• Title/Summary/Keyword: 호흡량측정기

Search Result 21, Processing Time 0.04 seconds

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF

A Review on Soil Respiration Measurement and Its Application in Korea (토양호흡의 측정과 국내 연구 현황에 대한 고찰)

  • Lee, Eun-Hye;Lim, Jong-Hwan;Lee, Jae-Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.264-276
    • /
    • 2010
  • The objectives of this study were to introduce the methods of soil respiration measurement, to review soil respiration studies conducted in Korea, and to suggest potential issues generated from using various methods for soil respiration measurement. According to the measurement principles, the methods of soil respiration measurements are classified as: alkali absorption method (AA), closed chamber method (CC), closed dynamic chamber method (CDC), and open flow method (OF). Based on the litereaure review on soil respiration studies in Korea, the CDC method was mostly used by the researchers (62%), followed by the AA (17%), OF (13%) and CC (8%) methods. Along with these methods, various instruments were used such as LI-6400-09, EGM-3, EGM-4, and automatic soil respiration chamber. Most of the soil respiration measurements were carried out in forest ecosystems and the reported soil respiration showed a wide range of variations from 130 to 900 mg $CO_2\;m^{-2}h^{-1}$. Continuous monitoring of soil respiration with minimal disturbance and the potential inconsistency in measurements are still the challenges facing the researchers, causing a paucity in quality datasets of sufficient quantity. Few attempts of intercomparison among different methods hinder the data users from synthetic analysis and assessment of the collected datasets. In order to better estimate soil carbon budget and understand their exchange mechanisms in key ecosystems of Korea, it is necessary to measure soil respiration at various plant functional types, soils, and climate conditions over a decadal time scale along with the study on the partitioning of soil respiration into autotrophic and heteorotrophic components.

A Study on the Effects of the Breath Efficiency & Lung Capacity Improvement Using Recorder Playing Focused on Breath Training (리코더 연주를 통한 뇌졸중 노력성 폐활량과 호흡 효율성 향상 연구)

  • Choi, Sung Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.1
    • /
    • pp.31-46
    • /
    • 2007
  • The purpose of the study was to improve the efficiency of Breath & Forced Vital Capacity(FVC) of Stroke Patients Using Record Playing Focused on Breath Training. The Training of Forced Vital Capacity(FVC) is focused on trunk muscles reinforce for Breathing. So the study tried to play Recorder for reinforcing FVC. The play included the two parts. One was for solo play, the other was play in concert base on solo play using Korea country song, Arirang. The Recorder play used abdominal breath, Pursed-lip & Paced methods. The course of play included Long Tone, Staccato, Crescendo, Decrescendo and throughout the course we tried to improve the efficiency & Quantity of breathe. Experiment performed at Social welfare institute for the old. They played & checked FVC, $FEV_1$, $FEV_1/FVC$ before & after breathe 19 times for 6 weeks using Spirovit SP-1, Schiller. After experiment we performed statical process(p<0.05) using statical Package software. The findings were as follows: Analysis for Experiment showed the numerical Value of increasing Of FVC, $FEV_1$, $FEV_1/FVC$. Increasing Percentage of Measured/Predicted FVC, $FEV_1$ (or calculated based on theory) ration was 25%, 13% and Quantity of FVC, $FEV_1$ 35%, 40%. Also $FEV_1/FVC$ Ratio(showed efficiency of breathe) raised 13%. And experiment data was confirmed by statical process. The experiment data was valuable under p<0.05. In Conclusion we think the results of experiment showed the efficiency of Music therapy for Breathe(FVC, $FEV_1$, $FEV_1/FVC$) reinforce.

  • PDF

The Effect of Rain Fall Event on $CO_2$ Emission in Pinus koraiensis Plantation in Mt. Taehwa (강우 이벤트가 태화산 잣나무 식재림의 각 발생원별 $CO_2$ 발생량에 미치는 영향)

  • Suh, Sanguk;Park, Sungae;Shim, Kyuyoung;Yang, Byeonggug;Choi, Eunjung;Lee, Jaeseok;Kim, Taekyu
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.4
    • /
    • pp.389-394
    • /
    • 2014
  • This study was conducted to find out the soil $CO_2$ emission characteristic due to rain fall pattern and intensity changes. Using Automatic Opening and Closing Chambers (AOCCs), we have measured annual soil respiration changes in Pinus koraiensis plantation at Seoul National University experimental forest in Mt. Taehwa. In addition, we have monitored heterotrophic respiration at trenching sites ($4{\times}6m$). Based on the one year data of soil respiration and heterotrophic respiration, we observed that 24% of soil respiration was derived from root respiration. During the rainy season (end of July to September), soil respiration at trenching site and trenching with rainfall interception site were measure during portable soil respiration analyzer (GMP343, Vaisala, Helsinki, Finland). Surprisingly, even after days of continuous heavy rain, soil water content did not exceed 20%. Based on this observation, we suggest that the maximum water holding capacity is about 20%, and relatively lower soil water contents during the dry season affect the vital degree of trees and soil microbe. As for soil respiration under different rain intensity, it was increased about 14.4% under 10 mm precipitation. But the high-intensity rain condition, such as more than 10 mm precipitation, caused the decrease of soil respiration up to 25.5%. Taken together, this study suggests that the pattern of soil respiration can be regulated by not only soil temperature but also due to the rain fall intensity.

