• Title/Summary/Keyword: 현장실증시험

Search Result 127, Processing Time 0.032 seconds

Quantitive Evaluation of Reproducibility of Embankment for Full Scale Test through Statistical Analysis of Physical Properties of Soil (지반물성치 통계분석을 통한 실규모 시험용 제방축조의 재현성에 관한 정량적 평가)

  • Lee, Heemin;Moon, Junho;Kim, Minjin;Kim, Younguk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.6
    • /
    • pp.19-23
    • /
    • 2022
  • For the substantiation and verification of studies related to the construction of a levee using riverbed soil, real-scale levee construction and experimental studies are essential. One of the most important factors in the experimental study is the reproducibility of the multiple levees with the same initial conditions. Quantitative analysis of the reproducibility should be presented. In this study, a number of physical properties (specific gravity test, sieving test, liquid-plastic limit test, compaction test, on-site Density test) for multiple embankments built with fine-grained bed soil was obtained. The collected data then used to obtain the possibility of reproducing levee through statistical analysis to suggest a process of indicating a numeric initial condition of the real-scale test. As a result of statistical analysis to verify the aforementioned process, it was confirmed that it was possible to quantitatively evaluate the reproducibility of the construction under the same conditions of embankments. This is expected to be a basic data for a full-scale embankment test using riverbed soil including other soil based real-scale tests.

A Pilot Test for the Utilization of Road Subsoil of the Tertiary Mudstone in Pohang Basin (포항분지 제3기 이암의 도로 노체 활용을 위한 현장시험)

  • Gong, Jeong-Sik;Baek, In-Woo;Kim, Jae-Gon;Song, Young-Suk;Kim, Tae-Hyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2021
  • The purpose of this study is to present the possibility a utilization of the tertiary mudstone in Pohang as road subsoil material through pilot experiments on the road embankment structure. This mudstone is an unconsolidated rock that is distributed in the soft rock sedimentary layer, the tertiary layer of the Cenozoic, and causes physical problems such as slaking, swelling, and reduced shear strength and chemical problem like acid drainage. In order to solve various complex problems, an laboratory mixing test was conducted, and the optimal mixing conditions of the tertiary mudstone (90%), composite slag (steel making 70%, blast furnace 30%), and neutralization and coating agent treatment were derived. In order to prove its utilization, a real-scale road embankment structure was constructed and tests were conducted for each section. The pre-processing section is stable due to the design of optimal mixing conditions, while in post-processing section, natural weathering proceeded rapidly, and structural problems were concerned. Since the effect of neutralizing and coating agents was confirmed in temporary-staking section, the neutralizing and coating agents can be applied during the temporary storage period.

A Comparison on the Effect of Soil Improvement Methods for the Remediation of Heavy Metal Contaminated Farm Land Soil (중금속 오염 농경지 토양의 복원을 위한 토량개량법의 효과 비교)

  • Yun, Sung-Wook;Jin, Hae-Geun;Kang, Sin-Il;Choi, Seung-Jin;Lim, Young-Cheol;Yu, Chan
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.59-70
    • /
    • 2010
  • A long-term field demonstration experiment on selected stabilization methods to reduce the heavy metal mobility in farmland soil contaminated by heavy metals was conducted. The field demonstration experiment was established on the contaminated farmland with wooden plates (thickness = 1 cm), of which the dimension were width = 200 cm, Length = 200 cm, height = 80 cm, filled with treated soil, which was mixed with lime stone and steel refining slag except on control plot. Soil samples in the plots were collected and analyzed during the experiment period (6 months) after the installation of the plots. The field demonstration experiment results showed that the application lime stone at the ratio of 5% was effective for immobilizing heavy metal components in contaminated farmland soil.

Concrete plug cutting using abrasive waterjet in the disposal research tunnel (연마재 워터젯을 활용한 처분터널 내 콘크리트 플러그 절삭)

  • Cha, Yohan;Kim, Geon Young;Hong, Eun-Soo;Jun, Hyung-Woo;Lee, Hang-Lo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.153-170
    • /
    • 2022
  • Waterjet has been comprehensively used in urban areas owing to a suitable technique for cutting concrete and rock, and low noise and vibration. Recently, the abrasive waterjet technique has been adopted and applied by the Korea Atomic Energy Research Institute to demolish concrete plugging without disturbing and damaging In-situ Demonstration of Engineered Barrier System in the disposal research tunnel. In this study, the use of abrasive waterjet in the tunnel was evaluated for practical applicability and the existing cutting model was compared with the experimental results. As a variable for waterjet cutting, multi-cutting, water flow rate, abrasive flow rate, and standoff distance were selected for the diversity of analysis. As regarding the practical application, the waterjet facilitated path selection for cutting the concrete plugging and prevented additional disturbances in the periphery. The pump's noise at idling was 64.9 dB which is satisfied with the noise regulatory standard, but it exceeded the standard at ejection to air and target concrete because the experiment was performed in the tunnel space. The experimental result showed that the error between the predicted and measured cutting volume was 12~13% for the first cut and 16% for second cut. The standoff distance had a significant influence on the cutting depth and width, and the error tended to decrease with decrement of standoff distance.

