• Title/Summary/Keyword: 현장파일럿실험

Search Result 15, Processing Time 0.019 seconds

A Field Study on the Application of Pilot-scale Vertical Flow Reactor System into the Removal of Fe, As and Mn in Mine Drainage (현장 파일럿 실험을 통한 광산배수 내 Fe, As, Mn 자연정화처리 효율평가)

  • Kwon, Oh-Hun;Park, Hyun-Sung;Lee, JinSoo;Ji, Won Hyun
    • Economic and Environmental Geology
    • /
    • v.53 no.6
    • /
    • pp.695-701
    • /
    • 2020
  • This study aimed to monitor a pilot-scale vertical flow reactor (VFR) system being operated in long-term for water quality control of pH-neutral mine drainage containing Fe, Mn and As, discharged in D mine site. The treatment systems of VFR and zero manganese reactor (ZMR) consisted of sand/limestone, and steel slag/limestone, respectively. The systems were operated during about six months in order to evaluate their long-term treatment efficiency It was observed that both pH and alkalinity of mine drainage were remarkably increased and more than 98% of Fe, As and Mn ions was continuously removed during the tested period of time. In conclusion, the field results of this work demonstrated that the vertical flow reactor system can effectively treat mine drainage contaminated by Fe, As and Mn.

Evaluation of Cu Removal from Mine Water in Passive Treatment Methods : Field Pilot Experiments (자연정화 기반의 현장 파일럿 실험을 통한 광산배수 구리 정화효율 평가)

  • Oh, Youn Soo;Park, Hyun Sung;Kim, Dong Kwan;Lee, Jin Soo;Ji, Won Hyun
    • Economic and Environmental Geology
    • /
    • v.53 no.3
    • /
    • pp.235-244
    • /
    • 2020
  • Copper (Cu), one of the main contaminants in the mine drainage from the closed mine area, needs to be removed before exposed to environment because of its toxicity even in the low concentration. In this study, passive treatment based field pilot experiments using limestone and compost media were conducted during 9 months for enhancing Cu removal efficiency of the mine water treatment facility of S mine located in Goseong, Gyeongsangnam-do in South Korea. The pH increase and Cu removal efficiency showed high value at Successive Alkalinity Producing System ( SAPS) > Reducing and Alkalinity Producing System (RAPS) > limestone reactor in a sequence. The compost media using in SAPS and RAPS contributed to raise pH by organic material decomposition with generating alkalinity, thus, Cu removal efficiency increased. Also, experimental results showed that Cu removal efficiency was proportional to pH increase, meaning that pH increase is the main mechanism for Cu removal. Moreover, Sulfate Reduction Bacteria (SRB) was identified to be most activated in SAPS. It is inferred that the sulfate reduction reaction also contributed to Cu removal. This study has the site significance in that the experiments were conducted at the place where the mine water generates. In the future, the results will be useful to select the more effective reactive media used in the treatment facility, which is most appropriate to remediate mine water from the S mine.

Practical Study of Low-temperature Vacuum Swing Adsorption Process for VOCs Removal (휘발성 유기화합물 제거를 위한 저온 vacuum swing adsorption 공정의 실용화 연구)

  • Jeon, Mi-Jin;Pak, Seo-Hyun;Lee, Hyung-Don;Jeon, Yong-Woo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.3
    • /
    • pp.332-338
    • /
    • 2017
  • The objective of this work was to study the low temperature vacuum adsorption technology applicable to small and medium scale painting plants, which is the main emission source of volatile organic compounds. The low-temperature vacuum swing adsorption (VSA) technology is the way that the adsorbates are removed by reducing pressure at low temperature ($60{\sim}90^{\circ}C$) to compensate disadvantages of the existing thermal swing adsorption (TSA) technology. Commercial activated carbon was used and the absorption and desorption characteristics of toluene, a representative VOCs, were tested on a lab scale. Also based on the lab scale experimental results, a $30m^3min^{-1}$ VSA system was designed and applied to the actual painting factory to assess the applicability of the VSA system in the field. As a result of lab scale experiments, a 2 mm pellet type activated carbon showed higher toluene adsorption capacity than that of using 4 mm pellet type, and was used in a practical scale VSA system. Optimum conditions for desorption experiments were $80{\sim}90^{\circ}C$ and 100 torr. In the practical scale system, the adsorption/desorption cycles were repeated 95 times. As a result, VOCs discharged from the painting factory can be effectively removed upto 98% or more even after repeated adsorption/desorption cycles when using VSA technology indicating potential field applicabilities.

