• Title/Summary/Keyword: 화재위험성 평가

Search Result 441, Processing Time 0.028 seconds

A Study on Fire Risk Assessment of the Temple Using Fire Loads (화재하중을 통한 사찰의 화재 위험성 평가에 관한 연구)

  • Kim, Su-Young;Shin, Young-Ju;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.409-415
    • /
    • 2008
  • In this study, we considered the fire risk assessment of the temple using fire loads and the classification of combustibles. The building construction materials were classified as walls, beam-columns, floorings, ceiling panels and the loading combustibles were classified into fixed materials and movable materials. As a result, we confirmed that the total fire load of the Palsangjeon was $368\;kg/m^2$. The building construction materials accounted for approximately 93.8 percent of the total fire load and the loading combustibles accounted for approximately 6.2 percent.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Traditional Market Area (전통시장지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.46-47
    • /
    • 2017
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the traditional market area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Building Congested Area (건축물 밀집지구의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Yoon, Ung-Gi;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.226-227
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Wooden Building Congested Area (목조건물 밀집 지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Kim, Bong-Chan;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.87-88
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the wooden building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Combustion Gases in the Car Interiors (차량 내장재의 연소생성가스 분석 연구)

  • Kim, Hae-Rim;Park, Young-Ju;Lee, Seung-Chul;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.354-357
    • /
    • 2010
  • 현대 사회에서 차량은 널리 보급되어 있으며, 일상생활에서 없어서는 안 될 필수품이 되어 있다. 그러나 자동차의 증가와 함께 차량화재 및 교통사고 등과 같은 문제점들도 함께 늘고 있는 실정이다. 2009년 기준, 1년 동안의 전체 화재발생건수 47,071건 가운데 차량 화재의 발생건수가 5,958건으로 전체의 12.6% 정도를 차지하였다. 특히 차량 내장재의 주 재질은 가연성을 지닌 열가소성 합성수지들로서 화재가 발생하였을 경우, 다량의 가연성 가스 및 독성가스를 방출하기 때문에 인명 및 재산 피해를 증가시키는 문제점을 갖고 있다. 화재 시 발생하는 독성가스는 짧은 시간에 주변으로 확산되어 인명피해에 치명적인 영향을 준다. 따라서 본 연구에서는 차량에 대한 화재위험성을 다각적으로 평가하기 위해서 연소생성가스에 주안점을 두고 연구를 수행하였다. 연구결과를 살펴보면, 차량내장재의 연기밀도는 624~172, 독성지수는 13.7~2.9인 것으로 나타났다.

  • PDF

Properties Evaluation of Thermochromic Gel Compounds for Detecting Overheating (과열감지용 열변색 겔성형체의 특성 평가)

  • Kim, Jeong-Hun;Cho, Myoung-Ho;Kang, Young-Goo
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.61-66
    • /
    • 2008
  • In this research, gel compounds containing thermochromic ingredients were manufactured and evaluated to prevent the transition hazards of fire and explosion, which they are one of the methods for detecting abnormal conditions caused by overheating of special materials early. And also, compounds of viscoelastic and brushing types were manufactured as the kind and content of raw materials, and manufacturing process to enlarge the application for overheat-detecting targets. Test methods were conducted as chromism test, viscosity profile, starting time of thermochromism, and FT-IR analysis. Thermochromic gel materials exhibit chromism properties that can detect abnormal conditions effectively, and then they are possible to various applications.

Development of Comprehensive Diagnostic System for Disaster in Decline Areas (쇠퇴지역 재난재해 종합진단 시스템 프로토타입 개발)

  • Shin, Yonghyeon;Lee, Sangmin;Yang, Dongmin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.479-479
    • /
    • 2021
  • 최근 기상이변으로 인한 자연재해 발생이 증가하고 있고, 그에 따라 도시의 재난 대응력 강화가 국내에서는 물론 국제적으로도 중요한 이슈가 되고 있다. 특히 쇠퇴지역은 재난재해 발생 시 인적·물적 피해가 일반 지역 보다 상대적으로 크며, 복구에도 많은 시간과 예산이 소요되므로 대응책 마련을 위한 도시재생지역의 정밀한 재난재해의 위험성 분석 기술이 필요하다. 이에 본 연구에서는 도시재생사업 대상지(311개)에 대한 재난재해 유형별 위험성 및 회복성을 종합적으로 분석하는 종합진단 기법을 개발하고, 이를 적용한 프로토타입 시스템을 개발하였다. 재난재해의 범위는 「재난 및 안전관리 기본법」을 준용하여 이에 도시재생사업 시행에 영향을 받아 재난재해 발생에 따른 위험정도가 변화할 가능성이 높은 자연재해 (폭우, 폭염, 폭설, 강풍, 지진)5종과 사회재난 (화재, 붕괴, 폭발) 3종 총 8종으로 정의하였다. 종합진단 기법은 기후변화에 관한 정부간 협의체(IPCC) 위험도 평가 방법을 준용하여 위험요소 (위해성·취약성·노출성)와 대비·대응요소 (회복성)로 구분하고, 전문가 자문회의를 거쳐 재난재해에 특히 취약한 쇠퇴지역의 특성을 반영할 수 있는 종합진단지수 산정식을 개발하였다. 또한 쇠퇴지역 재난재해 종합진단 시스템은 도시재생 업무를 수행하는 사용자가 신속히 정보를 분석하고 활용에 용이하도록 Web-GIS 기반으로 설계하였으며, 종합진단 기법에 의해 산정된 분석결과를 100m × 100m 격자 단위의 등급으로 가시화한다. 분석 결과는 지속적인 연구 개발을 통해 최적의 도시재생사업 의사결정 지원 서비스를 위한 기초 분석 자료로 연계하여 활용되며, 분석 DB는 클라우드 서비스 기반의 도시재생 데이터 플랫폼을 통해 공유된다.

  • PDF

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.

Evaluation of Combustion Characteristics of Outdoor Advertisement Materials (옥외 광고물 소재의 연소특성 평가)

  • Eom, Sang-Yong;Kim, Kyoung-Jin;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • Combustion characteristics of outdoor advertisement materials were evaluated for fire risk assessment about fire expanding. At this study, the flame retardancy and the limiting oxygen index (LOI) was measured by UL 94 and ASTM D 2863 respectively. At the result of flame retardancy, foamex was V-0 grade and those of others were out of grade. LOI measurement showed that the LOI of foamex was highest in the samples. The cone calorimeter test was done by ISO 5660-1 to find the combustion characteristics. The cone calorimeter test showed that the outdoor advertisement materials were not good to prevent of fire expanding. The time to ignition (TTI) of flex was the fastest and the peak heat release rate (PHRR) as well as the total heat release (THR) of acrylic panel was higher than those of others.