• Title/Summary/Keyword: 화재저항성

Search Result 89, Processing Time 0.031 seconds

Evaluation on the Sulfate Attack Resistance of Cement Mortars with Different Exposure Conditions (노출조건에 따른 시멘트 모르타르의 황산염침식 저항성 평가)

  • Lee, Seung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.427-435
    • /
    • 2012
  • In order to evaluate the effects of exposure conditions on the resistance to sulfate attack of normal and blended cement mortars, several mechanical characteristics of the mortars such as expansion, strength and bulk density were regularly monitored for 52 cycles under sodium sulfate attack. The mortar specimens were exposed to 3 different types of exposure conditions; 1) continuous full immersion(Exposure A), continuous half-immersion(Exposure B) and cyclic wetting-drying(Exposure C). Experimental results indicated that the maximum deterioration was noted in OPC mortar specimens subjected to Exposure B, showing the wide cracks in the portions where attacking solution is adjacent to air. Additionally, the beneficial effect of ground granulated blast-furnace slag and silica fume was clearly observed showing a superior resistance against sodium sulfate attack, because of its lower permeability and densified structure. Thus, it is suggested that when concrete made with normal cement is exposed to sulfate environment, proper considerations on the exposure conditions should be taken.

Basic Study on Development of Forest Road Pavement Using Eco-Friendly Method (친환경 임도포장공법 개발을 위한 기초연구)

  • Oh, Sewook;Lee, Gilho;Kim, Donggeun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.6
    • /
    • pp.31-38
    • /
    • 2013
  • This study carried out fundamental study on the forest road pavement method of cementing the ground using the compaction equipment after laying by mixing with eco-friendly stabilizer, natural soil and water. Target strength of pavement was set to 2.0MPa and the specimen was produced per mixing ratio of cement, kinds of natural soil and curing period to evaluate the durability and unconfined compressive strength. Unconfined compressive strength test was conducted to compare strength by producing the test specimen mixing environment-friendly cement as well as the test specimen mixing cement with the same mixing ratio. To evaluate the durability, surface abrasion test and water flow resistance test were conducted. In addition, SB and GB tests were conducted using iron marble and golf ball to evaluate the walking satisfaction since it can be used by visitors due to the feature of forest road.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Analysis of Fire Intensity According to the Zones Classification in Traditional Market Stores (전통재래시장 상가간의 구역 구분에 따른 화재강도 분석)

  • Kim, Tae Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.154-160
    • /
    • 2020
  • This study analyzed the fire intensity according to the zones classification between traditional market stores using FDS software. Modeling was conducted for the Seomoon traditional market district 4 at Daegu, which places combustibles, such as textiles and clothing near the passageway. The first ignition point assumed a short circuit fire situation at the fourth store combustible. The analysis was conducted under similar conditions as the fire situation in 2016. When there was no section wall, the fire spread rapidly through radiation in all directions from the fire-origin point. After 600 seconds, the mall was burnt to the ground. When section walls were present, however, the fire could be restricted inside the compartment. The first intensity of the two analysis conditions was predicted from the total heat energy from 200 seconds (X1) to 600 seconds (X2), where the heat generation rate began to increase rapidly. As a result of installing section walls near the fire point, heat energy generation of approximately 11.12 MW (55.68 %) was delayed. Further analysis of smoke control, according to the section wall arrangement and re-installation facilities, will be needed to study the characteristics of fire in traditional markets comprehensively.

A Strength Change of the Concrete Mixed with Waste Type due to Fire (화재에 의한 폐타이어 혼합 콘크리트강도 변화에 관한 실험적 연구)

  • 손기상
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.22-26
    • /
    • 2002
  • It is very important to find out how to economically recycle waste tyres thrown away from the industry to the field. This one is also consistent with environmentally-friend policy. Many papers have been produced for focusing on the strength using waste-tyre material. Now, many kind of particle sizes of waste-tyre material are being produced in Korea, with support of the government. This study is to figure out how much the waste tyre mixing concrete resists against temperature at fire and how much decrease rate it shows. All the result are compared here in order to find out the way to applicate it to the practical structure for this area. The mixing proportion rate is selected with an experience and try-and error method. Eventually some of distinctive results are mentioned in the conclusion. The waste tyre concrete heated with $600^{\circ}C$ temperature was almost no change of its strength comparing with the normal one.

Development of a Low-Power Standalone Heat Detector Using a Critical-Temperature Switch (임계온도스위치를 이용한 저전력 단독경보형 정온식 감지기 개발)

  • Jo, Sungwoo;Jung, Sun-Kyu;Son, Jimin;Kim, Hyun-Tak
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.70-76
    • /
    • 2019
  • This paper reports development of a low-power standalone heat detector using a Critical-Temperature Switch. The Critical-Temperature Switch, which is a thermally sensitive and passive component whose resistance decreases significantly at 70 ℃ due to a metal-insulator transition, provides reliable temperature measurements. This digital-like behavior of the Critical-Temperature Switch can detect fires without a microcontroller, meaning that it can minimize the power consumption of the standalone heat detector. The experimental results showed that the standalone heat detector using the Critical-Temperature Switch complied with the Notification of the National Emergency Management Agency. Compared to conventional standalone heat detectors, only 70% of the power was consumed monitoring the fires.

