• Title/Summary/Keyword: 화염위치

Search Result 143, Processing Time 0.027 seconds

Smart Fire Image Recognition System using Charge-Coupled Device Camera Image (CCD 카메라 영상을 이용한 스마트 화재 영상 인식 시스템)

  • Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • This research suggested smart fire recognition system which trances firing location with CCD camera with wired/wire-less TCP/IP function and Pan/Tilt function, delivers information in real time to android system installed by smart mobile communication system and controls fire and disaster remotely. To embody suggested method, firstly, algorithm which applies hue saturation intensity (HSI) Transform for input video, eliminates surrounding lightness and unnecessary videos and segmentalized only firing videos was suggested. Secondly, Pan/Tilt function traces accurate location of firing for proper control of firing. Thirdly, android communication system installed by mobile function confirms firing state and controls it. To confirm the suggested method, 10 firing videos were input and experiment was conducted. As the result, all of 10 videos segmentalized firing sector and traced all of firing locations.

Ignition Transition by Ignition Position and Time of Gaseous Oxygen/Kerosene Combustor (기체산소/케로신 연소기에서 점화 위치 및 시간에 따른 점화 과정 연구)

  • Song, Wooseok;Shin, Dongsoo;Son, Min;Koo, Jaye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.85-90
    • /
    • 2018
  • The objective of this paper is to observe effects of ignition position and time on ignition transition. A gaseous oxygen and liquid kerosene mixture is used as propellant with a shear-coaxial injector. In order to study the ignition delay time and combustion instability intensity, the pressure transducer was used. Sequences, excepting igniter operation time, were fixed to compare the ignition time only. Initial pressure peak and ignition delay time increased as the ignition time was delayed. Additionally, an unstable flame development zone was detected when the igniter was away from the injector.

Inhibitory Effect of Chlorine Dioxide Using Reactive Oxygen Species Against Heart Contraction of the Indianmeal Moth, Plodia interpunctella (이산화염소의 활성산소 발생에 따른 화랑곡나방 심장박동 억제 효과)

  • Kim, Chul-young;Kwon, Hyeok;Kim, Wook;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.56 no.2
    • /
    • pp.147-152
    • /
    • 2017
  • Heart contraction is essential for insect hemolymph circulation, in which various physiological changes need control of the heart contraction. Thus, interruption of heartbeats intimidate insect survival. Chlorine dioxide induces release of reactive oxygen species (ROS), which has been regarded as the main insecticidal agent. This study analyzed the effect of chlorine dioxide on heartbeats of the Indianmeal moth, Plodia interpunctella. The larvae have the dorsal vessel on the medial dorsal region in a form of an extending tube from the first thorax to 10th abdominal segment. Dorsal vessel contraction was noticeable between 3rd and 10th abdominal segments, where five heart chambers were observed. Average heartbeat rate was 118.6 beats per min at $25^{\circ}C$. However, the heartbeats varied with ambient temperature. Injection of chlorine dioxide to hemocoel suppressed the heartbeats in a dose-dependent manner. The suppressive effect of chlorine dioxide also increased with exposure time to gas form of the chemical at 100 ppm. However, vitamin E (an antioxidant against ROS) treatment significantly rescued the larvae treated with chlorine dioxide in the heart contraction activity. These results suggest that chlorine dioxide negatively influences on the heart contraction of P. interpunctella via its production of ROS.

Prediction Performance of FDS on the Carbon Monoxide Production in the Under-Ventilated Fires (환기부족 화재에서 일산화탄소 발생에 대한 FDS의 예측성능)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.93-99
    • /
    • 2011
  • In the present study, a numerical simulation was conducted to estimate the prediction performance of FDS on the carbon monoxide production in the under-ventilated compartment fires. Methane and heptane fires located in the a 2/5 scale compartment based on the ISO-9705 standard room was simulated using FDS Ver. 5.5. Through the comparison between the computed results and the earlier published experimental data, the performance of FDS was estimated on the predictions of the combustion gases concentration in the hot upper layer of the compartment and the effects of CO yield rate on the estimation of CO production at local points were analyzed. From the results, it was known that FDS Ver. 5.5, in which the two-step reaction mixture fraction model implemented, was more effective on the prediction of CO concentration compared to the previous FDS version. In addition, controlling CO yield rate made the predicted CO concentration get closer to the experimental data for the fires of the under-ventilated condition.

Development of Hybrid/Dual Jet Combustor for a MGT (Part I: Experimental Study on Geometric Optimization) (마이크로 가스터빈용 하이브리드/이중 선회제트 연소기 개발 (Part I: 형상 최적화를 위한 실험연구))

  • Park, Tae-Joon;Hwang, Cheol-Hong;Lee, Kee-Man
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.60-69
    • /
    • 2013
  • An optimum configuration of the hybrid/dual swirl jet combustor for a micro-gas turbine was investigated experimentally. Location of pilot nozzle, angle and direction of swirler vane were varied systematically as main parameters under the conditions of constant thermal load. The results showed that the variation in locations of inner fuel nozzle and pilot burner resulted in significant change in flame shape and swirl intensity due to the changes in recirculating flow pattern and minimum flow area near burner exit, in particular, with the significant reduction of CO emission near lean-flammability limit. In addition, it was observed that the co-swirl configuration produced less CO and NOx emissions compared to the counter-swirl configuration.

