• Title/Summary/Keyword: 호흡 분석

Search Result 1,193, Processing Time 0.031 seconds

Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy (간암 호흡동조 방사선치료 환자의 호흡신호분석)

  • Kang, dong im;Jung, sang hoon;Kim, chul jong;Park, hee chul;Choi, byung ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Purpose : External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy Materials and Methods : May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40% ~ 60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Results : Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (${\pm}0.71sec$), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). Conclusion : This study is to analyze the acts after the breathing motion of the external markers recorded during the actual treatment was confirmed in a reproducible ratios of actual treatment of breathing motion during treatment, and Duty Cycle, planned respiratory gated window. Minimizing an error of the treatment plan using 4DCT and enhance the respiratory training and respiratory signal monitoring for effective treatment it is determined to be necessary.

  • PDF

Trends in Breath Analysis Technologies for Disease Diagnosis (질병 진단용 호흡가스 분석기술 동향)

  • Kim, Y.J.;Huh, J.D.;Kim, S.H.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.86-95
    • /
    • 2014
  • 환자의 입 냄새로 질병을 구분했다는 기록은 고대 동서양의 역사에서 많이 찾아볼 수 있다. 최근 훈련된 개가 냄새로 암환자와 정상인을 구분했다는 뉴스가 보도 되었다. 호흡가스의 분석을 이용한 질병 검진은 병원에서 진행되고 있는 기존의 고가의 장비나 혈액 채취를 이용한 방법과 비교할 때 검진자와 피검진자가 손쉽게 저가로 진행될 수 있다는 장점이 있다. 최근 인체 호흡가스 분석법에 대한 연구개발이 미국과 유럽 국가를 중심으로 활발하게 진행되고 있다. 현재는 폐암, 폐결핵, 천식 등 주로 호흡기 관련 질병에 대한 분석법이 주를 이루고 있지만, 질병과 호흡가스 성분의 연관성이 밝혀짐에 따라 호흡가스 분석에 근거한 질병 진단은 미래의 다양한 질병 진단법으로 등장할 것으로 예상된다. 본고는 최근 호흡가스 분석법으로 응용되고 있는 질량 분석법과 가스 센서 어레이 기술의 현황 및 이들의 질병 진단 응용에 대해 전망하였다.

  • PDF

Development of Respiratory Training System Using Individual Characteristic Guiding Waveform (환자고유의 호흡 패턴을 적용한 호흡 연습장치 개발 및 유용성 평가)

  • Kang, Seong-Hee;Yoon, Jai-Woong;Kim, Tae-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • The purpose of this study was to develop the respiratory training system using individual characteristic guiding waveform to reduce the impact of respiratory motion that causes artifact in radiotherapy. In order to evaluate the improvement of respiratory regularity, 5 volunteers were included and their respiratory signals were acquired using the in-house developed belt-type sensor. Respiratory training system needs 10 free breathing cycles of each volunteer to make individual characteristic guiding waveform based on Fourier series and it guides patient's next breathing. For each volunteer, free breathing and guided breathing which uses individual characteristic guiding waveform were performed to acquire the respiratory cycles for 3 min. The root mean square error (RMSE) was computed to analyze improvement of respiratory regularity in period and displacement. It was found that respiratory regularity was improved by using respiratory training system. RMSE of guided breathing decreased up to 40% in displacement and 76% in period compared with free breathing. In conclusion, since the guiding waveform was easy to follow for the volunteers, the respiratory regularity was significantly improved by using in-house developed respiratory training system. So it would be helpful to improve accuracy and efficiency during 4D-RT, 4D-CT.

Cross Correlation based Signal Classification for Monitoring System of Abnormal Respiratory Status (상관관계 기반 신호 분류를 이용한 비정상 호흡 상태 모니터링 시스템)

  • Lee, Deokwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.7-13
    • /
    • 2020
  • This paper focuses on detecting abnormal patterns of respiration of humans. In this study, a contact-based device was used to acquire both normal and abnormal respiration signals. To this end, this paper reports the development of a monitoring system to investigate the respiratory status of humans in a normal environment. This work aims to classify the respiratory status, i.e., normal and abnormal status, quantitatively. The respiration signal is acquired using a contact-based medical device (BIOBPAC), and noise reduction is carried out before classifying the respiratory status. To reduce noise, a mixed filter that combines the Savitzky-Golay filter and Median filter is applied to the acquired respiration signals. The inter-class distance is maximized, and the intra-class distance is minimized. The proposed algorithm is straightforward and can be applied to a practical environment. In addition, the experimental results are provided to substantiate the proposed approach.