A Study on fire investigation & calorie analysis of main trees in Go-sung wildfire land (고성산불지역에서의 화재조사와 주요수목의 열량분석에 관한 연구)

  • 김동현;고재선;최세환;김광일
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 1999
  • This paper contained an actual investigation of a wildfire which broke out on 23 April R 1996 in Go-sung Kun, Kang-won Do examined the calories and the total calories of the m main trees which were Quercus variabillis and Pinus densiflora. There were three important f fire spread factors which were weather condition, fuel condition and terrain. The weather c condition was the most dangerous alarm level. The fuel condition having a high calory v value, Pinus densiflora made up 63% of the forest. Terrain of the forest were mostly c covered by steep slopes and complicated line construction. This experimental calorie study a about Pinus densiflora and Quercus variabillis showed that Pinus densiflora had 13,34kcal/g a and Quercus variabillis had 9.64kcal/g. In the case of weight loss of pyrolysis, Pinus densiflora had a higher percentage rated 35.71~10.05% than Quercus variabillis. Accordingly, Pinus densiflora showed lower than Quercus variabillis in heat resistance.

  • PDF

Temperature Distribution of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance of Tunnel (터널 내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 발생시 내부온도분포)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.283-290
    • /
    • 2006
  • Concrete has advantages in fire situations as it is non-combustible and has low thermal conductivity. However, concrete that is not designed against fire can experience significant explosive spalling from the build-up of pore pressures and internal tensile stresses when heated. In this study, the performance of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system was evaluated by experimentally and numerically. The fire test was performed in fire resistance(electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von $Stra{\beta}entunneln$) time heating temperature curve, so as to evaluate the temperature distribution with cover thickness of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system. Based on experimental results and numerical analysis, the proper cover thickness of wet-mixed high strength sprayed polymer mortar determined the more than 4cm.

Enhanced Flame Resistant Properties of Aluminum Hydroxide Addition on Electrospun Polyurethane Nanofibers (전기방사법에 의해 제조된 폴리우레탄 나노섬유의 수산화알루미늄 내첨에 의한 내염화 특성 향상)

  • Kim, Hyeong Gi
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.9-13
    • /
    • 2016
  • Anti-oxidation and flame resistant polyurethane nanofibers were prepared by electrospinning and aluminum hydroxide addition. Electrospinning was carried out under the following procedure conditions; applied voltage, 20 kV; polymer solution feeding rate, 1.2 ml/h; collector rolling speed, 120 rpm; and tip to collector distance, 15 cm. Aluminum hydroxide was added to the prepared polymer solution for electrospinning to enhance the oxidation and flame resistant properties. The thermal properties were investigated by thermogravimetric analysis to determine the polymer decomposition temperature, integral procedure decomposition temperature, final decomposition temperature, and remaining amount after thermal decomposition. The activated energy for polymer degradation was also investigated using the Horowitz-Metzger equation. The activation energy increased to more than 50%. The thermal properties of the polyurethane nanofibers were improved by a hydration reaction during the thermal decomposition of aluminum hydroxide around $300{\sim}500^{\circ}C$.

Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated (인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.1-6
    • /
    • 2018
  • This study is to analyze the characteristics of the yellow insulation ring type of the CSST used for tubing when it is artificially deteriorated and damaged by burning. The CSST for tubing consists of a tube, protective coating, nut, yellow insulation ring, packing, and socket. In addition, it is thought that a yellow insulation ring and rubber packing were used to connect the tube and socket in order to improve the airtightness and insulation performance. The result of the verification of the data acquired from the tests in the 95% confidence interval shows that the Anderson-Darling (AD) and P value were analyzed to be 0.945 and 0.015, respectively. This confirms that the test data of the CSST for tubing is reliable. The analysis of the arithmetic mean of the insulation resistance of a CSST showed that the CSST damaged by burning by a torch, and the one damaged by electrical burning, was $16.7k{\Omega}$ (the greatest relatively) and $208{\Omega}$ (the lowest), respectively, while it was $1.72k{\Omega}$ in the case of a normal product. Therefore, the analysis result of the insulation resistance of the CSST collected from the scene of a fire can be utilized to examine the cause of damage by burning. In addition, it was found that when the maximum current of 97 A was applied to the CSST for about 5 s using a Primary Current Injection Test System (PCITS) the protective film and insulation ring of the CSST has no difference from that of a normal product. However, a part of the metal tube was melted.