Heat Flux Measurements in High Velocity Oxygen-Fuel Torch Flow for Testing High Thermal Materials (고온 재료 테스트를 위한 고속 산소 연료 토치 흐름에서의 열유속 측정)

  • Chinnaraj, Rajesh Kumar;Choi, Seong Man;Hong, Seong Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.2
    • /
    • pp.34-41
    • /
    • 2021
  • A commercial HVOF torch (originally designed for coating applications) has been modified as a high temperature flow source for material testing. In this study, a water cooled commercial Gardon gauge was used to measure heat fluxes at four locations away from the nozzle exit. The cooling water temperature data were used to calculate calorimetric heat fluxes at the same locations. The heat fluxes from both methods were compared and the calorimetric heat fluxes were found to be many times higher than the Gardon gauge heat fluxes. A hypothesis is applied to the calorimetric method to understand the discrepancy seen between the methods. The Gardon gauge heat fluxes are seen to be in the range of the hypothesized calorimetric calculations. This can be considered as a considerable validation for the hypothesis, but further refinement needed using appropriate numerical models.

Experimental Study on the Fire Extinguishing Characteristics of Water Mist System (미분무수 소화설비의 소화특성 실험)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Oh, Kyu-Hyung;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.78-84
    • /
    • 2009
  • We carried out fire extinguishing experiments with three kinds of water mist nozzle system. Fire extinguishing experiment according to installed nozzle height and fuel pan location was done. And fire extinguishing performance was compared with plain water and foam agent mixed solution. Water mist nozzle height was varied with 4m, 3.5m and 3m and position of fuel fan was varied 0.5m and 1m from the center of water mist nozzle. Foam agent that used in this experiment is 3% type of AFFF (Aqueous Film Forming Foam) solution. Experimental result showed the door opening effect was little. Fire extinguishing performance of foam agent mixture water mist was better than the plain water mist only.

Quadrangular Splatting based on SPH (SPH 기반의 사각 스플렛팅 가시화 기법)

  • Shin, Seung-Ho;Yoon, Jong-Chul;Lee, Jung;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.27-33
    • /
    • 2008
  • Physics-based graphic techniques are used when simulating and rendering natural phenomena such as smoke, water and flame with computational physics. We propose novel methods which render simulated particle data fast onto 3D using tetrahedron splat. We calculate the position and the normal vector of splat by SPH(smoothed particle hydrodynamics) method then we reconstruct splat into quadrangular pyramid to reduce seam. We implement this technique for SPH fluid simulation, and animate natural flow of water successfully.

  • PDF

Numerical Study on the Validity of Scaling Law for Compartment Fires (구획 화재의 상사 법칙 유효성에 관한 수치해석 연구)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2014
  • In this study, to assess the validity of scaling law which was based on the ventilation factor and utilized in fields of compartment fires, numerical simulations were conducted on full- and 2/5 reduced-scale compartment fires using FDS and simulation results were compared with the previously published experimental data. The numerical modeling used in this study was verified by comparing the predicted temperature at several points of the upper layer with the experiment data. Temperature and concentration distribution inside of compartments and velocity profile at door of compartment are analyzed to assess the validity of scaling law. Comparison between the predicted results on the full- and reduced-scale compartments shows good agreements on the inner compartment flow patterns, outflowing flame patterns from the compartments, and vertical temperature distributions.

A Study on the Design of Artificial Intelligent Exit Light (인공지능형 피난유도등 설계에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yoen;Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2200-2202
    • /
    • 2008
  • 최근 건축구조물의 복잡화, 다양화로 인하여 화재발생시 유독가스의 심각성과 공간의 특수성으로 인하여 대형 참사가 발생될 위험이 더욱 커짐에 따라 인명피해와 직접적으로 연결되는 피난탈출에 있어서 조속한 대책 마련이 시급한 실정이다. 기존 방식의 고정식 단방향을 표시하는 피난유도등은 효율적인 인명 대피 및 구조가 이루어지지 못하기 때문에 화재 발생 시 빠른 피난이 가능하도록 화재감지기와 연동하여 위험에 처한 피난자들을 탈출시키고 화재의 발생위치를 정확히 파악하여 초기 진압할 수 있는 시스템 구축이 절실히 요구된다. 이러한 점에 착안하여 ID를 가지는 화재 감지기 및 수신반과 연동하여 화재가 발생하면 화재가 발생된 방향의 반대 방향으로 모든 유도등의 방향을 제어하여 안전한 비상출입구로 사람들을 유도시키고 화염 및 연기의 방향과 속도를 계산하여 초기진압 및 최적 대피로로 방향을 표시하는 인공지능형 방향성 유도등 개발에 본 연구의 목적이 있다.

  • PDF