• Title/Summary/Keyword: 화재억제

Search Result 104, Processing Time 0.022 seconds

Numerical Study on the Effects of Spray Properties of Water Mist on the Fire Suppression Mechanism (미분무수 특성이 화재억제 메커니즘에 미치는 영향에 대한 수치해석적 연구)

  • Bae, Kang-Youl;Chung, Hee-Taeg;Kim, Hyoung-Bum
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • The numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m^3$ and a water mist nozzle that be installed 1.8 m from fire pool. In the present study, the parameters of nozzle for simulation are the droplet size and the spray velocity. The droplet size influences to fire flume on fire suppression more than the spray velocity because of the effect of the terminal velocity. The optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20 m/s respectively.

A Study on the Characteristics and the Disaster Prevention Measures of Incendiary Fire (방화(放火)화재의 특성 및 방재대책에 관한 연구)

  • Choi, Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.9-21
    • /
    • 2008
  • The objective of this study is to suggest a fire prevention measure for suppressing and preventing loss of precious human lives and property damages. The characteristics of incendiary fire are analyzed in terms of fire engineering to review a plan for promoting for coping with the risk. In this study, a medical aspect such as mental and psychological analysis of the motive or act of an incendiary and legal and administrative problems such as the penalty for the incendiary are not included in the scope of the study. Fire statistics data of Korea, Japan, and U.S. are investigated for analysis of actual states of incendiary fire occurrences. In particular, to quantitatively recognize the burning characteristics of common fire and the burning characteristics of incendiary fire, a fire model test and computer simulation were performed. And a plan for promoting the optimal incendiary fire prevention measure were suggest.

철근 콘크리트 구조물의 화재조사ㆍ진단방법 및 유지관리방안(일본 콘크리리트공학협회 기준을 중심으로)

  • 권영진;이차돈;홍성걸;신영수;이경구
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.40-46
    • /
    • 2002
  • 산업화 도시화에 따른 건축물의 밀집과 고층화의 환경에서 화재 재해 발생은 인명피해 및 재산피해에 치명적인 결과를 가져올 수 있으며 화재로 인한 인명 및 재산 피해는 두말할 것도 없이 막대한 국가적 손실을 초래한다고 할 수 있다. 따라서 화재발생을 사전에 억제하는 구조물의 방화ㆍ내화구조 및 피난계획, 소화설비 소화활동설비 등에 대한 방재 연구와 더불어 화재발생후 화재의 원인조사와 구조물의 재사용 여부 또는 보강 필요성, 자산의 평가의 과학적인 근거를 위해 신뢰성 있는 안전성 평가에 대한 연구가 필요한 실정이다.(중략)

A Study on the Development of Model and Application Case of Water Screen Effect for Fire Behavior Simulation in Road Tunnel (도로터널 화재성상 시뮬레이션을 위한 워터스크린 효과 모델개발 및 적용사례)

  • Han, Jung-Chul;Kim, Se-Jong;Kim, Dong-Eun;Kurioka, Hitishi;Ootuki, Masato;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.83-88
    • /
    • 2011
  • 워터스크린(이하 W/S)에 의한 화재방화시스템은 도로터널에 화재가 발생시, 공간에 수막을 사용하여 구획화하고, 열 연기의 확산을 억제하며 유해 부유입자를 세정함으로서 인간의 안전을 확보 및 구조물의 피해를 극소화 하는 시스템이다. 이 W/S에 의한 구획의 성능을 평가하기 위해, 1/2의 터널 모형에 의한 공간 내 열 성장 파악을 위한 화재 실험을 분석하였고, 그 결과, 천정 근방 온도 및 방사수열량으로서는 발열 속도의 크기, 풍속의 대소에 의하지 않고 약 80%의 저감율을 나타냈다. 또, 발생한 유해 부유입자 농도에 대해서는 약 60%, 화원 성질과 상태로서 발열 속도는 약30%의 W/S에 의한 저감 효과를 나타내었다.

