• Title/Summary/Keyword: 현성확산계수

Search Result 21, Processing Time 0.029 seconds

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Quantitative, qualitative Evaluation of Diffusion-Weighted MRI using Optimal b-value(s/mm2) for Female Pelvis (여성골반에 대한 최적의 b-value(s/mm2)를 이용한 확산강조 자기공명영상의 정량적, 성적 평가)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.361-368
    • /
    • 2013
  • The purpose of this study is to know the clinical usefulness of optimal b-values by quantitative, qualitative evaluation of DW-MRI for lesions of benignity and malignity of female pelvis. The b-values used in DWI were 600, 800, 1000, 1200, 1400($s/mm^2$). Mean SNR and CNR of myoma in b-value 800 were the highest result as $84.6{\pm}4.57$(p=0.024) and $50.13{\pm}5.47$(p=0.028), Mean SNR and CNR of cervical cancer were the highest result as $12.0{\pm}2.04$(p=0.047) and $10.6{\pm}1.24$(p=0.001), Mean ADC value in myoma and cervical cancer in b-value 800 were $1.19{\times}10^{-3}mm^2/s$(p=0.008), $0.96{\times}10^{-3}mm^2/s$(p=0.027). As a qualitative analysis, the delineation and conspicuity were the highest result as $4.02{\pm}0.18$(p=0.028), $4.39{\pm}0.25$(p=0.015) on b-value 800. DW-MRI is an important method, and the optimal b values is 800 $s/mm^2$ for differentiation between benign and malignant lesions of female pelvis.

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Diffusion-Weighted Imaging Findings in Patients with Status Epilepticus: Report of Two Cases (경련 중첩증 환자의 확산 강조 영상 소견: 2 증례 보고)

  • Sung Il Jung;Bae Ju Kweon;Keon Ha Kim;Moon Hee Han;Kee-Hyun Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.56-60
    • /
    • 2003
  • We present MR diffusion-weighted imaging (DWI) findings of status epilepticus in two patients. DWI showed a focal or diffuse hyperintensity with decreased apparent diffusion coefficient (ADC) value, indicating cytotoxic edema in th e cerebral hemispheric cortices. The hyperintensities were located in the bilateral temporoparietooccipital areas and insular cortex in one patient, and unilaterally in the temporal lobe in the other patient.

  • PDF

A Change of Apparent Diffusion Coefficient in Diffusion Weighted Imaging Applied with Rectangular FOV Technique (확산강조영상 검사 시 rectangular FOV 적용에 따른 ADC 값의 변화)

  • Na, Sa-Ra;Choi, Kwan-Woo;Koo, No-Hyun;Yoo, Beong-Gyu;Son, Soon-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.545-550
    • /
    • 2016
  • The purpose of this study is to improve the mapping between functional image and conventional image by using rectangular FOV technique. Diffusion weighted imaging which is widely used for stroke was acquired by reducing the FOV and compared each Apparent Diffusion Coefficient(ADC). As a result, there is no significant difference of each ADC value in one-way-anova analysis and post-hoc analysis. Thus, Mismatching problem may be improved by matching the FOV with rectangular FOV technique because there is no difference in ADC values.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging (역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측)

  • Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer (유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석)

  • Lee, Jae-Heun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.755-762
    • /
    • 2018
  • The purpose of this study was to compare the FA(faractional anisotropy) and ADC(apparent diffusion coefficient) values, which were derived from diffusion tensor imaging in breast cancer patients. The diffusion gradient used in this study was derived from quantitative diffusion indices using 20 directions(b-value, 0 and $1,000s/mm^2$). Quantitative analysis was analyzed using Pearson's correction and qualitative analysis using for correction coefficients. As a result, $FA_{min}$, $FA_{mean}$ and $FA_{max}$ were $0.098{\pm}0.065$, $0.302{\pm}0.142$ and $0.634{\pm}0.236$, respectively(p > 0.05). The $ADC_{min}$, $ADC_{mean}$ and $ADC_{max}$ were $0.741{\pm}0.403$, $1.095{\pm}0.394$ and $1.530{\pm}0.447$, respectively(p > 0.05). The $FA_{min}$, $FA_{mean}$, and $FA_{max}$ mean values were $0.132{\pm}0.050$, $0.418{\pm}0.094$, and $0.770{\pm}0.164$ for Category 6 and Kinetic Curve Pattern III, respectively. $ADC_{min}$, $ADC_{mean}$, and $ADC_{max}$ were $0.753{\pm}0.189$, $1.120{\pm}0.236$, and $1.615{\pm}0.372$, respectively. Quantitative analysis showed negative correlation between $ADC_{mean}-FA_{mean}$ and $ADC_{max}-FA_{max}$(p = 0.001, 0.003). The qalitative analysis showed ADC 0.628(p = 0.001), FA 0.620(p = 0.001) in the internal evaluations, ADC 0.677(p = 0.001), FA 0.695(p = 0.001) in external evaluations. In conclusion, based on the morphological examination, time to signal intensity graph is the form of wash-out(pattern III) in the dynamic contrast enhance examination, As a result, the $ADC_{mean}$ $1.120{\pm}0.236$ and $FA_{mean}$ values were $0.032{\pm}0.142$ with a negative correlation (Y=1.44-1.12X). Therefore, If we understand the shape of time to signal intensity graph and the relationship between ADC and FA, It will be a criterion for distinguishing malignant diseases in breast cancer.

Diffusion-weighted MR Imaging of Hypoxic-Ischemic Encephalopathy (저산소성-허혈성 뇌증의 확산강조영상 소견)

  • Choi, Hye-Young;Choi, Dae-Seob;Ryoo, Jae-Wook;Cho, Jae-Min;Ko, Eun-Sook;Shin, Tae-Beom;Na, Jae-Beom;Choi, Nak-Cheon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.49-54
    • /
    • 2008
  • Purpose : The purpose of this study was to determine the characteristics of hypoxic-ischemic encephalopathy (HIE) on diffusion-weighted imaging (DWI) and the role of DWI for the diagnosis of HIE. Materials and Methods : Six patients with HIE underwent MRI including DWI. MR examinations were performed within 4 - 32 days (mean, 11.8 days) after hypoxic brain insult. We assessed the distribution of the lesions and compared the DWI and T2, FLAIR images for the subjective conspicuity of the lesions. Results : In all patients, symmetrical hyperintense lesions were demonstrated in the bilateral basal ganglia on T2, FLAIR, and DWI. On ADC map image, the lesions were hypointense in four of six patients and isointense in other two patients. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in four of six patients and similar in other two patients. For the involvement of the cortex and subcortical white matter, in five of six patients, bilateral symmetric hyperintense lesions were seen on T2, FLAIR, and DWI. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in three of them and similar in other two patients. On ADC map image, the lesions showed hypointensity in three of five patients and isointensity in other two patients. For the involvement of the deep cerebral white matter, T2, FLAIR, and DWI showed bilateral symmetric hyperintense lesions in four of six patients. Among them, Lesion conspicuity on DWI was higher than on T2 and FLAIR images in only one patient. Conclusion : HIE is characterized by symmetrical hyperintense lesions in the bilateral basal ganglia, cerebral cortex, and white matter on DWI and the lesions are more conspicuously demonstrated on DWI than on T2 and FLAIR images.

  • PDF