• Title/Summary/Keyword: 환기저항계수

Search Result 18, Processing Time 0.021 seconds

The Estimation and Application of Optimum Design Variables for Road Tunnel Ventilation System Based on Statistical Analysis (통계적 분석을 이용한 터널 환기시스템 적정설계변수의 산정 및 적용에 관한 연구)

  • 이보영;유용호;김진
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • In this study, the emission rate of pollutant was modified according to the published standards, and the distribution of pollutant concentration was analyzed for each vehicle velocity. This modified emission rate was applied to a model tunnel and it was proved that the required air quantity was reduced to 49%, compared to the PIARC method. From the simulation result, it was proved by using statistics that the most sensitive factor among them is the friction coefficient and it was modified to the value in the range of 0.018 to 0.021. It is also expected that the required air quantity can be decreased form 14.4% to 19.2% according as the coefficient is applied to the domestic model tunnels. In conclusion, it is proposed that the number of jet fans can be reduced and the annual operating cost can be curtailed as well.

Development of a programming logic to estimate the wall friction coefficient in vehicle tunnels with piston effects (교통환기력이 작용하는 터널 내 벽면마찰계수 추정을 위한 프로그램 로직 개발)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Young-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.39-53
    • /
    • 2018
  • Generally, the total ventilation resistance coefficient in a tunnel consists of inlet/outlet loss coefficient, wall friction coefficient, and other loss coefficient caused by sudden expansion and contraction of cross-section, etc. For the tunnel before opening, when the running ventilation fan is stopped, the wind speed in the tunnel is reduced by the total ventilation resistance drag. The velocity decay method is comparatively stable and easy to estimate the wall friction coefficient in the pre-opening tunnel. However, the existing study reported that when the converging wind speed is a negative value after the ventilation fan stops, it is difficult to estimate the wall friction coefficient according to the velocity decay method. On the other hand, for the operating tunnel in which the piston effect acts, a more complex process is performed; however, a reasonable wall friction coefficient can be estimated. This paper aims at suggesting a method to minimize the measurement variables of the piston effect and reviewing a method that can be applied to the operating tunnel. Also, in this study, a new method has been developed, which enables to calculate an variation of the piston effect if the piston effect is constant with a sudden change of external natural wind occurring while the wind speed in the tunnel decreases after the ventilation fan stops, and a programming logic has been also developed, which enables dynamic simulation analysis in order to estimate the wall friction coefficient in a tunnel.

원자력 발전용 직교류 핀-관 열교환기의 성능 평가

  • 김정훈;배성원;김무환;허용석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.279-285
    • /
    • 1997
  • 본 연구에서는 나선형과 판형의 핀을 가진 원자력 발전소용 직교류 핀-관 열교환기의 열량을 ARI Standard-410에 따라 실험적으로 측정하여 풍속과 냉수속에 따른 열저항 및 압력 손실을 도출하는 것을 목적으로 하였으며, 이러한 시도를 통해서 실제 열교환기의 성능 평가시 필요한 기술적 자료를 축적하고자 하였다. 실험에서는 나선형 6fin/in, 8fin/1n, 10fin/in 열교환기와 판형 8fin/in 열교환기를 사용하였으며, 풍속을 0.486m/s와 2.214m/s로, 수속을 1m/s~4m/s로 하여 실험을 행하였다. 실험 결과를 통하여, 원자력 발전소의 격납 용기내의 공기조화를 위하여 사용되어 지는 열교환기의 성능 평가 방법 및 실증 능력을 확보하였으며, 풍속 증가에 따라 총괄 열전달 계수는 전체적으로 비례 증가하는 경향을 보였다. 판형이 나선형 보다 열전달 계수가 작게 나타났으며, 나선형 열교환기의 경우 fin수에 따른 변화는 크지 않았으나, 열전달 면적을 고려한 경우에는 나선형 10fin/in 열교환기가 가장 뛰어난 열교환 성능을 발휘함을 알 수 있었다. 또한, 공기측의 압력 손실은 전체적으로 전연 풍속 증가에 따라서 속도 제곱에 비례하여 증가하는 경향을 보였다.

  • PDF

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

A Study on Vehicle Drag Coefficients in Domestic Road Tunnels (국내 도로터널내 차량항력계수 관련 연구)

  • Lee, Chang-Woo;Lee, Kyeong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • Drag coefficient is one of the critical design factors to quantify the piston effect in vehicle tunnels. Several problems are raised on the drag coefficient currently applied for the ventilation system design; unverified adoption of the projected frontal area of the vehicle from the foreign study in the past, and lack of consideration for the slip-streaming effect. This study aims at better estimation of the traffic-induced ventilation force in the local tunnels. Values for the projected frontal area of the vehicles running on the local roads at present are proposed and results of an extensive CFD study are studied on the slip-streaming effects in various traffic conditions to quantify $K_{blockage}$ and the drag coefficient in the domestic tunnels.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

Study on the Hydraulic and Thermal Characteristics of Metallic Porous Medium (다공성 금속의 수력 및 열 교환 특성에 관한 연구)

  • Jin, M.H.;Kim, P.H.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.54-58
    • /
    • 2008
  • 최근 열교환기의 향상을 위해 발포다공성매체의 적용이 증가하고 있다. 열교환기의 적용에 있어서 발포다공성매체의 이점을 살펴보기 위해 본 연구에서는 2가지 실험을 수행하였다. 첫 번째는 수력의 관점에서 투과계수 및 내부계수를 결정하는 것이고, 두 번째는 열교환의 관점에서 다공성매체의 유효전도율을 측정하는 것이다. 본 실험에서는 기공도는 거의 같으나 기공의 크기가 각각 20 ppi와 40 ppi인 구리 다공성매체를 사용하였다. 실험의 결과는 40 ppi 크기의 다공성매체가 수력과 열교환, 두가지 관점 모두에서 보다 높은 저항 효율을 나타낸다는 것을 보여준다.

  • PDF

Numerical Study for Air-Side Flow Characteristics of Fin-Tube Heat Exchangers with Oval-Tube (타원관형 핀-관 열교환기의 공기측 열유동특성에 대한 수치해석)

  • 김승택;최윤호;김형택
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.166-175
    • /
    • 2001
  • 핀-관 열교환기의 효율을 증대시키기 위하여는 열저항을 결정하는데 있어서 중요한 역할을 하는 공기측 열전달 특성의 향상이 필요하다. 본 연구에서는 슬릿핀과 같은 핀 형상의 개선으로 인한 높은 압력손실을 감소시키기 위하여 타원관형 열교환기를 고려하였으며 이를 자체 개발한 3차원 비압축성 Navier-Stokes 코드를 이용하여 공기측 성능을 해석하였다. 이 코드는 시간항에 스칼라 내재적 근사분해법(scalar implicit approximate factorization)절차, 공간항에 유한체적법과 2차의 풍상차분법을 사용한다. 핀 형상이 평판핀인 타원관에 대하여 세장비가 0.3, 0.5, 0.75인 경우와 핀 형상이 슬릿핀이고 세장비가 0.5인 타원관에 대하여 공기측 유동을 해석하였으며 이를 원관의 성능과 비교하였다. 평판핀의 경우, 압력강하량은 원관과 비교하여 세장비가 작아질수록 감소하는 것을 볼 수 있었으며, 열전달 계수는 고려한 유입속도 범위에서 원관을 기준으로 약 5%이하의 변화로 거의 동일하게 유지되는 것을 볼 수 있었다. 슬릿핀의 경우 역시 문제되는 높은 압력강하량은 타원관을 도입함으로써 효과적으로 낮출 수 있음을 볼 수 있었다.

  • PDF

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (1) Study on Aerodynamic Resistance of Tomato Canopy through Wind Tunnel Experiment - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (1) 풍동실험을 통한 토마토 식물군의 공기저항 연구 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Lee Seung-Kee;Kwon Soon-Hong
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.289-295
    • /
    • 2006
  • A computational fluid dynamics (CFD) numerical model has been developed to effectively study the ventilation efficiency of multi-span greenhouses with internal crops. As the first step of the study, the internal plants of the CFD model had to be designed as a porous media because of the complexity of its physical shapes. In this paper, the results of the wind tunnel tests were introduced to find the aerodynamic resistance of the plant canopy. The Seogun tomato was used for this study which made significant effects on thermal and mass exchanges with the adjacent air as well as internal airflow resistance. With the main factors of wind speed, static pressure, and density of plant canopy, the aerodynamic resistance factor was statically found. It was finally found to be 0.26 which will be used later as an input data of the CFD model. Moreover, the experimental procedure of how to find the aerodynamic resistance of various plants using, wind tunnel was established through this study.