Integrated Analysis System for Monitoring and Therapy of Phonation (발성 검사 및 치료를 위한 통합 장치)

  • 남기창;김수찬;김한수;남지인;남도현;김덕원;최홍식
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2883-2886
    • /
    • 2003
  • 좋은 발성을 위하여 음성이 만들어지려면, 뇌의 언어중추의 명령에 의하여 신경망을 통하여 ‘호흡기관(폐와 흉곽. 호흡관련 근육들)’과 ‘발성기관(주로 후두 즉 성대)’ 그리고 ‘조음, 공명기관(인두, 구강 및 비강)’의 근육들이 유기적으로 작용하여야 한다. 이런 협력 체제에 문제가 생기면, 다양한 종류의 질환이 유발될 수 있다[1,2]. 현재 임상에서 음성 분석을 위해 사용되는 시스템은 대부분 성대의 진동을 측정하기 위해 stroboscopy, 전기성문파형검법 (EGG, electroglottography), 후두근전도 중의 한 방법과 음성 분석을 위한 분석 프로그램으로 구성되어 있다. 그러나, 발성은 호흡과 매우 밀접한 관계가 있어 음성, 성대의 진동, 호흡 관계를 종합적으로 관찰할 필요가 있다. 본 연구에서는 발성 시 성대 점막의 접촉 양상은 ECG 로 측정하며, 발성의 주 에너지원이 되는 호흡의 변화를 2 channel 인덕턴스 호흡감시 장치(RIP: repiratory inductive plethymography)를 이용하여 흉곽의 움직임과 상 복강의 움직임에 대하여 측정하며, 발성되는 음성은 마이크로폰을 통하여 측정하는 ‘EGG, 음성, 호흡 통합검사 장치’를 개발하였다.

  • PDF

Prevalence and Predictors of Nocturia in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성수면무호흡증 환자의 야간뇨 유병률 및 관련인자)

  • Kang, Hyeon Hui;Lee, Jongmin;Lee, Sang Haak;Moon, Hwa Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.1
    • /
    • pp.14-20
    • /
    • 2014
  • Objectives: Several studies suggest that nocturia may be related to obstructive sleep apnea syndrome (OSAS). The mechanism by which OSAS develops nocturia has not been determined. The present study aimed to determine the prevalence of nocturia among adults with OSAS and to identify factors that may be predictive in this regard. Methods: Retrospective review of clinical and polysomnographic data obtained from patients evaluated at the sleep clinics of the St. Paul's Hospital between 2009 and 2012. The urinary symptoms were assessed on the basis of the International Prostate Symptom Score (IPSS). Pathologic nocturia was defined as two or more urination events per night. OSAS was defined as apnea-hypopnea index (AHI) ${\geq}5$. A multivariate analysis using logistic regression was performed to examine the relationship between polysomnographic variables and the presence of pathologic nocturia, while controlling for confounding factor. Results: A total of 161 men >18 years of age (mean age $46.7{\pm}14.1$), who had been referred to a sleep laboratory, were included in the present study. Among these, 27 patients with primary snoring and 134 patients with obstructive sleep apnea were confirmed by polysomnography. Nocturia was found in 53 patients with OSAS (39.6%) and 8 patients with primary snoring (29.6%). The AHI was higher in patients with nocturia than in those without nocturia (p=0.001). OSAS patients with nocturia had higher arousal index (p=0.044), and lower nadir oxyhemoglobin saturation (p=0.001). Multiple regression analysis showed that age (${\beta}$=0.227, p=0.003), and AHI (${\beta}$=0.258, p=0.001) were associated with nocturia, and that the presence of pathologic nocturia was predicted by age (OR 1.04 ; p=0.004) and AHI (OR 1.02 ; p=0.001). Conclusion: Nocturia is common among patients with OSAS. The strongest predictors of nocturia are age and AHI in patients with OSAS.

Statistical Study on Respiratory Signal Analysis according to Patient Position and Device in Radiation Therapy (방사선치료 시 자세와 device에 따른 호흡신호의 분석)

  • Seo, Jeong-Min;Park, Myung-Hwan;Shim, Jae-Koo;Kim, Chan-Hyeong;Park, Cheol-Soo;Kim, Kyung-Keun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 2011
  • This study statistically analyzed the difference of the stability of maintaining a respiratory period shown according to position and use of a device to search the tendency and usefulness of a device. The supine position showed better maintaining respiratory cycles than the prone position. The 85% of subjects who showed bad maintenance pattern of a respiratory cycle were significantly different pattern with using belly board. It could be said that there was a significant correlation between the maintenance of a respiratory cycle and relative index of respirational stability(p=0.044, kappa=0.607). The movement due to respiration was one of important considerations in the radiation therapy on chest, abdomen, and even pelvis. This study could contribute to the high quality radiation therapy by statistic analysis of respiratory signals and its application.