호흡율 측정기를 이용한 폐수처리 공정수의 생물학적 활성측정

  • Lee, Yeong-Rak;Lee, Gi-Yong;Im, Ji-Hun;Lee, Sang-Hun;Mun, Hong-Man;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.463-466
    • /
    • 2000
  • In this study, it was observed to oxygen uptake rate(OUR) on microbes in activated sludge process. OUR was showed to 43, 55, and $64\;mgO_2/L/hr$ when inoculated microbes mass were 3, 5, and 10%(v/v%). In additon to oxygen was consumed to $4{\sim}42\;mgO_2/L/hr$ as changed substrate concentration. Also, we were measured kinetics coefficient in order to know growth tendency. It was concluded to maximum growth rate$(\;{\mu}\;_{max})$, $2.7\;day^{-1}$, yield coefficient, 0.655, and half-velocity coefficient, 36.11 mg/L.

  • PDF

Optimal DO Setpoint Decision and Electric Cost Saving in Aerobic Reactor Using Respirometer and Air Blower Control (호흡률 및 송풍기 제어 기반 포기조 최적 DO 농도 설정과 전력 비용 절감 연구)

  • Lee, Kwang Su;Kim, Minhan;Kim, Jongrack;Yoo, Changkyoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.581-586
    • /
    • 2014
  • Main objects for wastewater treatment operation are to maintain effluent water quality and minimize operation cost. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. The oxygen uptake rate (OUR) is real-time measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO set-point needed for the micro-organism is suggested based on real-time measurement of oxygen uptake of micro-organism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal set-point decision system by providing the necessary oxygen supply requirement to the micro-organisms coping with the variations of influent loading.

The effects of lumbar stabilization exercise on respiratory pressure in stroke patients (허리안정화운동이 뇌졸중환자의 호흡압력에 미치는 영향)

  • Park, Shin-Jun;Oh, Dae-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.357-364
    • /
    • 2017
  • The purpose of this study was to investigate the exercise periods changes of the waist stabilization exercise on the inspiratory and expiratory pressure of stroke patients. Thirty-six stroke patients were divided into 17 lumbar stabilization group(LSEG) and 19 general exercise group(GPEG). In both groups, inspiratory and expiratory pressure using a respiratory pressure device was measured over 4 and 8 weeks. At maximal expiratory pressure, LSEG was significantly increased in Before, 4 weeks and 8 weeks according to the period, but there was no significant difference in GPEG in all periods. At maximal inspiratory presusre, there was no significant difference in LSEG between before-4 weeks and 4-8 weeks, but there was a significant increase in Before-8weeks. There was no significant difference in all periods of GPEG group. There was no significant difference in the amount of change between the two groups. In this study, it was found that the lumbar stabilization exercise was effective in improving the expiratory pressure in the stroke patients. If the stroke patient continues to lumbar stabilization exercise, it is also an effective method for inspiratory pressure. Future studies are expected to study individual respiratory muscle measurements after lumbar stabilization exercise.

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Investigation of the fate of inorganic nitrogens in the near field of bank filtration site (강둑여과지 주변의 밭에 살포된 무기질소의 거동 연구)

  • 공인철;배진희;안호준;권오억;김승현;이철희;박영규
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.11-20
    • /
    • 1998
  • Inorganic nitrogens resulting from fertilizers are possible contaminants of bank-filtered ground water, which is an alternative source of safe drinking water. We conducted a laboratory study to determine the fate of inorganic nitrogens in the near field of bank filtration sites and we consequently illustrated the effects of these possible contaminants on the water quailty of bank filtration. Soil properties were found to be well equivalent to those of other cultivated field soils in Korea. Surface soil pH was about 4.3 which is slightly lower than average level. Overall, diverse concentrations of $NO_3$-N and $NH_3$-N were measured, and $NO_2$-N was nearly undetected. $NH_3$-N level in the field decreased, while $NO_3$-N increased along with increasing depth of unsaturated zone. Numbers of viable and nitrifying bacteria ranged from 6.73$\times$$10^{6}$to 10.7$\times$$10^{6}$ and 0.44$\times$$10^{4}$ to 5.21$\times$$10^{4}$ respectively, and both of them were highly correlated ($R^{2}$=0.992). Nitrifying potential assayed by batch test showed relatively lower than other reported results. The oxygen uptake potential of surface and subsurface soil was measured in the presence of ${(NH_4)_2}$$SO_4$. The results demonstrated that surface soil required shorter lag period and uptaked more oxygen than subsurface's.

  • PDF

Design and Implementation of Biological Signal Measurement Algorithm for Remote Patient Monitoring based on IoT (IoT기반 원격환자모니터링을 위한 생체신호 측정 알고리즘 설계 및 구현)

  • Jung, Ae-Ran;You, Yong-Min;Lee, Sang-Joon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.6
    • /
    • pp.957-966
    • /
    • 2018
  • Recently, the demand for remote patient monitoring based on IoT has been increased due to aging population and an increase in single-person household. A non-contact biological signal measurement system using multiple IR-UWB radars for remote patient monitoring is proposed in this paper. To reduce error signals, a multilayer Subtraction algorithm is applied because when the background subtraction algorithm was applied to the biological signal processing, errors occurred such as voltage noise and staircase phenomenon. Therefore, a multilayer background subtraction algorithm is applied to reduce error occurrence. The multilayer background subtraction algorithm extracts the signal by calculating the amount of change between the previous clutter and the current clutter. In this study, the SVD algorithm is used. We applied the improved multilayer background subtraction algorithm to biological signal measurement and computed the respiration rate through Fast Fourier Transform (FFT). To verify the proposed system using IR-UWB radars and multilayer background subtraction algorithm, the respiration rate was measured. The validity of this study was verified by obtaining a precision of 97.36% as a result of a control experiment with Neulog's attachment type breathing apparatus. The implemented algorithm improves the inconvenience of the existing contact wearable method.