• Title/Summary/Keyword: 현장침투실험

Search Result 122, Processing Time 0.026 seconds

A Study on Normal Range of Surface Deflection for Epoxy Asphalt Pavement using Light Weight Deflectormeter (LWD를 활용한 에폭시 아스팔트 포장의 정상 표면처짐 범위 연구)

  • Park, Ki Sun;Kim, Kyung Nam;Kim, Nak Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.229-236
    • /
    • 2015
  • In this study, the resilient modulus test and Light Weight Deflectormeter (LWD) test were conducted to simulate the moving vehicle load for the evaluation of the internal failure of epoxy asphalt pavement. The Measured displacement in the resilient modulus test of epoxy asphalt concrete showed very little residual deformation under repeated loads unlike the conventional asphalt. Therefore, the test results were evaluated as a normal state due to its similarity with elastic deformation. The deflection results from the resilient modulus tests were converted to the surface deflection modulus and the normal range of surface deflection modulus was estimated applying LWD measurement of 1 SIGMA level. Internal failure of pavements were estimated using the suspicious failure range at $60^{\circ}C$ and hysteresis. Internal moisture penetration and a decrease in bonding were observed in partial areas at $140{\mu}m$ of surface deflection. However, the areas showed inflection points in the hysteresis. Field investigation by suggested criterion indicated a high degree of accuracy.

Evaluation of Durability Characteristics of High Performance Shotcrete Using Fly Ash (폐석탄회를 이용한 고성능 숏크리트의 내구특성 평가)

  • Park, Cheol-Woo;Lee, Hyeon-Gi;Kang, Tae-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.305-311
    • /
    • 2010
  • The industrial by-product market has increased at a geometric rate worldwide with the rapid economic growth. At present time, conventional disposal methods of industrial by-products in Korea including landfill, incineration and storage already have reached their limits. In this study, the industrial by-products such as fly ash and silicafume were used as mineral admixtures, which are commonly added to concrete mix to inhance the economic efficiency, long-term strength and durability of concrete, to determine the optimized mix proportion of high performance shotcrete. Through the series of tests (compressive strength test, accelerated chloride ion penetration test, measurement of chloride diffusion coefficient). The results of the study showed that the proposed mix proportions satisfied the requirements of domestic as well as international guidelines for shotcrete, with a higher durability than the existing shotcrete.

A Study on the Sediment Volume Change and Two-dimensional Deposited Characteristics of Pumping-dredged Soil (준설토의 체적변화 및 2차원 퇴적특성에 관한 연구)

  • 김형주;이민선;이용주;김대우
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.155-165
    • /
    • 2003
  • A series of one-dimensional cylinder sedimentation test, seepage consolidation test and two-dimensional deposition model test were conducted to examine the characteristics of deposition and volume change of dredged soils containing the high water content, and these experimental results were compared with the sedimentary conditions of actual dredged-reclaimed fields to obtain the relations of a volume change by settling what is required for design. In addition, the change of water content and the distribution of fine grained soils after sedimentation were investigated. Thus, it was concluded that deposition height increased lineary as substantial soil volume increased, and also the elevation of interface increasea proportionately at both the starting time and the finishing time of virtual self-weight consolidation in one-dimensional sedimentation. Furthermore, the two-dimensional model test results were shown to describe the plain distribution of water content and fine grained silt where dredged soil was deposited by two dimensional flowing, and the water content was distributed to wide range from the minimum water content 30% to maximum 180% according to the passed amount of №200 sieve percentage.

Behavior of Fill Dam Subjected to Continuous Water Level Change and Overflow (지속적 수위변동 및 월류에 따른 저수지 제체의 거동 연구)

  • Lee, Chungwon;Maeng, Youngsu;Kim, Yongseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.41-48
    • /
    • 2014
  • In this study, the behavior of fill dam with continuous water level change considering velocity changes via centrifugal model test was investigated. In addition, the collapse of fill dam due to the overflow was also experimentally simulated. The experimental results demonstrate that the pore water pressures and displacements vary in proportion to the water-level-change velocity, and the displacement increment is independent to the water-level-change velocity. Also, it is confirmed that the continuous water level change induces to the progress of fill-dam deformation due to displacement accumulation and the fill-dam stability dramatically degrades owing to the overflow. Hence, the real-time monitoring of pore water pressures and displacements of fill dam, and the control of water level in heavy rain through the countermeasure such as opening sluice gates are needed to ensure the stability of fill dam.

