• Title/Summary/Keyword: 헬멧

Search Result 119, Processing Time 0.021 seconds

Gesture Recognition based on Mixture-of-Experts for Wearable User Interface of Immersive Virtual Reality (몰입형 가상현실의 착용식 사용자 인터페이스를 위한 Mixture-of-Experts 기반 제스처 인식)

  • Yoon, Jong-Won;Min, Jun-Ki;Cho, Sung-Bae
    • Journal of the HCI Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • As virtual realty has become an issue of providing immersive services, in the area of virtual realty, it has been actively investigated to develop user interfaces for immersive interaction. In this paper, we propose a gesture recognition based immersive user interface by using an IR LED embedded helmet and data gloves in order to reflect the user's movements to the virtual reality environments effectively. The system recognizes the user's head movements by using the IR LED embedded helmet and IR signal transmitter, and the hand gestures with the data gathered from data gloves. In case of hand gestures recognition, it is difficult to recognize accurately with the general recognition model because there are various hand gestures since human hands consist of many articulations and users have different hand sizes and hand movements. In this paper, we applied the Mixture-of-Experts based gesture recognition for various hand gestures of multiple users accurately. The movement of the user's head is used to change the perspection in the virtual environment matching to the movement in the real world, and the gesture of the user's hand can be used as inputs in the virtual environment. A head mounted display (HMD) can be used with the proposed system to make the user absorbed in the virtual environment. In order to evaluate the usefulness of the proposed interface, we developed an interface for the virtual orchestra environment. The experiment verified that the user can use the system easily and intuituvely with being entertained.

  • PDF

A Network Analysis of Ballistic Helmet Technology Keyword (방탄헬멧 기술분야 키워드에 대한 네트워크 분석)

  • Kang, Jinwoo;Park, Jaewoo;Kim, Jihoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.311-316
    • /
    • 2017
  • The network analysis method has emerged as a new methodology for various disciplines, due to its ability to provide a representative knowledge network of references, co-authors and keywords. Bulletproof technology is an interdisciplinary field involving various disciplines, such as material mechanics, structural mechanics, and ballistics, so it is essential to keep up with the recent trends in technological research. In this research, the recent R&D trends in the field of bulletproof materials were analyzed using keyword based network analysis. From the results, the core keywords were identified as 'Composite', 'Model' and 'Head' using the scholar search engine, google scholar. The centrality analysis for the core keywords showed that bulletproof technology has developed in 3 different areas, viz. material, structure and effects. To the best of our knowledge, this is the first application of (network analysis?) to bulletproof technology. Moreover, we are also convinced that the results of this study will be useful for defense technology planning and determining the direction of R&D in the field of bulletproof technology.

Development and Application of Science Career Education Materials Using TV Programs in Junior High School (TV 프로그램을 활용한 중학교 과학 진로교육 자료 개발 및 적용)

  • Yoon, Hye-Gyoung;Kim, Hyoung-Seok;Jung, Hyung-Si;Kim, Joung-Youn;Kim, Myoung-Soon
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.4
    • /
    • pp.518-526
    • /
    • 2006
  • Science career education is for every student as well as for students who want to become scientists. In this study, we developed and applied science career education materials using TV programs which showed successful application of science in industry and business. The effects of the programs were surveyed mainly by questionnaire on 'Science Career Orientation', which have four categories.Video materials using TV programs were effective in changing science career orientation (p<0.05) of junior high school students, but only when the teacher added some cognitive explanation on the scientific concept involved. Providing only video materials were not enough to make meaningful change on science career orientation. The results implied science career education should be linked with science teaching and learning. It also showed the possibility and the way of using informal education like TV program in science career education.

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling (3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램)

  • Perez, Marlon;Hernandez, Daniel;Michel, Eric;Cho, Min Hyoung;Lee, Soo Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.107-119
    • /
    • 2014
  • Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visual comparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a $C^{{+}{+}}$- and MATLAB-based software tool called Phased Array Coil Evaluator (PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results, and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil position coordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. After making the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform has been made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulation and experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiled gradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTD simulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivities element-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodic maintenance of phased array coils in a more accurate and consistent manner.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Injuries and Prevention methods Associated with In-Line Skate (인라인 스케이트시 발생한 손상 밑 예방)

