• Title/Summary/Keyword: 형광 X-선

Search Result 212, Processing Time 0.028 seconds

Discrimination of Geographic Origin by Trace Elements Contents in Rehmannia Radix Preparat using X-ray Fluorescence Analysis (X-선 형광 분석방법을 이용한 숙지황의 무기원소 함량분석과 지리적 특성 규명)

  • Bae, Hey-Ree;Lee, Si-Kyung;Whang, In-Jae;Kang, Jeong-Mi;Lee, Jin-Ho;Kim, Jeong-Han
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.4
    • /
    • pp.345-348
    • /
    • 2015
  • Dried Rehmannia Radix Preparat, produced in different geographic origins of Korea and China, were investigated for the trace element contents using X-ray fluorescence spectrometry. When the estimated data for 35 kind of elements including K, P, S, Cl, Si, Al, Fe, Sn, etc on 143 samples were analyzed by canonical discrimination technique, the average classification correct rate was 92.3% and the significance was less than 0.0001. In case of reducing the number of elements for statistic analysis from 35 to 8 and to 3, the correct rates were also reduced to 88.1% and to 84.6%. The correct rate for Chinese samples ranged from 94.6-96.0%, while those for Korean ranged from 72.5-89.9%.

Synthesis and luminescent properties of $Er^{3+}$ doped $CaZrO_3$ long persistent phosphors ($Er^{3+}$를 첨가한 $CaZrO_3$ 축광성 형광체의 합성 및 발광 특성 분석)

  • Park, Byeong-Seok;Choi, Jong-Koen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Novel long persistent phosphors of $CaZrO_3:Er^{3+}$ have been synthesized by traditional solid state reaction method. The long persistent phosphor crystalline particles were characterized by the X-ray diffraction (XRD), photoluminescence spectrophotometer, thermoluminescence (TL) and luminance meter. The results reveal that the samples are composed of single $CaZrO_3$ phase. The broadband emission spectra of 446 nm peak and 550 nm peak was revealed by synthesized at high temperature in $N_2$ gas. Green long persistent phosphors have been observed in the sys_em for over 6 h after UV irradiation (254 nm). The main emission peak was ascribed to $Er^{3+}$ ions transition from $^5D_{5/2}{\rightarrow}^4F_{9/2},\;^2H_{12/2},\;^4S_{3/2}{\rightarrow}^4I_{13/2}\;and\;^2G_{9/2}{\rightarrow}^4I_{13/2}$, and the afterglow may be ascribed to the suitable trap centers in the $CaZrO_3$ host lattice.

Development of Monoenergetic Photon Source in the Energe Range below 100 keV by the X-ray Fluorescence Method (형광 X 선을 이용한 100 KeV 이하의 에너지 영역에서의 단색 Photon 선원개발에 관한 연구)

  • Lee, Youn-Myoung;Lee, Kun-Jai;Hah, Suck-Ho;Hwang, Sun-Tae;Lee, Kyung-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.14-28
    • /
    • 1985
  • The development of mono energetic photon sources using $K_{\alpha}$ fluorescence X-ray of pure material was carried out in the energy range below 100 keV. The monoenergetic photons are very useful in the calibration of the radiation measuring instruments and can be produced as the $K_{\alpha}$ fluorescence X-ray by irradiating the bremsstrahlung to the thin pure metal foils called ‘radiators’. In this experiment, several radiators such as $_{47}Ag,\;_{50}Sn,\;_{68}Er,\;_{70}Yb,\;and\;_{82}Pb$ provide the wide monoenergetic photon energy ranging from 20 keV to 80 keV. By the spectrometry with HpGe LEPS, spectral purity factors which measure the monochrometicity for the $K_{\alpha}$ fluorescence X-ray, were determined as $0.64{\sim}0.94$. Dosimetry for the purpose of the determination of the exposure rate with a 600cc thin window ionization chamber, which was calibrated by the standard free-air ionization chamber, was performed. Exposure rates ranging $8.3{\sim}232.5mR/h$ was obtained according to the $K_{\alpha}$ fluorescence X-ray energy for each radiator.