  • PDF

An Experimental Study of Fire Suppression Using a Water Mist in a Compartment (물분무를 이용한 화재제어에 관한 실험적 연구)

  • Kim, Sung-Chan;Park, Hyun-Tae;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.367-373
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. The fire extinguishing times are measured for various fire sources, fuel types, and different total flooding rates of water mist. Pool fire with hydrocabon fuel is successfully extinguished within a minute under the operating conditions of the water mist system. Two different regimes of the smoke layer cooling are observed, such as rapid and slow cooling processes. The regimes are divided by threshold time which is calculated with auto-correlation function. The threshold time for the initial cooling decreases with increasing water flow-rates and fire sources. These initial cooling effects play an important role in preventing the occurance of flashover fire by the initial fire suppression.

Simulation of a Clean Room Fire II. Needs of Smoke Control System and Springkler System (청정실 화재의 시뮬레이션 II. 제연설비와 스프링클러설비의 필요성)

  • Park, Woe-Chul;Lee, Man-Geun;Park, Hun-Sik
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.8-13
    • /
    • 2006
  • Numerical simulations were carried out for a fire in a clean room to confirm needs of a smoke control system and a sprinkler system, and to investigate a possible smoke spread-out. For a 1 MW methanol fire in a space of $39m{\times}13m$ floor and 4 m high, smoke spread-out was scrutinized for failure of the sprinkler system and/or the smoke control system. It was shown that the smoke control system removes smoke safely without the sprinkler system and that the sprinkler system is required to suppress smoke generation and spread of the fire, and to remove the smoke quickly. It was also confirmed that highly reliable sprinkler heads and automatic fire detection system are required for the sprinkler and smoke control systems.

Comparison of Korean and Foreign Standards for Cable Flame Tests (원자력 발전소 케이블의 화염 전파시험 국내외 기준 비교)

  • Lee, Dong-Min;Cho, Young-Se;Yim, Hyun-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.94-99
    • /
    • 2011
  • 원자력 발전소에 사용되는 케이블은 화재발생시 화재전파를 억제하기 위해 일정수준의 화염시험을 만족한 것을 사용하도록 규정되어 있다. 이러한 케이블 화염시험 기준은 나라마다 약간씩 차이가 있는데 본 논문에서는 국내와 미국, 프랑스, 캐나다의 원자력 발전소 케이블 화염시험 기준의 국가별 차이점을 비교 분석 하였다. 비교분석결과 각 나라의 케이블 화염시험 코드는 세부 항목별로 약간씩 차이가 있으나 전체적으로 모든 코드가 동등한 수준의 기준을 갖고 있는 것으로 분석 되었다. 따라서 어느 하나의 코드를 만족하는 전기케이블은 다른 코드의 요구 사항을 만족하는 것으로 볼 수 있다.

  • PDF

연소 생성물의 입경 분포와 소기감지기 작동에 미치는 영향

  • 하정호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.2
    • /
    • pp.81-100
    • /
    • 1983
  • 이 글은 본인이 1982년 9월부터 11월까지 약 2개월간 일본 자치성 소방연구소에서 연수중에 지도 받은 내용으로서 고층건물 등 대형건물에서 화재의 조기 감지 및 오동작억제에 많은 문제점이 대두되고 있어 동 연구소의 죽원소부씨와 도변창부씨가 공동 연구한 결과이다. 연기감지기의 작동에 영향을 미치는 연소 생성물에 대한 근본적인 연구 결과는 우리나라도 '86 Asian Game 및 '88 Olympic 등을 대비한 대형 Hotel등의 조기 화재 경보 체제를 위해 많은 도움이 될 것으로 사료되어 소개한다.

  • PDF

난연.기능성 복합성형체 제조 및 특성

  • 현병민;강영구
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.457-460
    • /
    • 2002
  • 현재 건축단열재, 흡음재, 바닥재로 사용되는 panel 성형, 제작하기 위해 다종의 유기고분자 matrix가 사용되고 있으며 polyurethane, vinyl acetate, urea-formaldehyde resin 또는 melamine-formaldehyde, phenol-form aldehyde resin 등을 사용하고 있으나 이러한 고분자 matrix를 사용한 건축용 panel의 경우 화재시 유독 gas와 더불어 급격한 화재전파의 매개체로 사용될 수 있어 난연제 첨가로 이러한 현상을 억제하고 있다.(중략)

  • PDF

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.