ILLUDAS-NPS Model for Water Quality in Urban drainage (도시유역의 수질해석을 위한 ILLUDAS-NPS 모형)

  • Kim Tae-Hwa;Lee Jong-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.482-486
    • /
    • 2005
  • 불투수지역의 증가에 따른 도시지역의 비점오염원 해석 및 예측은 수자원 관리측면에서 중요성이 증가하고 있다. 그러나, 실측자료의 부족, 오염물질 발생경로의 불명확, 간헐성, 강우 및 유역특성에 따라 오염부하량 및 첨두농도 등의 변화가 심하므로 인하여 연구에 어려움이 많은 실정이다. 이를 극복하기 위해서는 장기적인 자료수집과 국내실정에 맞는 모형개발이 이루어져야 할 것이다. 따라서, 본 연구에서는 초기강우에 의한 수질항목별 오염부하량 및 농도계산이 가능한 ILLUDAS-NPS 모형을 개발하였다. 본 모형은 국내의 도시지역 유출해석에 주로 사용되는 ILLUDAS 모형에 건기 및 우기시의 수질해석 과정들을 추가하여 해석되어 진다. 건기시의 경우 유량 및 수질 계산은 계수지정법을 사용하였으며, 우기시의 경우 유량계산은 기존 ILLUDAS 모형의 알고리즘을 이용하였고, 수질 계산은 일일 오염물 축적법과 쓸림방정식을 적용하여 계산시간별 오염물질 부하량 및 농도 등을 계산하였다. 모형의 검정을 위하여 홍제천 시험유역의 총 3가지 강우사상을 대상으로 검토한 결과 총부하량, 첨두농도, 첨두농도 발생시간 등에서 전반적으로 실측치와 유사한 결과를 얻을 수 있었다. 또한, ILLUDAS-NPS 모형과 SWMM, STORM 등의 기존 도시유출$\cdot$수질 모형들에 의한 결과들의 비교에서 SWMM 모형과 다소의 차이는 있으나 대부분 잘 일치함을 확인할 수 있었다. 추후, 합리적이고 보다 정확한 비점오염 해석을 위하여 도시지역의 건거시 오염물질의 축적율 및 초기강우에 의한 오염물질 쓸림량 등에 관한 실험 및 현장자료 축적이 필요하다.월이 긴 것으로 나타났다. 이러한 현상은 유입수가 저수지로 유입되면서 초기수위가 높은 경우에 운동량이 상대적으로 많이 소멸되기 때문으로 판단된다. 또한 탁수층의 두께도 8월 성층의 경우가 상대적으로 큰 것으로 나타났다. 이는 중층의 8월 수온분포 또는 밀도분포가 상대적으로 균일하기 때문에 연직방향 이송$\cdot$확산이 많이 이루어졌기 때문으로 판단된다.이는 토성간의 침투속도 및 투수속도의 경향이 반영된 것이다. 경사에 따라서는 경사도가 증가할수록 지수적으로 감소하였으며 $10\% 경사일 때를 기준으로 $I(mm)=I_{10}{\times}1.17{\times}e^{-0.0164s(\%)}$로 나타났다. 같은 조건에서 강우량과 유거수의 관계는 $Ro_{10}(mm)=5.32e^{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10

  • PDF

The Evaluation of Seepage Characteristics in Reinforced Embankment Constructed on Low Permeable Clay Layer Through Centrifuge Model Tests (원심모형실험을 활용한 투수성이 낮은 기초지반에 위치한 보축 제방에서의 침투 거동)

  • Jin, Seok-Woo;Choo, Yun-Wook;Kim, Young-Muk;Kim, Dong-Soo;Im, Eun-Sang
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.27-39
    • /
    • 2012
  • In this paper, a series of centrifuge tests were performed to evaluate the seepage characteristic of reinforced embankment. The centrifuge models simulated an actual embankment reinforced by enlargement of levee cross-section. The centrifuge models have the same conditions except the locations of enlargement with low permeable material : water-side and land-side. In addition, the prototype embankment is constructed on low permeable clay layer. In the case of water-side reinforcement, the reinforced zone makes water head down and the saturated zone of embankment propagates slowly. In the case of land-side reinforcement embankment, the saturated zone enlarged relatively faster but the amount of exit water at land-side toe was very small because of the land-side reinforcement zone. The low permeable clay foundation layer was being continuously saturated by the inflow from the embankment as well as the uplift flow from the permeable layer induced by the excess pore water pressure.

