• Title/Summary/Keyword: 혹한기

Search Result 48, Processing Time 0.021 seconds

The Cooling Water Bypass Ratio of Packing in Plume Abatement Cooling Tower of a Combined Cycle Power Plant During Winter Operation (복합화력발전소 동계운전시 백연방지 냉각탑 냉각수의 충전재 바이패스 비율 확인)

  • Chung, Hee-Bong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.33-38
    • /
    • 2018
  • In this study, it was confirmed whether the cooling water bypass ratio of packing for plume abatement matched designed value during winter operation of combined cycle power plant. Designed operating wet bulb temperature of the plume abatement cooling tower with 29 Gcal/h capacity had a range from $13^{\circ}C$ to $-20^{\circ}C$, while its designed bypass ratio was from 0 % to 78%, so that increasing rate of the designed bypass ratio was $2.36%/^{\circ}C$ when the external temperature decreased. When the wet bulb temperature at cooling tower inlet had a range from $7.8^{\circ}C$ to $-11.8^{\circ}C$ in a normal operation, it was measured that actual bypass ratio of packing for plume abatement had a range from 23.8 % to 74.3%. While increasing rate of the actual bypass ratio was $2.71%/^{\circ}C$ in a range from $7.8^{\circ}C$ to $-9.55^{\circ}C$, it was $1.61%/^{\circ}C$ under $-10^{\circ}C$ in cold weather condition according to atmospheric temperature drop, therefore it was confirmed that the increasing rate of the bypass ratio for packing was lowered than its design.

  • PDF

Cultivational Possibilities of Camellia sinensis L. in the Mountain-area of West-Gyeongnam Province, Korea (경남 서부 산간지의 차나무 (Camellia sinensis L.) 재배 가능성)

  • Lee Seong-Tae;Shon Gil-Man;Kang Jin-ho;Lee Yong-Ho
    • Korean Journal of Plant Resources
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This study was conducted to investigate the possibility of cultivating tea plants planted in the mountain area of west Gyeongnam province, Korea for 2 years from March 27th, 2001 to July 30th 2003. Ninety each plants collected from 5 different sife were cultivated in nursery cup pot$(\phi\;16cm)$. in the greenhouse condition and transplanted in 5 different location and monitored their survival growing state etc. The results obtained are as follow : 1. Survival rate tea plants after transfer to soil was relatively high Gaya-myeon Hanyang-gun with $90.0\%$ and the lowest in Buksang-meyon Geochang-gun with $80.0\%$. The tea plant collected from Gaya-myeon showed the best growing activity at early stage. 2. For the second year of harvesting time, survival rate was the highest in Machun-myeon Hamyang-gun with $92.2\%$ and the lowest was Buksang-myeon Geochang-gun with $76.7\%$. 3. For the 3rd year of harvesting time, it was impossible to data collection because of the most upper parts of plants were killed by severe freezing weather condition. In the Baekjeon-myeon, Hamyang-gun Buksang-myeon, Ungyang-myeon Geochang-gun, which are severly cold$(below\;-10^{\circ}C)$ in winter season, seems not a suitable places for tea plant cultivation since it is very different to harvest the young loaves in growing season. In conclnsion we could select two sites Gaya-myeon, Hapcheon-gun, Machun-myeon, Hamyang-gun, as tea plant cultivation in the mountain area of west-Gyeongnam province, korea.

Study on the Temperature Distribution of Cabin under Various Car Heating Modes (난방기 출력에 따른 철도차량 객실 내부 온도 분포 분석)

  • Cho, Youngmin;Yoon, Young-Kwan;Park, Duck-Shin;Kim, Tae-Wook;Kwon, Soon-Bark;Jung, Woo-Sung;Kim, Hee-Man
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.558-565
    • /
    • 2012
  • Abnormal climate or weather is more frequently reported nowadays due to the global climate change. Especially, extremely low temperature in winter season may cause bad thermal discomfort of passengers. In this study, the effect of car heating modes on cabin temperature change and distribution was studied by using a real-scale environmental chamber for passenger cabin. It was found that the cabin temperature rose quickly at the initial stage of heating system operation, but it stopped increasing after certain point. And, temperature was higher when the height from the floor was higher. Based on the obtained result, the way to minimize the decrease of passengers' thermal comfort was suggested.

Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission (음향방출을 이용한 보일러튜브 누설평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Boiler tubes in power plants are often leaked due to various material degradations including creep and thermal fatigue damage under severe operating conditions such as high temperature and high pressure over an extended period of time. To monitor and diagnose the tubes on site and in real time, the acoustic emission (AE) technology was applied. We developed an AE leak detection system, and used it to study the variation of AE signal from the on-site tubes in response to the changes in the boiler operation condition and to detect the locations of leakage based on it. Detection of leak was performed by acquiring and evaluating the signals in separate regimes of high and low frequency signal. As a result of these studies, we found that on-line monitoring and detection of leak location for boiler tubes is possible using the developed system. Thus, the system is expected to contribute to the safe operation of power plants, and prevent economic losses due to potential leak.

