Analysis of Fluid Flows in a High Rate Spiral Clarifier and the Evaluation of Field Applicability for Improvement of Water Quality  

Kim, Jin Han (Department of Environmental Engineering, School of Urban and Environmental Engineering, Incheon National University)
Jun, Se Jin (Department of Chemical & Environmental Technology, Inha Technical College)
Publication Information
Journal of Wetlands Research / v.16, no.1, 2014 , pp. 41-50 More about this Journal
Abstract
The purpose of this study is to evaluate the High Rate Spiral Clarifier(HRSC) availability for the improvement of polluted retention pond water quality. A lab scale and a pilot scale test was performed for this. The fluid flow patterns in a HRSC were studied using Fluent which is one of the computational fluid dynamic(CFD) programs, with inlet velocity and inlet diameter, length of body($L_B$) and length of lower cone(Lc), angle and gap between the inverted sloping cone, the lower exit hole installed or not installed. A pilot scale experimental apparatus was made on the basis of the results from the fluid flow analysis and lab scale test, then a field test was executed for the retention pond. In the study of inside fluid flow for the experimental apparatus, we found out that the inlet velocity had a greater effect on forming spiral flow than inlet flow rate and inlet diameter. There was no observable effect on forming spiral flow LB in the range of 1.2 to $1.6D_B$(body diameter) and Lc in the range of 0.35 to $0.5L_B$, but decreased the spiral flow with a high ratio of $L_B/D_B$ 2.0, $Lc/L_B$ 0.75. As increased the angle of the inverted sloping cone, velocity gradually dropped and evenly distributed in the inverted sloping cone. The better condition was a 10cm distance of the inverted sloping cone compared to 20cm to prevent turbulent flow. The condition that excludes the lower exit hole was better to prevent channeling and to distribute effluent flow rate evenly. From the pilot scale field test it was confirmed that particulate matters were effectively removed, therefore, this apparatus could be used for one of the plans to improve water quality for a large water body such as retention ponds.
Keywords
High Rate Spiral Clarifier; flow pattern; CFD; field applicability;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cockx A, Do-quang Z, Line A, and Roustan M (1999). Use of computational fluid dynamics for simulating hydrodynamics and mass transfer in industrial ozonation towers. Chem. Eng. Sci. 54(21), pp. 5085-5090.   DOI   ScienceOn
2 Deglon DA and Meyer CJ (2006). CFD modelling of stirred tanks: numerical considerations. Miner. Eng. 19(10), pp. 1059-1068.   DOI   ScienceOn
3 Alviti Steven R (2003). Waste water treatment system. U.S. patent. Patent No. US 6,620,317 B2.
4 Anflux (2004). ANSYS workbench release 9.0. Canonsburg, Pennsylvania, U.S.A.
5 Arnaud Johnny (2003). Apparatus for mixing fluids. U.S. patent. Patent No. US 6,669,843 B2.
6 Cao Z, Wiley DE, and Fane AG (2001). CFD simulations of net-type turbulence promoters in a narrow channel. J. of Membr. Sci. 185, pp. 157-176.   DOI   ScienceOn
7 McCabe WL, Smith JC, and Harriott P (2005). Unit operations of chemical engineering. McGraw-Hill, Boston.
8 Kim, YC, Jeong, H-Y, and Lee, JW (2003). Evaluation of the nitrogen reduction in Water hyacinth ponds coupled with waste stabilization ponds, J. of the Korean Society of Civil Engineers, 23(5B), pp. 425-436.
9 Lee, KS, Jang, JR, Kim, YK, and Park, BH (1999). A study on the floating island for water quality improvement of a reservoir, Korean J. of Environmental Agriculture, 18(1), pp. 77-82.
10 Leung Wai On (2002). Vortex sewage disposal apparatus. U.S. patent. Patent No. US 6,358,415 B1.
11 Panneerselvam R, Savithri S, and Surender GD (2009). CFD simulation of hydrodynamics of gas-liquid-solid fluidised bed reactor. Chem. Eng. Sci., 64(6), pp. 1119-1135.   DOI   ScienceOn
12 Vakili, MH and Nasr, EM (2009). CFD analysis of turbulence in a baffled stirred tank, a three-compartment model. Chem. Eng. Sci. 64, pp. 351-362.   DOI   ScienceOn
13 Yang, HM (2003) Phosphorus removal rate of a surface-flow treatment wetland system constructed on floodplain during its initial operating stage, Korean J. of Environmental Agriculture, 22(4), pp. 251-254.   DOI
14 Kim, JH, Jun, SJ, Lim, JY, Song, YM, Yoo, KW, Jung, JT, and Park, JH (2010). A study on the improvement of water environment in retention pond by seawater flocculation and fenton oxidation, J. of Korean Wetlands Society, 12(1), pp. 75-82.
15 Kessler DP and Greenkorn, RA (1999). Momentum, heat, and mass transfer fundamentals, Marcel Dekker, New York.
16 Koo, WS, Yoon, CG, Ham, JH, Kim, HC, and Shin, HB (2004). Analysis of Water quality improvement as a period of surface constructed wetlands and Feasibility study on the combined of wetlands and pond, Proceedings of Fall Joint Conference 2004, Korean Society on Water Quality and Korean Society of Water and Wastewater, Nov. 6, 2004, Daeduk Convention Town, Korea, pp. C1-C10.
17 Choi BS, Wan B, Philyaw S, Dhanasekharan K, and Ring TA (2004). Residence time distributions on a stirred tank: comparison of CFD predictions with experiment. Ind. Eng. Chem. Res 43(20) pp. 6548-6556.   DOI   ScienceOn