A Pilot Scale Biostimulation Study for In-situ Remediation of Organic Pollutants and PAHs contained in Coastal Sediment (연안 해역퇴적물에 함유된 유기오염물과 PAHs의 현장정화를 위한 파일럿 규모의 생물활성촉진연구)

  • Bae, Byung-Uk;Woo, Jung-Hui;Subha, Bakthavachallam;Song, Young-Chae
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.441-450
    • /
    • 2016
  • A pilot scale biostimulation experiment was performed under field conditions to degrade organic pollutants and PAHs (Polycyclic Aromatic Compounds) in contaminated coastal sediment. During the experiment, the seawater temperature around the sediment varied from $16.5^{\circ}C$ to $21^{\circ}C$, while the sediment pH was stable at 8.4-8.5. The experiment was conducted over a one year period with a control group and a sample group with a applied biostimulant composed of acetate, sulfate, and nitrate. Chemical oxygen demand decreased 39% in the control group and 79% in the sample group. Volatile solids were reduced from 15 to 7 g/kg in the control group and 2.5 g/kg in the sample group. Out of the 2-, 3- ,4- ,5-, and 6-rings of the 16 vital PAHs, the compound including naphthalene (2-ring), took 2 months to degrade completely, while the degradation efficiency was 55.6% in the control group during the same period. In the case of the 3-ring and 4-ring PAHs, complete degradation in the sample and 46% - 100% degradation in control was observed after one year of the experiment. The 5-ring and 6-ring PAHs were degraded to about 77%-100% in the sample group and 26%-87% in the control group during the one year of the experiment. The study results show that biostimulation is a very effective method to improve the degradation rate of organic pollutants and PAHs (Polycyclic Aromatic Compounds) in contaminated coastal sediment.

A Semi-Pilot Test of Bio-barrier for the Removal of Nitrate in Bank Filtrate (강변여과수의 질산성질소 제거를 위한 생물학적 반응벽체의 준파일럿 실험에 관한 연구)

  • Moon, Hee-Sun;Chang, Sun-Woo;Nam, Kyoung-Phile;Kim, Jae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.302-308
    • /
    • 2005
  • Nitrate is one of common contaminants frequently found in the bank filtrate. Biological autotrophic denitrification into permeable reactive barrier(PRB) system to reduce nitrate concentration in bank filtrate was implanted. The objectives of research are to investigate effect of inoculation, to evaluate alternative alkalinity sources, and to determine effect of hydraulic characteristics, such as retention time, flow rate on the performance of semi-pilot PRB system. Semi-pilot scale biological PRB system was installed using elemental sulfur and limestone/oyster shell as reactive materials near Nakdong River in Kyoungnam province, Korea. Nitrate concentration in bank filtrate was reduced by indigenous microorganisms in oyster shell as welt as by inoculating microorganisms isolated from the sludge of an anaerobic digester in a wastewater treatment plant. Oyster shell as well as limestone can be used as an alkalinity source. However, oyster shell resulted in suspended solids of effluent. As the flow rate in the system increased from 66 to 132 mL/min and accordingly the residence time decreased from 15 to 7.5 hours, nitrate concentration in effluent increased and nitrate removal efficiencies decreased from 75 to 58% at the fixed thickness of 80 cm of PRB.

Analysis of Fluid Flows in a High Rate Spiral Clarifier and the Evaluation of Field Applicability for Improvement of Water Quality (고속 선회류 침전 장치의 유동 해석 및 수질 개선을 위한 현장 적용 가능성 평가)

  • Kim, Jin Han;Jun, Se Jin
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • The purpose of this study is to evaluate the High Rate Spiral Clarifier(HRSC) availability for the improvement of polluted retention pond water quality. A lab scale and a pilot scale test was performed for this. The fluid flow patterns in a HRSC were studied using Fluent which is one of the computational fluid dynamic(CFD) programs, with inlet velocity and inlet diameter, length of body($L_B$) and length of lower cone(Lc), angle and gap between the inverted sloping cone, the lower exit hole installed or not installed. A pilot scale experimental apparatus was made on the basis of the results from the fluid flow analysis and lab scale test, then a field test was executed for the retention pond. In the study of inside fluid flow for the experimental apparatus, we found out that the inlet velocity had a greater effect on forming spiral flow than inlet flow rate and inlet diameter. There was no observable effect on forming spiral flow LB in the range of 1.2 to $1.6D_B$(body diameter) and Lc in the range of 0.35 to $0.5L_B$, but decreased the spiral flow with a high ratio of $L_B/D_B$ 2.0, $Lc/L_B$ 0.75. As increased the angle of the inverted sloping cone, velocity gradually dropped and evenly distributed in the inverted sloping cone. The better condition was a 10cm distance of the inverted sloping cone compared to 20cm to prevent turbulent flow. The condition that excludes the lower exit hole was better to prevent channeling and to distribute effluent flow rate evenly. From the pilot scale field test it was confirmed that particulate matters were effectively removed, therefore, this apparatus could be used for one of the plans to improve water quality for a large water body such as retention ponds.