Differences of EEG and Sleep Structure in Pediatric Sleep Apnea and Controls (소아 수면무호흡증 환아와 정상 소아에서 수면구조와 뇌파 양상 차이)

  • Ahn, Young-Min;Shin, Hong-Beom;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.71-76
    • /
    • 2008
  • Introduction: In this study, we compared sleep structure, EEG characteristic of pediatric obstructive sleep apnea (OSA) and normal controls which were matched in sex and age. Methods: Fifteen children (male:female=4:11) who complained snoring and were suspected to have sleep apnea and their age and sex matched normal controls (male:female=5:10) have been done nocturnal polysomnography (NPSG). Sleep parameters, sleep apnea variables and relative spectral components of EEG from NPSG have been compared between both groups. Results: Pediatric OSA group were distinguished from normal controls in terms of apnea index, respiratory disturbance index and nadir of oxyhemoglobulin desaturation. Pediatric OSA group showed increased percent of sleep stage 1, decreased rapid eye movement sleep percent and increased delta power in O1 EEG channel. However other sleep parameters and spectral powers were not different between two groups. Conclusion: In pediatric OSA group, sleep structure parameter disruption may be not prominent as the previous studies for adult OSA group because of including mild OSA data in diagnostic criteria. In addition, EEG changes might not be distinct due to low arousal index compared to adult OSA patients. We can observe general characteristics and particularity of pediatric OSA through this study.

  • PDF

Evaluation of Dose Distributions calculated with ITV Measurement Plan Data and PTV Measurement plan Data under the condition of Respiratory Motion during 3D for ABD Cancer (내부표적체적 기반의 치료계획과 호흡연동 기법을 적용한 치료계획과의 선량비교 분석)

  • Park, Ho-Chun;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.227-228
    • /
    • 2014
  • 방사선치료의 발전으로 3차원치료보다 진보된 호흡연동방사선치료가 시행되어지고 있다. 호흡의 규칙성과 환자의 위치 재현성이 중요한 치료적응 인자이며, 호흡연동 방사선치료의 효율을 높일 수 있는 지표이다. 국가암통계상 고령의 암환자가 증가하며, 수술, 화학요법을 병행하는 암 치료법이 널리 이용이 되고 있다. 고식적인 치료를 요하는 고령의 복부 암 환자분들에 호흡연동 방사선치료법을 사용하는데 에는 호흡의 불규칙성과 체위의 재현성의 문제점으로 인한 치료 효율의 저하를 가져온다. 본 연구에서는 호흡에 의한 종양 움직임이 있는 방사선 치료에서 내부표적체적 기반의 치료계획과 호흡연동 기법을 적용한 치료계획과의 선량비교 분석하였다. 2가지 치료법 모두 정상조직 보호선량에 부합한 것으로 나타났으며 치료체적은 처방선량의 95%이상 포함된 선량분포로 적합하였다. ITV 설정을 통한 3D Plan은 고식적 치료을 목적으로 하는 고령의 환자, 체위 및 호흡의 불안정성 환자에게 처방선량의 95% 이상의 4D Plan의 치료법 보다 짧은 시간에 치료함으로써 치료효율을 높일 수 있을 거라 사료된다. 다만 정상조직보호선량(NTCP)에 부합하는지에 대한 평가가 전제되어야 한다.

  • PDF

A Study on Utilization Improvement of Resuscitation Equipment on Board Ships (선박 내 구조호흡 장비 활용 개선에 관한 연구)

  • Jeong-Hee Hwang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.819-827
    • /
    • 2023
  • If respiratory arrest occurs or cardiopulmonary resuscitation (CPR) is performed for a long period on board ships, CPR with rescue breathing (not compression-only CPR) is required. Accordingly, ships must have resuscitation equipment for oxygen supply, and seafarers must have the maritime competence to use it. This study aimed to analyze the placement status of resuscitation equipment on ships and seafarers' intention to use them in order to increase the usability of resuscitation equipment on board ships and propose improvement measures. The study was conducted from February 2, 2023, to April 21, 2023, and a total of 340 seafarers were surveyed. The data were analyzed by frequency, percentage, and chi-square test using SPSS WIN 23.0. The results showed that the checking of resuscitation equipment was high among seafarers in the positions of officer, captain, deck department personnel, and ocean-going personnel. The intention of seafarers to use resuscitation equipment was low, and the main barrier was the lack of knowledge on how to use. Among the general characteristics of the study participants, those whose rank was that of officer or captain, whose working department was the deck, voyage who were ocean-going, and who managed a gross tonnage of 20,000 tons or more had a high intention to use resuscitation equipment. Participants who knew the necessity of rescue breathing and had received practice and equipment-based training were active in using resuscitation equipment. Therefore, a system should be developed so that all ships can be equipped with resuscitation equipment, and an environment must be created to increase accessibility to resuscitation equipment on board ships. In addition, an education system based on practical and resuscitation equipment training must be established to ensure that seafarers have maritime competence.