  • PDF

Implementation of Efficient Pile-up Pulse Processing Algorithm Based on Trapezoidal Filter (사다리꼴 필터를 이용한 효율적인 중첩펄스 처리 알고리즘 구현)

  • Piao, Zheyan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.162-167
    • /
    • 2013
  • X-ray or ${\gamma}$-ray spectroscopy systems are widely used for analyzing material characteristics. Pile-up pulses are very often encountered for several reasons in XRF systems. Thus, it is necessary to reject or recover pile-up pulses to accurately analyze the material under test. In this paper, a pile up pulse rejection and recovery method is presented for XRF systems using trapezoidal pulse shaping of the input signals. Since the proposed method is based on the trapezoidal pulse shaping method widely-used in XRF systems, only two counters and a few registers are needed to implement the additional function of pile-up pulse rejection and recovery. Consequently, the proposed system is much simpler than conventional pulse reconstruction systems. It is shown that the proposed method can detect and reject pile-up pulses exactly. It is also shown that the pile-up pulses can be recovered if some conditions are satisfied.

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

Construction of fluorescent red silk using fibroin H-chain expression system (누에 형질전환에 의한 견사선에서의 적색형광단백질 발현)

  • Kim, Sung Wan;Yun, Eun Young;Choi, Kwang-Ho;Kim, Seong Ryul;Park, Seung Won;Kang, Seok Woo;Kwon, O-Yu;Goo, Tae Won
    • Journal of Sericultural and Entomological Science
    • /
    • v.50 no.2
    • /
    • pp.87-92
    • /
    • 2012
  • We constructed the fibroin H-chain expression system to produce Discosoma sp. red fluorescent protein variant2 (DsRed2) in transgenic silkworm cocoon. Fluorescent cocoon could be made by fusing DsRed2 cDNA to the heavy chain gene and injecting it into a silkworm. The DsRed2 fusion protein, each with N- and C-terminal sequences of the fibroin H-chain, was designed to be secreted into the lumen of the posterior silk glands. The expression of the DsRed2/H-chain fusion gene was regulated by the fibroin H-chain promoter. The use of the 3xP3-driven EGFP cDNA as a marker allowed us to rapidly distinguish transgenic silkworms. The EGFP fluorescence became visible in the ocelli and in the central and peripheral nervous system on the seventh day of embryonic development. A mixture of the donor and helper vector was micro-injected into 1,020 Kumokjam, bivoltin silkworm eggs. We obtained 6 broods. The cocoon was displayed strong red fluorescence, proving that the fusion protein was present in the cocoon. Accordingly, we suggest that the DsRed2 fluorescence silk will enable the production of novel biomaterial based on the transgenic silk.

Cyanine 및 Merocyanine색소의 분광특성 및 광전특성(2)

  • 손세모;권태선;김성훈
    • Proceedings of the Korean Printing Society Conference
    • /
    • 1995.11a
    • /
    • pp.13-17
    • /
    • 1995
  • 헤테로원자(X=O, S, Se)의 변환에 따라 용액상에서 Merocyanine색소 및 Cyanine색소의 헤테로원자X는 p궤도의 원자보다 d궤도의 원자가 공명에 관여하여 공역계확장에 기여하였고, 유전률이 큰 용매 일수륵 Merocyanine색소는 장파장으로 흡수극대치가 이동하였다. 또 Cyanine색소의 기저상태는 $I^-$이온과 정전하 발색단을 가진 이온성 화합물로 되어 있으므로 극성용매에서 $I^-$ 이온의 전하가 색소본체로 전하 이동전이가 발생하여 단파장화 하였다. 고상에서 색소의 농도가 높을 수록 색소분자간의 거리가 가까워져 색소 상호작용이 변화하여 흡수스펙트럼에서는 전체적으로 폭이 넓은 형태로 나타났으며 이것은 농도가 높을 수록 색소분자간의 거리가 가까워져 색소 상호작용이 변화한 때문이라고 생각된다. 또한 3차원 형광의 저농도에서 보이지 않는 새로운 스펙트럼이 Cyanine색소에서 나타났으며 이 스펙트럼은 색소고유의 흡수에 기인한 것으로 Eximer형광으로 생각된다. 광전특성에 있어서는 Merocyanine색소가 Cyanine색소보다 활성화에너지가 낮아 전하이동도가 커짐에 따라 높은 광전특성을 나타내었다. 그리고 Merocyanine색소 헤테로원자(X)의 비교에서 광전특성은 O

