• Title/Summary/Keyword: 혈관 조영술

Search Result 336, Processing Time 0.03 seconds

Renal Sympathetic Denervation Induces Acute Myocardial Inflammation through Activation of Caspase-1 and Interleukin-1β (교감신경절제술(RDN) 후 caspase-1과 interleukin-1β 활성화로 인해 유발된 염증성 급성심근손상)

  • Lee, Dong Won;Kim, Il Young;Kwak, Ihm Soo
    • Journal of Life Science
    • /
    • v.28 no.2
    • /
    • pp.240-246
    • /
    • 2018
  • Efferent and afferent sympathetic nerves are closely related to the development of hypertension and heart failure. Catheter-based renal sympathetic denervation (RDN) is implemented as a strategy to treat resistant hypertension. We investigated whether RDN procedure causes inflammatory damage on myocardium in the early phase of sympathetic denervation. Twenty-five female swine were divided into 3 groups: normal control (Normal, n=5), sham-operated control (Sham, n=5), and RDN groups (RDN, n=15). The RDN group was further subdivided into 3 subgroups according to the time of sacrifice: immediately (RDN-0, n=5), 1 week (RDN-1, n=5), and 2 weeks (RDN-2, n=5) after RDN. There were no significant changes in the clinical parameters between the normal control and sham-operated group using contrast-media. In the myocardium, inflammatory cytokines, $IL-1{\beta}$ and $TNF-{\alpha}$ increased at the first week, and then decreased at the second week after RDN. Anti-inflammatory cytokine, IL-10 increased immediately, and then decreased at the second week after RDN. Caspase-1 activity and apoptosis-associated speck-like protein containing a caspase recruitment domain (ASC) expression increased immediately after RDN until the second week. However, nucleotide-binding oligomerization domain, leucine rich repeat and pyrin domain containing protein 3 (NLRP3) expression did not show any significant differences among the groups. The RDN can cause acute myocardial inflammation through activation of caspase-1 and $IL-1{\beta}$. We should pay attention to protecting against early inflammatory myocardial damage after RDN.

Improving Diagnostic Accuracy for Malignant Nodes and N Staging in Non-Small Cell Lung Cancer Using CT-Corrected FDG-PET (비소세포폐암에서 CT-보정 양전자단층촬영술을 이용한 악성 림프절 평가 및 N 병기 결정 성적 향상)

  • Lee, Eun-Jeong;Choi, Joon-Young;Lee, Kyung-Soo;Chung, Hyun-Woo;Lee, Su-Jin;Cho, Young-Seok;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kwon, O-Jung;Shim, Young-Mog;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.231-238
    • /
    • 2005
  • Purpose: We investigated prospectively whether the interpretation considering the patterns of FDG uptake and the findings of unenhanced CT for attenuation correction can improve the diagnostic accuracy for assessing malignant lymph node (LN) and N stage in non-small cell lung cancor (NSCLC) using CT-corrected FDG-PET (PET/CT). Materials & Methods: Subjects were 91 NSCLC patients (M/F 62/29, age: $60{\pm}9$ yr) who underwent PET/CT before in dissection. We evaluated the maximum SUV (maxSUV), patterns of FDG uptake, short axis diameter, and calcification of LN showing abnormally increased FDG uptake. Then we investigated criteria improving the diagnostic accuracy and correlated results with postoperative pathology. In step 1, in was classified as benign or malignant based on maxSUV only. In step 2, LN was regarded as benign if it had lower maxSUV than the cut-off value of step 1 or it had calcification irrespective of its maxSUV. In step 3, LN regarded as malignant in step 2 was classified as benign if they had indiscrete margin of FDG uptake. Results: Among 432 LN groups surgically resected (28 malignant, 404 benign), 71 showed abnormally increased FDG uptake. We determined the cut-off as maxSUV=3.5 using ROC curve analysis. The sensitivity, specificity, and accuracy for assessing malignant LN were 64.3%, 86.9%, 85.4% in step 1, 64.3%, 95.0%, 93.1% in step 2, and 57.1%, 98.0%, 95.4% in step3, respectively. The accuracy for assessing N stage was 64.8% in step 1, 80.2% in step 2, and 85.7% in step 3. Conclusion: interpreting PET/CT, consideration of calcification and shape of the FDG uptake margin along with maxSUV can improve the diagnostic accuracy for assessing malignant involvement and N stage of hilar and mediastinal LNs in NSCLC.

Results of Extracardiac Pericardial-flap Lateral Tunnel Fontan Operation (자가심낭막절편을 이용한 심외외측통로 Fontan 수술의 결과)

