에 심각한 문제점으로 대두되고있으며 온실의 주년재배를 위한 여름철의 하우스환경의 적정화연구는 온실재배의 당면과제라 할수 있다. (중략)

  • PDF

Numerical Analysis of Wasted Heat Recovery Ventilator for Improving the Heat Exchange Efficiency (폐열회수 환기장치의 열교환 효율 개선을 위한 전산수치해석)

  • Kim, Hyun-Il;Kim, Jae-Sung;Park, Chul-Woo;Park, Kyung-Seo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • In this paper, we performed numerical analysis to improve the heat exchange efficiency of wasted heat recovery ventilator which has a delivery and a exhaustion fan. One of the most important design factors that affect the efficiency of heat exchange is uniform counter-flow between inbound and outbound air flows. We had simulated several types of porous plates which were installed at air intake area. With plate having 45 degrees of installation angle and 15 mm diameter holes which are uniformly arranged, we can generate a uniform air flows at the area of porous media where inbound and outbound air flows are cross over. In addition, we installed a duct to reduce vortex flows at the outlet and to discharge exhaust airs rapidly. By using the proposed numerical assessment, we expect the improvement of the heat exchange efficiency of ventilator.

An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger (전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구)

  • Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

Experimental Study on Naphthalene Heat Pipe Heat Exchanger for Middle-high Temperature Heat Recovery (중고온 범위 폐열회수용 나프탈렌 히트파이프 열교환기에 대한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Hwang, Seon-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.64-69
    • /
    • 2007
  • This study is to develop heat recovery system using high performance heat pipe heat exchanger for Middle-high temperature range industrial exhaust gas. The naphthalene is used as working fluid of heat pipe in this study. Single naphthalene heat pipe could transport over 2,000 watts with $0.05^{\circ}C/W$. The heat pipe heat exchanger consist of 50 naphthalene heat pipes recovered 62 kW when over $400^{\circ}C$ gas exhausted and the maximum recovered heat rate was 173 kW in this study.

  • PDF

A Study on the Improvement of Efficiency of Heat Transfer on the Heat Recovery Ventilator with Rotating Porous Disk (로터리형 폐열회수 환기장치의 열전달 성능 향상에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1352-1357
    • /
    • 2014
  • In the present study, the heat transfer performance on the heat recovery ventilator with rotary disk were experimentally investigated. The temperature of entrance and exit of the heat recovery ventilator, air flow distribution of high temperature air and low temperature air, heat flux and the overall heat transfer coefficients are estimated from the experimental results. As the number of revolution of rotary disk, the air flow distribution increase, heat flux and overall heat transfer coefficients increase.

Improvement of Energy Efficiency in Wood Frame House with Energy Efficient Methods (건물 에너지 절약요소 적용을 통한 목조주택의 에너지 성능 개선)

  • Kim, Sejong;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.77-86
    • /
    • 2013
  • This research was carried out to evaluate and raise the energy efficiency of wood frame house. The commercial solution program CE3 (Construction Energy Efficiency Evaluation) was used for simulating the energy consumption in the single-family wood frame house. The results showed that the annual heating energy demand of the house was 160 kWh per 1 $m^2$ floor area. In order to decrease the heating energy demand, the following energy efficiency methods were applied to the simulation : a) simplification of building shape, b) decrease of windows area, c) application of high performance windows (with low thermal transmittance) and d) application of heat recovery ventilator. In case of replacement of the windows with high performance one with thermal transmittance 1 $W/m^2{\cdot}K$, the lowest heating demand of 80 $kWh/m^2{\cdot}a$ was obtained. The best combination of methods, application of high performance windows and heat recovery ventilator, showed heating energy demand 34.5 $kWh/m^2{\cdot}a$.