  • Lim Hong Chul;Chun Seung Joo;Rho Young Jin;Hwang Jin Ho;Park Chan Eung;Kim Tae Un
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.163-167
    • /
    • 2003
  • Purpose: The purpose of this study is to describe causes and injury mechanisms during inline skating and to find preventive measures .Materials and Methods: We have carefully selected 57 patients who have been treated in our hospital and nearby hospital. There are 37 males and 20 females, and mean age is 9 years 9 months (range,6-40 years old) . We have meticulously investigated their injured sites, their favorite location for inline skating , their use of protective means while they were on the wheels and their injury mechanisms . Results: Injury consisted of 50 fractures,1 meniscal tear,2 medial collateral ligament rupture and 4 contusion or sprain. Fracture sites varied as follows : 33(66$\%$) cases in distal radius and ulna,5(10$\%$) in elbow. 3(6$\%$) in diaphysis of humerus, etc Location at the time of injury varied as follows : 22 cases(39$\%$) in their apartment complex, 19 cases in (33$\%$) narrow streets, and 16 cases(28$\%$) in parks Only five patients admitted that any means of protection were used.2 cases only had knee pad on , 1 case put on elbow pad in addition, and 2 cases put on wrist guard as well. However none of the patients had helmet on Conclusion: We would strongly like to stress the importance of using sufficient protections and of choosing area where it is safe to ride, in order to reduce the risk of accidents. In addition, continuous and effective prior education from inline skate circles may be in order before riding the inline skate.

  • PDF

Fractionated Stereotactic Radiation Therapy for Intracranial Benign Tumor : Preliminary Results of Clinical Application (양성 뇌종양의 분할정위 방사선치료 : 임상적 응용의 예비적 결과)

  • Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Choi Dong Rak;Nam Jong Hyun;Lee Jung Il;Park Kwan;Nam Do-Hyun;Kim Moon Kyung
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.185-194
    • /
    • 1998
  • Purpose : With the development of stereotactic immobilization systems capable of reliable serial repositioning, fractionated stereotactic radiation therapy (FSRT) offers the Potential for an improved treatment outcome by excellent dose delivery, and dose distribution characteristics with the favorable radiobiological properties of fractionated irradiation. We describe our initial experience using FSRT for the treatment of intracranial benign tumor. Materials and Methods : Between August 1995 and December 1996. 15 patients(7 males and 8 females aged 6-70 years) were treated with FSRT. The patients had the following diagnosis pituitary adenoma(10) including one patient who previously had received radiotherapy, craniopharyngioma (2), acoustic neurinoma (1), meningioma (2). Using the Gill-Thomas-Cosman relocatable head frame and multiple non-coplanar therapy, the daily dose of 2Gy was irradiated at 90% to 100% isodose surface of the isocenter The collimator sizes ranged from 26mm to 70mm. Results : In all patients except one follow-up lost, disease was well-controlled. Acute complication was negligible and no patient experienced cranial nerve neuropathies and radiation necrosis. In overall patient setup with scalp measurements, reproducibility was found to have mean of $1.1{\pm}0.6mm$ from the baseline reading. Conclusion : Relocatable stereotactic system for FSRT is highly reproducible and comfortable. Although the follow-up period was relatively short. FSRT is considered to be a safe and effective radiation technique as the treatment of intracranial tumor. But the fractionation schedule(fraction size, overall treatment time and total dose) still remains to be solved by further clinical trials.

  • PDF

4D Printing Materials for Soft Robots (소프트 로봇용 4D 프린팅 소재)

  • Sunhee Lee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.6
    • /
    • pp.667-685
    • /
    • 2022
  • This paper aims to investigate 4D printing materials for soft robots. 4D printing is a targeted evolution of the 3D printed structure in shape, property, and functionality. It is capable of self-assembly, multi-functionality, and self-repair. In addition, it is time-dependent, printer-independent, and predictable. The shape-shifting behaviors considered in 4D printing include folding, bending, twisting, linear or nonlinear expansion/contraction, surface curling, and generating surface topographical features. The shapes can shift from 1D to 1D, 1D to 2D, 2D to 2D, 1D to 3D, 2D to 3D, and 3D to 3D. In the 4D printing auxetic structure, the kinetiX is a cellular-based material design composed of rigid plates and elastic hinges. In pneumatic auxetics based on the kirigami structure, an inverse optimization method for designing and fabricating morphs three-dimensional shapes out of patterns laid out flat. When 4D printing material is molded into a deformable 3D structure, it can be applied to the exoskeleton material of soft robots such as upper and lower limbs, fingers, hands, toes, and feet. Research on 4D printing materials for soft robots is essential in developing smart clothing for healthcare in the textile and fashion industry.