• Title/Summary/Keyword: 홀 측정 장비

Search Result 32, Processing Time 0.024 seconds

벤트 홀을 통한 격실 내부 압력 하강 시험 결과 분석

  • Ok, Ho-Nam;Ra, Seung-Ho;Choi, Sang-Ho;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.150-161
    • /
    • 2005
  • A test was performed to collect the data to validate an analytic method for vent hole sizing on the nose fairing of a launch vehicle. The bake-out chamber at KARI was used to simulate the ambient pressure drop, and pressure difference data were collected for a model with various kinds of vent holes which was installed in the chamber. The characteristics of the test facility and measurement equipments were evaluated for the measurement of the transient behaviors. The measured data were processed in consideration of the characteristics of the facility and equipments, and the effects of vent hole size and configuration on the pressure variation in the model were analyzed based on the data.

  • PDF

Multiple Hole Electrode를 이용한 RF CCP에서의 홀 디자인에 관한 연구

  • Lee, Heon-Su;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.437-437
    • /
    • 2010
  • DC Hollow cathode 방전은 약 100여 년 전, Paschen에 의해 실험된 이후로 광원, 스퍼터링 공정, 이온빔 소스 등 다양한 분야에 이용되어 왔다. 최근 태양전지용 마이크로 결정질 실리콘 증착 시, RF CCP의 전극에 복수의 홀 혹은 트렌치 구조를 두어 Hollow cathode 방전 효과를 이용하여 향상된 공정 속도로 공정을 진행한다. 그러나 RF-MHCD (Multi hole cathode discharge) 공정을 위한 최적 규격의 홀 기에 관한 연구는 그 중요성과 응용성에도 불구하고 깊게 이루어지지 못한 바 있다. 그러므로 저자는 Capacitively Coupled Plasma (전극 간격 : 4cm, 전극 직경 : 14cm) 장비에서 평면 전극과 10mm 깊이와 각각 3.5mm, 5mm, 7mm, 10mm 직경의 홀이 있는 4개의 전극을 이용하여 Argon RF-MHCD 방전을 관찰하여 조건 별 최적의 홀 전극 디자인을 도출하였다. 실험 조건은 64.5mTorr ~ 645mTorr압력 범위/ 1A~9A이며, 플라즈마는 전극 사이 중앙에 설치한 RF-compensated Langmuir Probe와, 전극과 전기적으로 접촉하는 1000:1 Probe 와 Voltage-Current Probe를 이용하여 측정되었다. 실험 결과 압력 조건 별로, 최적의 전자 밀도를 유도하는 전극 상 홀의 직경이 달라짐을 확인하였다.

  • PDF

A Study of In-hole Method to Measure Dynamic Stiffness of Subsurface Materials (지반의 동적물성치 측정을 위한 인홀시험법에 대한 연구)

  • Mok, Young-Jin;Jung, Jin-Hun;Kim, Young-Su;Jung, Jae-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.261-273
    • /
    • 2004
  • An in-hole seismic method has been developed to meet the requirement of economical testing cost and practicality in engineering practice to measure dynamic soil properties. The in-hole prove developed herein is small and light enough to be fit in three-inch boreholes and to be handled with bare hands. And author modified the existing equipment for the convenient purpose. In addition, the best damper suited to in-hole test was also developed. The performance of the source has been evaluated through extensive cross-hole tests and in-hole tests at various sites.

  • PDF

Development of Magnet Position Device for Outdoor Magnet Guidance Vehicle (실외 자기유도 무인운반차를 위한 자기 위치측정 장치 개발)

  • Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.259-264
    • /
    • 2014
  • This paper is research paper on the MPD(Magnet Position Device) for the outdoor MGV(Magnet /Magnet Gyro Guidance Vehicle). Usually, MGV is used in indoor environment because of a measurement height of the magnet position device. CMPD(Commercial magnet position device) has 30 mm measurement height, so this is suitable structure in indoor environment like to a flat surface. Outdoor environment is an uneven and irregular, So Outdoor MGV must has a suspension. But CMPD is unsuitable for outdoor environment because of a collision with a surface caused by suspension. Thus, measurement height of the outdoor MPD is positively necessary more than 100 mm. So, we suggest the outdoor MPD using analog magnet hall sensor, moving average filter and Characteristic(rate of the magnet hall sensor) function of the localization. Result of the experiments, the proposed Magnet Position Device for the outdoor MGV has localization accuracy 4.31 mm, measurement height 150 mm and width 150 mm and is efficient more than CMPD.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