Elastic Modulus and Layer Coefficient of Permeable Block Pavements Based on Plate Load Tests (평판재하시험을 통한 투수 블록포장의 탄성계수 및 상대강도계수 산정)

  • Choi, Yong-Jin;Oh, Jeong-Ho;Han, Shin-In;Ahn, Jaehun;Shin, Hyun-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.75-80
    • /
    • 2017
  • Permeable block pavement systems are widely used to relieve the flood and enhance water circulation. However, domestic design method has not yet been established well. Although AASHTO 93 flexible pavement design method is applied as a structural design method outside the country, there is a lack of information on layer coefficient of the permeable pavement materials, which makes it difficult to apply the design to various materials. Therefore, in this study, a method of calculating the layer coefficient of permeable block pavement materials by plate load test was presented and the layer coefficient of a permeable block pavement in a testbed was evaluated. Overall, calculated layer coefficient of open graded aggregate and permeable block pavement surface layer were similar to those of the conventional values. The presented method may be used to evaluate layer coefficients of permeable block pavements for design.

Real-Time Construction Resource Monitoring using RFID/USN Inter-working System (RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템)

  • Ryu, Jeoung-Pil;Kim, Hyoung-Kwan;Kim, Chang-Yoon;Kim, Chang-Wan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.90-94
    • /
    • 2007
  • Location tracking automation of resources in construction industry is one of the most important procedures to improve construction project performance and reduce the period of construction. Recently, location tracking technologies have proven to be effective in tracking construction materials and equipment in real time through the instrumentality of RFID (Radio Frequency Identification). By using wireless communication and inter-working system between RFID and USN, it is possible that construction engineers receive the location information of construction resources without additional efforts that move the RFID reader to read tags periodically. In the inter-working system, RFID reader delivers the acquired materials information to sensor node which is connected by serial interface. Then sensor node transmits the received data to the data aggregation terminal that is a sink node. The data aggregation terminal can transmit collected data to construction manager who is out of construction site using infrastructure such as CDMA(Code Division Multiple Access) network. The combination model of the two system and field test scenarios are presented in this paper.

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

Fresh Water Injection Test to Mitigate Seawater Intrusion and Geophysical Monitoring in Coastal Area (해수침투 저감을 위한 담수주입시험 및 지구물리 모니터링)

  • Park, Kwon-Gyu;Shin, Je-Hyun;Hwang, Se-Ho;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.353-360
    • /
    • 2007
  • We practiced fresh water injection test to identify its applibility as a method of seawater intrusion mitigation technique, and monitored the change of borehole fluid conductivity and the behavior of injected fresh water using borehole multichannel electrical conductivity monitoring and well-logging, and DC resistivity and SP monitoring at the surface. Well-logging and multichannel EC monitoring showed the decrease of fluid conductivity due to fresh water injection. We note that such an injection effect lasts more than several month which means the applibility of fresh water injection as a seawater intrusion control technique. Although SP monitoring did not show meaningful results because of weather condition during monitoring and the defects of electrodes due to long operation time, DC resistivity monitoring showed its effectiveness and applicability as a monitoring and assessment techniques of injection test by means of imaging the behavior and the front of fresh water body in terms of the increase of resistivity with reasonable resolution. In conclusion, we note that geophysical techniques can be an effective method of monitoring and evaluation of fresh water injection test, and expect that fresh water injection may be an practical method for the mitigation of seawater intrusion when applied with optimal design of injection well distribution and injection rate based on geophysical evaluation.

Study on Verification Evaluation of Wireless Network Introduction for Waterworks Supervisory and Control (수도사업장 감시제어를 위한 무선통신망 도입 신뢰성검증 연구)

  • Lee, An-Kyu;Park, Eun-Chul;Lee, Dong-Hoon;Hong, Sung-Taek;Kim, Nam
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.6
    • /
    • pp.195-200
    • /
    • 2009
  • In this paper, we verified the reliability through local examination by introducing a wired network that is operated at the local waterworks to wireless LAN based Wi-Fi network. The adopted wireless network compared to the existing wired network through saving cost and reducing breakdown points have been proven to be effective qualitatively and quantitatively. This study proved that wireless networks could be introduced for the advancement of operations management of existing metropolitan water supply and the local waterworks that are operating currently.

  • PDF

A Study on the Performance Verification for constructing the Full Digital Substation (Full 디지털변전소 구축을 위한 성능 검증에 관한 연구)

  • Lee, N.H;Han, J.Y;Lee, Y.J;Kim, S.K;Choi, J.K;Jang, B.T;An, Y.H
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.555-556
    • /
    • 2015
  • 디지털변전소의 정보를 최적화하여 변전소 Self-Healing, 자동고장복구 등 다양한 차세대 응용시스템을 개발하기 위해서는 변전소의 모든 설비를 네트워크로 연결하여 디지털화하는 Process 버스기반 디지털변전시스템은 필수적으로 필요하며, 이를 통해 변전소를 구축하고 엔지니어링 하는 과정전반이 컴퓨터 프로그램에 의해 쉽고 간편한 작업이 가능하게 되어 공간활용을 극대화할 수 있고 건설 및 유지보수 비용을 큰 폭으로 감소시킬 수 있다. 본 논문은 이러한 디지털변전소의 시대적 변화에 부합하여 국내에서 개발된 Process 버스 기반의 IED와 MU에 대하여 현장 적용을 위한 성능검증 방안을 제시하고, 국내 최초로 Process 버스 기반 디지털변전시스템 실증시험장을 제주 성산변전소에 구축하는 과정에서 수행한 검증결과를 설명하고자 한다.

  • PDF