Intelligent Collision Prevention Technique for Construction Equipment using Ultrasound Scanning (초음파 스캐닝을 활용한 지능형 건설기계 충돌방지 기술)

  • Lee, Jaehoon;Hwang, Yeongseo;Yang, Kanghyeok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2021
  • According to the Ministry of Employment and Labor's statistics on occupational fatalities in South Korea, more than half of the fatalities in the past five years have occurred in the construction industry. The stuck-by and caught-in-between accidents associated with construction equipment is the major source of fatalities from construction sites. In order to prevent such accidents in construction sites, the government has spent lots of efforts including proposing the "special law on construction safety" and encouraging the implementation of new technology for accident prevention. However, numerous accidents are still occurred at construction sites and further efforts are still required. In this manner, this study developed a collision prevention technique that can prevent collision between equipment and worker by recognizing location and type of the nearby objects through ultrasound scanning. The study conducted a pilot experiment and the analysis results demonstrate the feasibility of achieving high performance in both object recognition and location estimation. The developed technique will contribute to prevent collision accidents at construction sites and provide the supplemental knowledge on developing automated collision prevention system for construction equipment.

A Study on Performance Evaluation for the Bio-retention Non-point Source Pollution Treatment System (생물 저류 방법 적용을 통한 비점오염원 처리시설의 성능평가에 관한 연구)

  • Lee, Jang-Soo;Park, Yeon-Soo;Cho, Wook-Sang
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.295-299
    • /
    • 2013
  • This study was purposed and performed to evaluate removal efficiency of non-point source pollution in the process and system based on bio-retention design criteria regulated by EPA. Basic Column Reactors (BCR) were prepared for optimal determinations of inflow rate of first rainfall runoff and composition and ratio of soil layers. Removal efficiencies of non-point source pollution from synthetic runoff and real first rainfall runoff, directly sampled from motor way and parking lot, were analyzed, respectively. Removal efficiency of SS, BOD, COD, T-N, and T-P were all shown to be more than 80%.

Practical Application of Mn-Cu Metal Catalyst for the Removal of Acetaldehyde (아세트알데히드 제거를 위한 Mn-Cu 금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Digital Convergence
    • /
    • v.10 no.8
    • /
    • pp.201-210
    • /
    • 2012
  • Because sensing odor varies depending on each person, even if the odor is released in line with the legal emission permission concentration levels, it can still become a social issue if a civil complaint is made. The purpose of this research is to study the possibility of putting Mn-Cu metallic oxide catalysts into practical use to economically eliminate acetaldehyde which produces a odor in the industrial process. An optimal operating parameter to eliminate acetaldehyde was deduced through a performance evaluation in the research laboratory and the performance was verified by applying the parameter into an actual facility as an on-the-site experiment through a Scale-up of pilot size. The operating temperature of the metallic oxide catalysts researched so far was at the minimum close to $220^{\circ}C$, and the $220^{\circ}C$ elimination efficiency was 50% or below. However, having experimented by using a Mn-Cu metallic oxide catalyst in this research, optimum elimination efficiency showed when space velocity (GHSV) was equal to or below 6,000 $hr^{-1}$. The average elimination efficiency was 61.2% when the catalyst controlling temperature was $120^{\circ}C$, 93.3% when the catalyst controlling temperature was $160^{\circ}C$, and 94.9% when catalyst controlling temperature was $180^{\circ}C$, thereby reflecting high elimination efficiency. The specific surface area of the catalyst was $200m^2/g$ before use, however, was reduced to $47.162m^2/g$ after 24 months and therefore showed that despite the decrease in specific surface area as time passed, there was no significant influence on the performance. Having operated Mn-Cu metallic oxide catalyst systems for at least two years on a site where there was no inflow of toxins like sulfur compounds and acidic gases, we were able to confirm that elimination efficiency of at least 90% was maintained.

Implementation of Infinite Boundary Condition Considering Superposed Theory on SVE Remediation System (토양증기추출복원 시스템에서 중첩이론을 고려한 무한 경계조건 실행)

  • Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.9-16
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. With this approach, the real bounded system is replaced for the purposes of analysis by an imaginary system of infinite areal extent. The boundary conditions for the contaminant remediation model test include constant head and no flow condition. Due to these parallel boundaries conditions, image wells should be developed in order to maintain the condition of no flow across the impermeable boundary. It is also assumed that the flow is drawdown along the constant head boundary condition. The factors contributing to the difference between the theoretical and measured pressure heads were also analyzed. The flow factor increases as the flow rate is increased. The flow rate is the most important factor that affects the difference between the measured and theoretical pressure heads.

  • PDF