Generation of n Precision Magnetic Filed Using Electromagnet and NMR Magnetometer (전자석과 핵자기공명 자장측정기를 이용한 정밀자장의 발생)

  • Kim, Young-Gyun;Park, Po-Gyu;Park, Jeong-Kwon
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.137-142
    • /
    • 2002
  • A precision magnetic field was generated by the NMR magnetometer and electromagnet system. The current and field feedback systems are used to control of magnetic field in the electromagnet using computer. Stability of magnetic field according to results that compare field and current feedback, current method is better than 2 times. The stability of magnetic field with current feedback improved 10 times compared with no feedback. This system is used for the calibration of magnetometers and the testing related to magnetic fields.

Development of the Mechanical Power Monitoring System for Planetary Reduction Motor using Hall Effect Sensor (홀 이펙트 센서를 이용한 유성기어 감속기모터의 동력 모니터링 시스템 개발)

  • 장인훈;오세훈;심귀보
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.201-204
    • /
    • 2004
  • 감속기가 사용되어지는 경우 부하의 변동이나 구동부의 상태변화에 따라 모터의 토크, 회전수 등이 변하는데 이러한 값들을 모니터링 하면 부하의 변동이나 구동부를 진단할 수 있다. 본 논문은 유성기어를 이용한 기어드 모터를 제작하고, LCD를 포함하는 간단한 사용자 인터페이스를 통해 전달 Torque, 전달회전수(rpm), 전달동력을 확인할 수 있는 소형의 표시기가 있는 감속기에 관한 것이다. 일반적으로 전달 토크를 측정하는 장비는 크기가 크고 고가이며 계측기를 연결하고 측정하는 과정이 매우 번거로울 뿐만 아니라 지속적인 유지보수가 필요한 단점이 있다. 본 논문에서 제안하는 유성기어를 사용하면 간단히 모터의 토크 및 회전수를 측정할 수 있고 측정값을 표시하는 표시기를 모터에 부착할 수 있다. 측정 및 표시기는 기존 가격에 비해 매우 값싸게 제작할 수 있고 유지보수가 필요 없으며 검출 값을 시스템 제어부에 피드백 시키면 자기진단이 가능해진다. 특히 블루투스를 이용한 무선 통신기능을 부과하면 원격 모니터링이 가능하고 복수 모터유닛의 네트워크 구성이 용이하며 인터넷을 통한 데이터 통신으로의 확장이 가능하다.

  • PDF

Femto-second Laser Ablation Process for Si Wafer Through-hole (펨토초 레이저 어블레이션을 이용한 Si 웨이퍼의 미세 관통 홀 가공)

  • Kim, Joo-Seok;Sim, Hyung-Sub;Lee, Seong-Hyuk;Shin, Young-Eui
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.3
    • /
    • pp.29-36
    • /
    • 2007
  • The main objectives of this study are to investigate the micro-scale energy transfer mechanism for silicon wafer and to find an efficient way for fabrication of silicon wafer through-hole by using the femtosecond pulse laser ablation. In addition, the electron-phonon interactions during laser irradiation are discussed and the carrier number density and temperatures are estimated. In particular, the present study observes the shapes of silicon wafer through-hole with $100\;{\mu}m$ diameter and it also measures the heat-affected area and the ablation depths fur different laser fluences by using the optic microscope and the three-dimensional profile measurement technique. First, from numerical investigation, it is found that the nonequilibrium state exists between electrons and phonons during laser irradiation. From experimental results, it should be noted that the heat-affected area increases with laser fluence, and the optimal conditions for through-hole formation with minimum heat affected zone are finally obtained.