In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology (음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • Valves in power plants are leaking internally by various damages including insertion of foreign objects on seat, seat crack, defects and fatigue crack of stem packing or welds etc. due to severe operating conditions such as high temperature and high pressure for extended period time. Acoustic emission(AE) technology should be applied in order to diagnose precisely and evaluate these valve internal leak. In this paper, results of studies which have accomplished in actual power plant are presented. We have analyzed background noise, AE signal level and frequency spectrum through laboratory tests on the basis of various actual conditions in power plant, and also have considered evaluation methods on the background noise, AE properties and the detectable minimum leak rate according to valve leak conditions through comparing with results of field tests in power plant. As a result of these studies, we conformed that evaluation of internal leak conditions including discrimination of leak or not, and the detectable minimum leak rate is possible, and also it is expected to contribute to safe operation and prevention of energy loss in power plants.

Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles (전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법)

  • Kim, Dae-Wan;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2545-2552
    • /
    • 2014
  • This study is aiming to suggest the effective thermal management system design technologies for the high voltage and capacity battery system of the electricity driven vehicles and introduce the theoretical designing methods. In order to investigate the effective operation of the battery system for the electricity driven vehicles, the heat generation model for Li-ion battery system using the chemical reaction while charging and discharging was suggested and the thermal loads of the heat sources (air or liquid) for cooling and heating were calculated using energy balance. Especially, the design methods for the cooling and heating of the battery system for maintaining the optimum operation temperature were investigated under heating, cooling and generated heat (during charging and discharging) conditions. The battery thermal management system for the effective battery operation of the electricity driven vehicles was suggested reasonably depending on the variation of the season and operation conditions. In addition, at the same conditions under summer season, the cooling method using the liquid and active cooling technique showed a relatively high capacity, while cooling method using the passive cooling technique showed a relatively low capacity.

Road-map for Environmental Friendly Integrated Pest Management(IPM) of Insect Pests on the Strawberry Vinyl-houses of Farmer's Field (딸기재배 하우스에서 발생하는 해충의 환경친화적 종합적방제를 위한 로드맵)

  • Lee, D.H.;Jo, C.W.;Park, C.R.;Lee, H.J.;Kang, E.J.;Seok, H.B.;Seo, M.J.;Kim, H.Y.;Kim, Y.H.;Yu, Y.M.;Youn, Y.N.
    • Korean journal of applied entomology
    • /
    • v.47 no.3
    • /
    • pp.273-286
    • /
    • 2008
  • Road-map for the environmental friendly integrated pest management(IPM) of insect pests was drawn up on the strawberry vinyl-houses of farmer's field. Major insect pests were occurred Tetranychus urticae and Aphis gossypii during the strawberry plant seeding in the vinyl house and open field. Also, same insect pests were occurred in the vinyl house during harvesting season of strawberry. For the control of T. urticae and A. gossypii, Phytoseiulus persimilis and Aphidius colemani as natural enemies were input to the vinyl house, respectively. However, because these natural enemies could not control insect pest populations, acaricide and insecticide were sprayed. Then natural enemies were input again in the vinyl house. Natural enemies could not endure the intense cold and differences of temperature and relative humidity between day and night during strawberry harvesting season. So, their behavior and control activity of pests were more decrease than pests. Firstly, natural enemies are input in the vinyl house during the early breeding season of strawberry, secondly, acaricides and insecticide are sprayed for the control of mites and aphids, respectively, during the middle breeding season in the hard winter. Finally, natural enemies are re-input in the vinyl house during the middle and late breeding season.

Effect of Mixed Pasture Using Domestic Varieties Orchardgrass 'Kodione' and Tall fescue 'Purumi' on Forage Yields and Botanical Composition in Middle Region of Korea (중부지역에서 국내육성 목초 오차드그라스 '코디원' 및 톨 페스큐 '푸르미' 이용 초지조성 혼파조합별 사초생산성 및 식생에 미치는 영향)

  • Hwang, Tae-Young;Ji, Hee Chung;Kim, Ki Yong;Lee, Sang-Hoon;Lee, Ki-Won;Choi, Gi Jun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.2
    • /
    • pp.89-97
    • /
    • 2016
  • This study was carried out to determine the effect of mixed pasture using domestic varieties orchardgrass 'Kodione' and tall fescue 'Purumi' on forage yields and botanical composition from 2013 to 2015 in middle region of Korea. The following mixed pastures were used in this study: treatment A (orchardgrass oriented mixture with imported varieties), treatment B (orchardgrass oriented mixture), treatment C (orchardgrass and tall fescue oriented mixture), treatment D (tall fescue oriented mixture), treatment E (tall fescue oriented mixture without orchardgrass), treatment F (only orchardgrass), and treatment G (only tall fescue). In botanical compositions at last cutting time in 2015, treatment A had orchardgrass at 7.1%, tall fescue at 47.9%, kentucky bluegrass at 15.2% and white clover at 25%. Meanwhile, treatment B had orchardgrass at 25.9%, tall fescue at 47.0%, kentucky bluegrass at 4.9% and white clover at 18.3%. Consequentially, in botanical composition from 2014 to 2015, treatment A was changed more compare to other treatments B, C, D and E. The average of dry matter (DM) yield for 2 years of treatment E (18,369 kg/ha) was the highest among the seven treatments, but there was no significant difference among other treatments except treatment A (p>0.05). The crude protein (CP) and in vitro dry matter digestibility (IVDMD) of treatment A were 14.5% and 74.8%, and treatment E were 14.1% and 73.0%, respectively. The content of neutral detergent fiber (NDF) and acid detergent fiber (ADF) were lower in treatment E and A than other treatments, and treatment E showed high content of total digestible nutrient (TDN). Therefore, tall fescue oriented mixture using domestic tall fescue variety Purumi had good forage productivity, quality and botanical composition in middle region of Korea for the establishment of grassland.