  • PDF

디스플레이용 PDP의 X-ray에 대한 반응특성 평가

  • Yun, Min-Seok;Jo, Seong-Ho;Gang, Sang-Sik;Cha, Byeong-Yeol;Kim, So-Yeong;Son, Dae-Ung;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.531-531
    • /
    • 2007
  • 현재 널리 사용되고 있는 X선 영상 검출기의 문제점을 해결하기 위해 새로운 연구가 활발히 진행되고 있다. 본 논문에서는 새로운 X선 검출기로써의 가능성 제시를 위해 Display용 PDP(Plasma Display panel)를 디지털 X-ray Detector로 적용하기 위한 기본적인 X-ray에 대한 반응성을 검증하였다. PDP의 X-ray Detector로의 사용 가능성을 보기 위하여, 실험에 사용된 panel은 상용화된(commercial) Display용 PDP의 기본적인 구조와 똑같은 구조의 sample을 제작하여 사용하였다. 제작된 panel은 상판에 Substrate glass와 유전체층, 투명전극을 형성하고, 버스 전극층과 MgO층을 형성하였다. 하판에는 격벽을 제작하고 형광체(R.G.B)층을 형성하고, 어드레스 전극을 형성하여 기존의 Display용 PDP와 똑같은 구조를 지니게 하였다. 이렇게 제작된 panel의 X-선 검출기로서의 전기적 특성물 조사하기 위해 누설전류(Dark current), X선 민감도(X-ray sensitivity), 그리고 선형특성(Linearity)을 측정하였다. 측정 결과, 누설전류가 낮고 X-선 검출기로서의 가능성이 충분한 민감도를 보이며, 선형적 특성 또한 우수한 결과를 보이는 등 안정된 전기적 동작특성을 보였다. 이러한 결과로부터 기존에 사용되어오던 디스플레이용 PDP의 구조적 변경을 통하여 상용화된 PDP룰 디지털 X-선 검출기로서의 적용 가능성을 확인할 수 있었다.

  • PDF

Fire Performance Testing Method for Fire Retardant EPS Sandwich Panel Using X-ray Analysis (X-선 분석법을 이용한 난연 EPS 샌드위치 패널의 화재성능평가 방법에 관한 연구)

  • Shim, Ji-Hun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.76-83
    • /
    • 2015
  • EPS sandwich panel contains flame retardants that slow down ignition during fires,reduce the amount of heat generated, and block the spread of combustion. However, if a sandwich panel does not satisfy standards for fire-retardant performance, it may increase damage to property and human life. It is difficult to test the fire-retardant performance of a finishing material with the naked eye, so it is necessary to develop convenient and fast evaluation methods that are convenient and fast. In this study, a fire safety evaluation method for EPS sandwich panel was analyzed using X-ray to detect specific components related to the fire-retardant performance X-ray fluorescence analysis (XRF) indicated that suitable panel products contained more aluminum in comparison to unsuitable products. Gibbsite was identified as the main crystalline material of flame retardant EPS through X-ray diffraction analysis (XRD) and was included in both suitable products and unsuitable products, but there was a difference in crystalline structure. This study was verifies the possibility of evaluating fire-retardant performance using ultimate analysis and crystal analysis through these X-ray methods.

Analyses of Mineral Composition of Geochang Granitic Rocks for Stone Specification (거창화강석 품질기준 설정을 위한 광물조성 분석)

  • Choi, Jin-Beom;Jwa, Yong-Joo;Kim, Keon-Ki;Hwang, Gil-Chan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.4 s.50
    • /
    • pp.363-381
    • /
    • 2006
  • Mineral compositions of granitic rocks from Geochang, Pocheon, Iksan, and China were obtained by the modal analysis, CIPW norm calculations, and Rietveld quantitative analysis for stone specification of the Geochang granitic rocks. The Geochang granitic rocks show grey to dark in color and medium grained porphyritic texture. They mainly consist of quartz, plagioclase, alkali feldspar, and biotite. Among three different method for determining the mineral compositions of granitic rocks, normative compositions using X-ray fluorescence data are not appropriate for representing real mineral composition. Rietveld quantitative analysis using X-ray powder diffraction data is proved better method to determine exact mineral compositions than modal analysis using microscopic observation. Q-A-P diagram shows that the Geochang granitic rocks are typical granodiorite, whereas the granitic rocks of Pocheon, Iksan, and China are monzogranite, monzogranite to granodiorite, and granodiorite, respectively. Compared to China ones, the Geochang granitic rocks are nearly close to each other in mineral composition.