  • PDF

Sputter 방식으로 형성된 다층박막 IGZO/Ag/IGZO의 IGZO증착 시간에 따른 특성 연구

  • Wang, Hong-Rae;Kim, Hong-Bae;Lee, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.290-290
    • /
    • 2012
  • 본 실험에서는 RF magnetron sputtering법과 evaporator법을 이용하여 다층박막 OMO구조를 $30{\times}30mm$ 유리기판 위에 제작하였다. Oxide층은 Sputter장비를 이용 IGZO막을 제작하였으며, Metal 층은 evaporator장비를 이용 Ag 막을 제작하였다. 변수로는 Oxide층의 시간에 따른 특성 변화를 연구하였다. 소결된 타겟으로는 In:Ga:ZnO를 각각 1:1:1 mol%의 조성비로 혼합하여 이용하였으며, Ag는 99.999%의 순도를 가진다. Oxide층의 RF sputter 공정 조건으로는 초기압력 $3.0{\times}10^{-6}$ Torr 이하로 하였으며, 증착 압력 $2.0{\times}10^{-2}$ Torr, Rf power 30 W, Ar gas 50 sccm으로 고정 시켰으며, 변수로는 5, 7, 9, 11분은 시간 차이를 두어 증착을 하였다. Metal층의 Evaporator 공정조건으로는 $5.0{\times}10^{-6}$ Torr이하, 전압은 0.3 V, Thickness moniter로 두께를 확인해가며 증착하였으며, $100{\AA}$으로 고정시켰다. 분석결과로는 XRD 측정 결과 35도 부근에서 Ag 피크가 관찰되었다. IGZO막 하나일때 90% 이상의 평균 투과율을 보였으며, 3층의 구조가 모두 증착됐을때의 투과도는 가시광영역에서 평균 80% 이상의 투과율을 보였으며, 500 nm부터 투과율이 떨어지기 시작해 800 nm부근에서는 평균 투과율이 30%까지 떨어져 Metal층인 Ag가 하나의 layer로 잘 증착이 된것을 보여주며, 플라즈몬효과를 보여줌을 알수있다. AFM측정 결과 평균 거칠기는 1.2 nm 정도의 거칠기를 확인했다. 홀 측정결과 전기적 특성은 발견되지 않았다.

  • PDF

Metal-induced Crystallization of Amorphous Semiconductor on Glass Synthesized by Combination of PIII&D and HiPIMS Process

  • Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong;Moon, Sun-Woo;Lim, Sang-Ho;Han, Seung-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.286-286
    • /
    • 2011
  • 최근 폴리머를 기판으로 하는 Flexible TFT (thin film transistor)나 3D-ULSI (three dimensional ultra large-scale integrated circuit)에서 높은 에너지 소비효율과, 빠른 반응 속도를 실현 시키기 위해 낮은 비저항(resistivity)을 가지며, 높은 홀 속도(carrier hall mobility)를 가지는 다결정 반도체 박막(poly-crystalline thin film)을 만들고자 하고 있다. 이를 실현 시키기 위해서는 높은 온도에서 장시간의 열처리가 필요하며, 이는 폴리머 기판의 문제점을 야기시킬 뿐 아니라 공정시간이 길다는 단점이 있었다. 이에 반도체 박막의 재결정화 온도를 낮춰주는 metal (Al, Ni, Co, Cu, Ag, Pd etc.,)을 이용하여 결정화 시키는 방법이 많이 연구 되어지고 있지만, 이 또한 재결정화가 이루어진 반도체 박막 안에 잔여 금속(residual metal)이 존재하게 되어 비저항을 높이고, 홀 속도를 감소시키는 단점이 있다. 이에 본 실험은 HiPIMS (High power impulse magnetron sputtering)와 PIII and D (plasma immersion ion implantation and deposition) 공정을 복합시킨 프로세스로 적은양의 금속이온주입을 통하여 재결정화 온도를 낮췄을 뿐 아니라, 잔여 하는 금속의 양도 매우 적은 다결정 반도체 박막을 만들 수 있었다. 분석 장비로는 박막의 결정화도를 측정하기 위해 GAXRD (glancing angle X-ray diffractometer)를 사용하였고, 잔여 하는 금속의 양과 화학적 결합 상태를 알아보기 위해 XPS를 통해 분석을 하였다. 마지막으로 홀 속도와 비저항을 측정하기 위해 Hall measurement와 Four-point prove를 사용하였다.

  • PDF