  • Park Han-Ki;Youn Young-Nam;Yang Hong-Seok;Yoo Byoung-Won;Choi Jae-Young;Park Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.281-288
    • /
    • 2006
  • Background: Extracardiac pericardial-flap lateral tunnel Fontan operation has theoretical advantage of growth potentiality of the extracardiac tunnels. The mid-term results of this technique and morphologic change of the lateral tunnel were studied. Material and Method: Clinical data was reviewed in 42 patients who underwent extracardiac pericardial-flap lateral tunnel Fontan operation between November 1993 and December 2004. The age was $2.8{\pm}1.5$ years and the body weight was $12.3{\pm}3.2$ kg. Extracardiac tunnel was constructed using the pedicled pericardium with the base undetached. By reviewing the follow-up cardiac angiograms, the diameter and the cross-sectional area of the lateral tunnel was compared to those of inferior vena cava. Result: There were four operative mortality cases (9.8%) and the causes of death were low cardiac output for all four cases. Postoperatively, five patients had prolonged pleural effusion longer than two weeks and one patient required a permanent pacemaker due to complete heart block. Follow-up was possible in 37 patients and the follow up duration was $3.8{\pm}2.2$ years. During that period, one patient died, of upper gastrointestional bleeding combined with heart failure and one patient died a sudden death of unknown cause. Two patients required reoperation due to subaortic stenosis and anastomosis site stenosis between inferior vena cava and lateral tunnel. In one patient, bradyarrhythmia was anew but there was no thromboembolic complication. The lateral tunnel showed growth in proportion to the size of the inferior vena cava. Conclusion: Extracardiac pericardial-flap lateral tunnel Fontan operation is relatively simple and safe. The mid-term result was favorable and the extracardiac tunnel showed potential for growth.

Clinical Significance of Reverse Redistribution on Tc-99m MIBI and T1-201 Myocardial Perfusion SPECT Images (Tc-99m MIBI와 T1-201 심근 SPECT에서 역재분포의 임상적 의의)

  • Song, Ho-Cheon;Bom, Hee-Seung;Kim, Ji-Yeul;Jeong, Myung-Ho;Gill, Kwang-Chae;Park, Joo-Hyung;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.95-103
    • /
    • 1996
  • Reverse redistribution(RRD) refers to a perfusion defect that develops or becomes more evident on rest imaging compared with the stress imaging. This phenomenon was not uncommonly noted on myocardial perfusion single photon emission computed tomography (SPECT). However, the clinical significance and pathophysiological mechanism of RRD were unclear. The aim of this study was to evaluate the incidence and clinical significance of RRD on either dipyridamole T1-201 or Tc-99m MIBI myocardial perfusion SPECT. RRD was defined as ${\geq}10%$ decrease in relative T1-201 and Tc-99m MIBI uptakes on rest images compared to the stress images or as an appearance of new perfusion defects on rest images. It was observed in both T1-201 (44/463, 9.5%) and Tc-99m MIBI (124/999, 12.4%) myocardial SPECTs similarly, with an overall incidence of 11.5%(168/1462). Many apparent)y unrelated disease groups showed the finding: post-revascularization(53.9%), coronary artery disease(24.6%), myocardial infarction(12.3%), and those with normal coro-nary arteries (9.2%). Clinical and angiographic characteristics of 65 consecutive patients who underwent coronary arteriography in 168 patients who had RRD on myocardial perfusion SPECT were reviewed. Tc-99m MIBI was used in 44 patients, and T1-201 was used in 21 patients. Of the 81 myocardial segments analyzed which showed RRD, 32 segments(39.5%) were in septum, 24(29.5%) in inferior wallL, 12(14.8%) in anterior wall, 7(8.7%) in apex and 6(7.4%) in lateral wall. There was no clear association between RRD and coronary arterial stenosis or Presence of collateral circulations. Ventriculographical wall motion was evaluated in 27 regions with RRD; it was normal in 12 regions, hypokinetic in 12 regions and dyskinetic in 3 regions. In 14 of 21 patients who showed RRD on T1-201 myocardial SPECT, T1-201 reinjection was performed immediately after the 3-4 hour redistribution studies. Ten of 14 (71.4%) showed enhanced T1-201 activity(${\geq}10%$ increased) after reinjection. We conclude that RRD is not related to mode of stress or radiopharmaceuticals. RRD might represent many inhomogeneous pathophysiological processes.

  • PDF

Comparison of Single- and Multi-Echo Susceptibility-Weighted Imaging in Detecting Cerebral Arteriovenous Shunts: A Preliminary Study (뇌동정맥단락 진단에서의 단일 에코 자화율 강조영상과 다중 에코 자화율 강조영상의 비교: 예비 연구)

  • Seung Wan Han;Jae Ho Shin;Yon Kwon Ihn;Seung Ho Yang;Jae Hoon Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.226-239
    • /
    • 2023
  • Purpose To compare the sensitivities of T2-weighted image (T2WI) and susceptibility-weighted imaging (SWI) in detecting cerebral arteriovenous fistula (AVF), cerebral arteriovenous malformation (AVM), and carotid-cavernous sinus fistula (CCF), and to qualitatively evaluate single-echo SWI (s-SWI) and multi-echo SWI (m-SWI) in characterizing vascular lesions. Materials and Methods From January 2016 to December 2021, cerebral angiography-proven lesions were recruited. The sensitivities of T2WI and SWI in detecting vascular lesions were compared using McNemar's test. Qualitative evaluations of s-SWI and m-SWI were categorized to be of poor, average, or good quality and compared using Fisher's exact test. Results A total of 24 patients (mean age: 61 years, 12 female, and 12 male) were enrolled. Twenty patients underwent s-SWI or m-SWI, and four patients underwent both. AVF, AVM, and CCF were diagnosed in 10, 11, and 3 patients, respectively. SWI demonstrated higher sensitivity compared to that of T2WI (82.1% vs. 53.6%, p = 0.013). m-SWI showed better image quality compared to that of s-SWI (good quality, 83.3% vs. 25.0%, p = 0.009). Conclusion SWI demonstrated a higher sensitivity for detecting cerebral arteriovenous shunts compared to that of T2WI. m-SWI exhibited better image quality compared to that of s-SWI in characterizing vascular lesions.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF