• Title/Summary/Keyword: 화재 연기

Search Result 767, Processing Time 0.031 seconds

Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires (고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구)

  • 이지희
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.59-79
    • /
    • 2001
  • The paper proposes alternatives for fire safety in architectural planning through heat-smoke distribution related to openings so that we decrease casualty and property loss by fire and lay a great emphasis on building high-rise apartments with consideration of fire safety in Korea. An analysis program(HFA-Heat Fluid Analysis) is built to perform simultaneously numerical analysis and experimental analysis on rooms, units and buildings. In consequence, on the first, fire prevention methods are required to be set up related to openings for design rooms since the flow of heat and smoke is influenced by the type of openings in high-rise apartments. Second, the numerical analysis showed that different planning types cause to show differences in the spreading time of heat and smoke to design the units of high-rise apartments. On the third, each unit building showed different fire behavior depending on openings by numerical analysis and small scaled experiment on heat and smoke flow.

  • PDF

Safety Evaluation of Tunnel Fire by CFD Modeling (터널화재의 CFD Modeling에 의한 안전성 평가방법)

  • Lee, Chang Wook;Lee, Keun Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.84-84
    • /
    • 2011
  • 터널화재의 위험요소에 대한 해석을 위해서는 실제 상황을 재현한 실대형 실험이 가장 유용하겠지만 현실적으로 시간적, 공간적, 경제적인 제약이 따르기 때문에 CFD Modeling 기술의 이용 및 검증이 필요하고, 실제 상황에 가까운 현상의 재현을 위해서는 시뮬레이션의 정확도에 대한 향상이 필수적이다. 또한, CFD Modeling을 터널화재에 적용할 때 시뮬레이션의 질에 영향을 미칠 수 있는 요소들에 대한 결정이 선행되어야 한다. 우선, 터널의 기하학적 구조와 경계조건의 확립이 필요한데 필요한 정보를 얻기 위해서 어느정도 길이의 터널이 적절한지에 대해 생각할 필요가 있으며, 단면변화에 대한 결정을 통해 모델링을 수행하여야 한다. 모델링 작업이 선행된 후에 화재의 위치, 성장률, 최대 크기, 환기시스템 사항 등의 고려가 필요한데 이러한 조건들은 CFD Modeling의 결과에 직접적인 영향을 주기 때문에 충분한 사전조사가 이루어져야 하고, 각 사항들의 변수를 고려하여 다양한 화재시나리오의 도출이 가능할 수 있다. 마지막으로, 화재에서 발생된 열중 약 30%가 복사에 의해 주위 벽으로 전달될 수 있고 열은 연기가 가득찬 영역내에서 재분배될 수 있는데, 열전달 및 연기의 유동 등에 관한 자료를 기초로 화재현상에 대한 분석이 가능하다. 이러한 과정들을 통해 실제 상황에 가까운 설계화재 시나리오를 예측할 수 있다. 본 연구에서는 우리나라 최장대터널인 죽령터널에 대해 합리적인 가정을 통한 설계화재 시나리오를 기초로 화재시뮬레이션은 FDS(Fire Dynamics Simulator) 프로그램을 사용하여 화재 및 연기의 이동 양상을 분석하고, 피난시뮬레이션은 SIMULEX 프로그램을 사용하여 피난시간을 예측 함으로써 터널화재의 CFD Modeling에 의한 피난안전성을 검토하고자 한다.

  • PDF

Smoke Mass Concentration의 측정에 의한 난연제의 난연 특성 평가

  • 송영호;정국삼
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.180-183
    • /
    • 2003
  • 최근 화재 발생시 화재의 열적 영향에 의한 인명 피해보다 연기 발생에 따른 피난로의 미확보, 독성 가스의 발생에 따른 질식사고에 의한 인명 피해가 급증하고 있다. 건물 내 화재시 발생되는 다량의 연기 및 독성 가스는 건물 내의 거주자의 피난을 방해하여 인명 피해의 중요 원인이 된다.(중략)

  • PDF

Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions (다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정)

  • Goo, Jaehark;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.8-15
    • /
    • 2017
  • Most fire victims succumb to smoke inhalation, and fire smoke toxicity from interior materials is increasing with increased use of plastics. Large amounts of hazardous effects of smoke are related to deposition of smoke particles in respiratory tracts, and deposition characteristics are influenced by size distribution of particles. Thus, it is essential to know the size distribution of smoke particles from plastics for hazard analysis of fire smoke. In a recent study, it has been shown that size distributions of smoke particles from PP are different from wood in many aspects. In order to know whether other plastics show the same characteristics as PP, size distributions of smoke particles from four plastic materials (LDPE, PA66, PMMA, and PVC) were measured in real time under each fire type with various temperature and oxygen supply. In this study, smoke particles from different plastics were generated uniformly by using steady-state tube furnace method provided in ISO/TS 19700. Their size distributions were measured by using an electrical low pressure impactor (ELPI). Results of measurements showed that size distributions of smoke particles from these four plastic materials were similar to those from PP in many aspects. However, they were distinctively different from those of wood.