Slope Stability Analysis of Unsaturated Soil in Debris-Flow Occurrence Slopes (토석류 발생 사면의 불포화토 사면안정해석)

  • Kwak, Cheol-Soo;Park, Byung-Soo;Yoo, Nam-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.9
    • /
    • pp.23-30
    • /
    • 2012
  • This paper is research results of slope stability analysis associated with seepage infiltration for unsaturated soil in debris-flow occurrence slopes. Site investigations were carried out in two slopes, located at Inje in Kangwon province where debris flow occurred in 2006 and at Yangpyung in Kyeunggi province where it occurred in 2010. For unsaturated soil sampled at the zone of debris-flow initiation, soil water characteristic curves with tempe pressure cells and shear strength parameters with newly designed shear strength apparatus were obtained respectively. The commertially available software SEEP/W was used to analyze seepage infiltration in unsaturated soil, based on their properties obtained from test results and the actual rainfall data at the moment of debris flow occurrence, and slope stability analysis with the program of SLOPE/W, associated with results of seepage analysis, was performed to simulate slope failure. As results of this research, seepage infiltration to unsaturated soil due to intensive rainfall was found to cause increase of ground water table as well as degree of saturation. Through this research slope stability analysis for unsaturated soil, considering the actual rainfall characteristic, might be a reasonable method of investigating characteristics of debris flow behavior, in particular, the moment of debris flow occurrence.

Condition Evaluation of Bare Concrete Bridge Decks (콘크리트 노출 교량 바닥판의 상태평가 기법)

  • Suh, Jin-Won;Rhee, JI-Young;Seo, Sang-Gil;Shin, Jae-In
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • In 1980's, the concrete bridge decks were constructed with 4cm wearing surface layer instead of asphalt concrete overlays. After about 15 year service periods, deteriorations were appeared on the surfaces of highway bridge decks. Various field NDTs and lab tests were done to analysis the cause of the deterioration on the concrete deck surface. The main cause was the corrosion of rebars with thinner concrete top cover than the design value. The rebars with thinner concrete top cover was earlier corroded by penetrated chloride ions. If the appropriate top cover could be achieved, the bare concrete bridge decks can be used without earlier deteriorations.

Evaluation on Mechanical Performance and Chloride Ion Penetration Resistance of On-Site Shotcrete Made with Slurry-Type Accelerator (슬러리형 급결제를 활용한 현장적용 숏크리트의 역학적 성능 및 염해저항성 평가)

  • Kim, Hyun-Wook;Yoo, Yong-Sun;Han, Jin-Kyu;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.507-515
    • /
    • 2018
  • The purpose of this research is to develop a slurry-type accelerator that contains various beneficial properties such as reduction of dust generation, lower alkalinity, early age strength development, etc., and uses such slurry type accelerator to produce high performance shotcrete that present excellent resistant against chloride ion penetration. In this work, shotcrete mixtures of 0.44 and 0.338 water-to-binder ratio (w/b) were produced at construction site using slurry-type accelerator. The mechanical properties and chloride ion penetration resistance of such shotcrete (including base concrete) were evaluated. According to the experimental results, the slurry-type accelerator was successfully used to produce both w/b 0.44 and 0.338 shotcretes. The 1 day and 28 day compressive strength of shotcrete were found to be closer to or higher than 10MPa and 40MPa, respectively. The w/b 0.338 shotcrete that used 40% replacement of blast furnace slag showed lower compressive strength than w/b 0.44 shotcrete without any mineral admixture at 1 day. However, the compressive strength with 40% blast furnace slag increased significantly at 28 day. Moreover, there was more than 50% increase in chloride ion penetration resistance with blast furnace slag, showing its strong potential for higher performance shotcrete application.

The Strength and Characteristic of PCC Bottom Ash (석탄재의 강도 특성에 관하여)

  • Shin, Sanguok;Sanjeev, Kumar;Jung, Teuok;Shin, Bangwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2007
  • Coal combustion by-product (CCB) bottom ash, obtained from burning of pulverized coal, has physical properties which are similar to that of natural sand with particle sizes ranging from fine gravel to fine sand. Several studies have been completed to utilize pulverized coal combustion (PCC) bottom ash as a partial or full replacement of fine aggregate in cement concrete products. The objectives of this study were to develop air-entrained concrete composites using PCC bottom ash from burning of Illinois coal and to demonstrate the use of these composites on real-world projects. The results obtained show that the compressive, splitting-tensile, and flexural strengths of concrete composites is slightly lower than that of conventional concrete are early curing ages. However, after 60 days of curing, the strength of concrete composites is either equal to or slightly higher than that of an equivalent conventional concrete. The concrete composites showed lower resistance to chloride ion penetrability than that of an equivalent conventional concrete at early curing ages. However, after 28 days of curing, concrete composites showed better resistance to chloride ion penetrability compared to that of an equivalent conventional concrete.

  • PDF