• Title/Summary/Keyword: 현장재하시험

Search Result 325, Processing Time 0.025 seconds

Safety Evaluation through Field Load Test of RC Slab Bridge (RC 슬래브 교량의 현장재하시험을 통한 안전성 평가)

  • Cho, Han-Min
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

Application of The Bi-Directional Pile Load Test for The Yield Capacity of Rock Socketed Pile (양방향재하시험을 활용한 암반근입 말뚝의 항복하중 판별방법)

  • Kim, Jong-Woong;Jang, Kyung-Jun;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.526-532
    • /
    • 2009
  • 말뚝의 정재하시험을 통하여 항복하중 및 극한하중을 판별하는 다양한 방법이 제안되어 왔다. 말뚝의 지지력은 주면마찰력과 선단지지력의 합으로 나타내어 왔으나 말뚝 재하시험을 통한 항복 하중 및 극한하중의 판별법은 대체로 총 침하량에 대해 판별하거나 재하하중-침하 그래프로부터 산정되는 경우가 대표적이다. 본 연구에서는 현장 대구경 양방향 재하시험 결과를 활용하여 말뚝의 주면부와 선단부로 나누어 항복하중을 판별할 수 있는 방법을 제안하고자 한다.

  • PDF

A Research for Computation of Bearing Capacity and Settlement of Foundation Considering Scale Effect in Weathered-granite Layer (화강풍화토에서 Scale Effect를 고려한 기초의 지지력 및 침하량 산정에 관한 연구)

  • 박용부;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.131-139
    • /
    • 2004
  • When calculating bearing capacity and settlement of actual foundation from plate test result fur design and construction of shallow foundation, scale effect should be considered. But, adequate guide and test result of scale effect were not prepared yet in Korea. So, to analyze the relations of bearing capacity and settlement as the difference of loading plate sizes, model test and field loading test were performed with different loading plate on weathered-granite layer. Model tests were conducted with water content, compaction number, saturated unit weight and plate size(Dl5, 25cm) in soil-box$(2,000\times 2,000\times 1,000mm)$ formed soil layer. Field loading tests were carried out with diameters of loading plate$(D15, 25, 30, 40, 75\times 75, 140\times 210cm)$ on the same soil condition. Finally, we presented the prediction formula of bearing and settlement for computating scale offset in design of shallow foundation through result analysis of load test and numerical simulation on weathered soil and rock.

PHC 말뚝의 항타 시공성에 관한 연구

  • 이인모;김상균
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.06a
    • /
    • pp.1-13
    • /
    • 1992
  • 본 연구에서는 일반 PC 말뚝과는 달리 제작시 실리카(silica) 재료를 사용하고 중기양생후 고온,고압의 추가양생(autoclave curing)을 실시 함으로써 말뚝자체의 강성을 높인 PHC 말뚝의 항타 시공성을 컴퓨터 프로그램을 이용하여 파악하였다. 일반적으로 임의의 지반조건, 항타장비에 따른 컴퓨터 프로그램의 실행결과는 PHC 말뚝이 PC 말뚝에 비해 항타장비에 의해서 발휘되는 타격에너지에 대해 보다 큰 저항력을 가지므로 설계지지력을 크게 얻을 수 있으며 항타장비의 선정에 있어서도 보다 큰 효율을 지닌 장비의 선정이 가능하여 경제적인 항타작업을 수행하는데 유리함을 보였다. 이와같은 결과를 실제 현장에서의 말뚝 항타시공을 실시한 후 항타기록 및 재하시험 결과와 비교검토 하였는데 본 연구결과와 재하시험 결과가 잘 일치함을 보였다.

  • PDF

Evaluation of Applicability of Cable Force Monitoring System of Cable-stayed Bridge by Field Loading Test (재하시험을 통한 사장교의 케이블 장력 모니터링 시스템의 적용성 평가)

  • Kim, Jeong-Hoon;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.205-213
    • /
    • 2009
  • This study was planned to develop monitoring system of cable force to resolve cable force of cable-stayed bridge efficiently in a long-term plan. In the proposed monitoring system, firstly data are sampled from real-time acceleration record, secondly these sampled data are frequency analyzed by using the FFT(Fast Fourier Transform) algorism and lastly the analyzed results are averaged and generalized. For evaluating the applicability of this monitoring system, field loading test has performed in real cable-stayed bridge. In comparison with cable force by field manual calculation and cable force of monitoring system by semi-automatic calculation, the difference of calculated cable forces has within 1% error range and it is acceptable range. Additionally within negligible 5% error range of difference has occur between field manual calculation and monitoring system by automatic calculation. so monitoring system in this study has been verified to be reliable.

Estimation of Bearing Capacity for In-Situ Top-Base Method by Field Experimental Plate Load Test (현장평판재하시험에 의한 현장타설형 팽이말뚝기초의 지지력산정)

  • Shin, Eun-Chul;Ahn, Min-Hye
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • The problems like a deterioration of loading bearing capacity, an exaggeration of settlement and lateral deformation are able to be generated, meanwhile structures are built in soft ground. Top-Base method is belonged to a rigidity mat foundation method which is used to surface treatment of soft ground. This method makes an effect to increase the bearing capacity of foundation using friction force, and prevent the differential settlement. Further more, the In-Situ Top-Base method has advantages in the phase of economic effect by reduction of the construction cost and offers an expediency on construction comparing with precast products. This paper presents the way of the estimation of bearing capacity for In-Situ Top-Base method through field plate load test in soft ground. It utilizes the results to a future design by analyzing the properties in the existing study and designs through these analysis and calculating the top-base method's reasonable range.

A Study on Bearing Capacity of Cast-In-Place Pre-Founded Columns in Top Down Construction Sites (Top Down 공사현장에 적용되는 현장타설 선기초기둥의 지지력에 관한 연구)

  • Byun, Yoseph;Jung, Kyoungsik;Kim, Jongho;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.55-61
    • /
    • 2011
  • Recently, a concept of the downtown area was progressively extended by improvement of rapid transportation system and development of the most advanced telecommunication industries. And underground has become bigger in addition deeper, Excavation methods which construct a structure were changed according to construction environments. Top Down methods which are continuous with architectural plan differ from existing excavation methods innovatively, pre-founded column is an important factor for construction methods, duration, expenses. Therefore, this study considers application by investigative methods according to comparison, analysis on loading test result of on site inspection and estimated results of bearing capacity for structure pre-founded column. As a result, almost designing eclipse appeared prior value which didn't arrive result of load test. Also, evaluate permanent load for the compressive stress acting on head of cast-in-place after basic structure was installed. Then, applying stress generally is reduced by confining effect with foundation.

A Study on the Improvement of Pile Foundations Based on the Analysis of Field Case Studies (말뚝기초 시공사례 실태분석을 통한 개선방안 연구)

  • Woo, Jae-Gyung;Lee, Su-Gon;Lee, Byok-Kyu;Jang, Seung-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.81-92
    • /
    • 2012
  • In this study, in-depth site investigation related to design and construction of pile foundation was carried out, especially with respect to 103 large-scale bridges located in South Korea. As a result, the depths and location of investigation was unsatisfactory at the foundation investigation process. Moreover, pile load tests were not performed when the capacity of the file is calculated in planning phase, and it was difficult to determine the load capacity limit due to the fact that loading capacity was not specified in pile-loading test. The design criteria related to pile foundation does not reflect the reality of the construction site, and that causes over design, and economic inefficiency in budget. Therefore, the purposes of this study is to review case studies related to the bearing capacity of pile foundations and suggest improvements in the construction specifications.