A Study on the Comparison of Aspirating Smoke Detector and General Smoke Detector Detection Time according to the Fire Speed and Location of Logistics Warehouse through FDS (화재시뮬레이션을 통한 물류창고 화재 속도와 위치에 따른 공기흡입형 감지기와 일반 연기 감지기 감지시간 비교에 관한 연구)

  • SangBum Lee;MinSeok Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.608-623
    • /
    • 2023
  • Purpose: Recently, the number of logistics warehouses has been on the rise. In addition, as the number of such logistics warehouses increases, number of fire accidents also increases every year, increasing the importance of preventing fires in large logistics warehouses. Method: investigated aspirating smoke detectors that are emerging as adaptive fire detectors in logistics warehouses. Then, through fire simulation (FDS), logistics warehouse modeling was conducted to compare and analyze the detection speed of general smoke detectors and aspirating smoke detectors according to four stages of fire growth and three locations of fire in the logistics warehouse. Result: Growth speed in Slow-class fires and Mediumclass fires, the detection speed of aspirating smoke detectors was faster regardless of the location of the fire. However, in Fast-class fires and Ultra-Fast-class fires, it was confirmed that the detection speed of general smoke detectors was faster depending on the location of the fire. Conclusion: It was confirmed that the detection performance of the aspirating smoke detector decreased as the fire growth speed increased and the location of the fire occurred further than the receiver of the aspirating smoke detector. Therefore, even if an aspirating smoke detector is installed in a warehouse that stores combustibles with high fire growth rates, it is judged that an additional smoke detector is attached far away from the receiver of the general smoke detector to increase fire safety.

A Fire Detection System Using Fuzzy Logic with Input Variables of Temperature and Smoke Density (열과 연기농도를 입력변수로 갖는 퍼지로직을 이용한 화재감지시스템)

  • Hong Sung-Ho;Kim Doo-Hyun;Kim Sang-Chul
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.42-51
    • /
    • 2004
  • This paper presents a study on the analysis of fire detection system using fuzzy logic with input variables of temperature and smoke density. The input variables for the fuzzy logic algorithm are measured by fire experiment of small scale with temperature detector and smoke detector. The antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire possibility. Also the triangular fuzzy membership function is chosen for input variables and fuzzy rules to simplify computation. In order to calculate fuzzy values of such fuzzy system, a computer program is developed with Matlab based on graphics user interface. The experiment was conducted with paper and ethanol to simulate flaming fire and with plastic and sawdust to model smoldering fire. The results showed that the fire detection system presented here was able to diagnose fire very precisely. With the help of algorithms using fuzzy logic we could distinguish whether fire or not.

아트리움의 Ceiling Jet 온도 예측 모델 비교

  • 김운형;김종훈;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.144-149
    • /
    • 2000
  • 최근에 국내에서도 대형 쇼핑 몰이나 건축물에 부속된 아트리움 등 대형공간을 도입한 건축물이 점차 증가하고 있다. 따라서 건물 방화 설계자는 화재시 공간의 특성에 따른 열과 연기의 확산과 이동에 관한 정량적인 해석이 필요하지만 국내에서는 아직 이에 대한 관련 규정이 미비한 실정이다. 대형 공간의 공학적인 해석은 크게 실험을 통하여 제시되는 계산공식을 이용하거나 대상 공간의 화재 조건을 예측하는 컴퓨터 모델을 이용할 수 있다. 외국의 경우, 미국의 NFPA 92B는 이러한 공간에 대한 제연 시스템에 적용하는 공식과 계산식을 제시하고 있으며 이를 통하여 연기나 열 감지기의 작동시간, 연기 발생비율, 연기 층의 하강을 제어하기 위한 배기량 등을 계산할 수 있다. (중략)

  • PDF

An Addressable Type Smoke Detect System Implementation to detect the Fire on a Ship (선박화재감지를 위한 Addressable Type Smoke Detect System 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.12
    • /
    • pp.2543-2548
    • /
    • 2011
  • The Smoke Detect System is setup to extinguish early a fire on the large ship like as the cargo ship and Bulk Carrier at sea. The Addressable Type Smoke Detect System that keeps the advantages and dispenses with the disadvantages of the existing conventional type system is composed of only one electrical cords. In this paper, we make the Smoke Detect System of an addressable type and implement to control it using ATmega Micro-controller and evaluate it.

Numerical Simulation on the Heat and Smoke Flow Phenomena Due to the Fire in a Cyclodrome (경륜장 내부의 화재발생에 따른 열 및 연기 거동에 대한 수치적 연구)

  • 박원희;김태국;손봉세
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, numerical calculations are conducted to predict the characteristics of the heat transfer and smoke propagation in a cydodrome. The gas flow velocity and temperature around the origin of the fire is obtained by using a plume model and the turbulent flow characteristics are considered by standard $textsc{k}$-$\varepsilon$ turbulent model. In this study, the transient thermal behavior can be used for designing fire detection of large rooms.

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.