• Title/Summary/Keyword: 허용 기준

Search Result 1,694, Processing Time 0.026 seconds

Groundwater control measures for deep urban tunnels (도심지 대심도 터널의 지하수 변동 영향 제어 방안)

  • Jeong, Jae-Ho;Kim, Kang-Hyun;Song, Myung-Kyu;Shin, Jong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.403-421
    • /
    • 2021
  • Most of the urban tunnels in Korea, which are represented by the 1st to 3rd subways, use the drainage tunnel by NATM. Recently, when a construction project that actively utilizes large-scale urban space is promoted, negative effects that do not conform to the existing empirical rules of urban tunnels may occur. In particular, there is a high possibility that groundwater fluctuations and hydrodynamic behavior will occur owing to the practice of tunnel technology in Korea, which has mainly applied the drainage tunnel. In order to solve the problem of the drainage tunnel, attempts are being made to control groundwater fluctuations. For this, the establishment of tunnel groundwater management standard concept and the analysis of the tunnel hydraulic behavior were performed. To prevent the problem of groundwater fluctuations caused by the construction of large-scale tunnels in urban areas, it was suggested that the conceptual transformation of the empirical technical practice, which is applied only in the underground safety impact assessment stage, to the direction of controlling the inflow in the tunnel, is required. And the relationship between the groundwater level and the inflow of the tunnel required for setting the allowable inflow when planning the tunnel was derived. The introduction of a tunnel groundwater management concept is expected to help solve problems such as groundwater fluctuations, ground settlement, depletion of groundwater resources, and decline of maintenance performance in various urban deep tunnel construction projects to be promoted in the future.

Analysis of Rana coreana Behavior According to the Slope Angle Degree of Escape Ramp (콘크리트 수로 탈출로 경사각에 따른 한국산개구리 행동 분석)

  • Lee, Taeho;Kim, Jungkwon;Seo, Jihye;Jang, Moonjeong;Choi, Taeyoung;Chang, Minho
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2022
  • The purpose of this study is to propose the angle-limit of the escape ramp by analyzing the frog behavior characteristics according to the inclination angle of the waterway escape ramp installed in the concrete U-bench plume pipe channel. Forthe experiment, an escape test device was manufactured with the same shape and number of materials applied in the field. And Rana coreana living in paddy wetlands were sel selected. The main behaviors of frogs on the slope were 'jumping', 'crawling' and 'slipping', and afterrecording the behavioralresults according to the inclination angle, statistical analysis was conducted using the chi-square test method. As a result of the analysis, there was no statistically significant difference between 30° and 40°. This result is an evidence for expanding the standard of inclination angle 30° suggested in the 'Guidelines for Installation and Management of Ecological Pathways' to a maximum of 40°. However, further research is required in that the escape ramp targets not only Korean frogs but also various small wild animals. However, considering that various wild animals are affected by artificial canals, additional studies using various target wild animals are needed.

Application and Adequacy Evaluation of Mobile Sewage Treatment Facilities for Concrete Wastewater Treatment Generated during Construction (공사 중 발생되는 콘크리트 폐수처리를 위한 이동식 오수처리 시설의 적용 및 적정성 평가)

  • Wooseok Jeong;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.25 no.2
    • /
    • pp.91-98
    • /
    • 2023
  • Some concrete wastewater generated during construction is in the form of non-point pollution sources that workers, managers, and users are unaware of, and it is not easy to manage as it flows through sewage pipes. Due to these characteristics, construction sludge is inflow into rivers and sewage pipes in the form of non-point pollution sources in an unmanaged state. This study applied the D.W.S method to the concrete retaining wall removal method installed on the road, and the resulting concrete wastewater was physically and chemically treated through a mobile sewage treatment facility, and it was examined whether it met the removal efficiency and wastewater discharge acceptance standards. Accordingly, it is intended to meet the standards for effluent concentration of wastewater during construction by removing 73.5% of BOD and 89.1% of SS through physical and chemical treatment through portable sewage treatment facilities during construction. In addition, we would like to review the adequacy and economic analysis of calculating environmental conservation costs for physicochemical treatment through portable sewage treatment facilities and sewage treatment generated during construction.

Der Begriff der Heilkundeausübung nach deutschem Medizinrecht (독일법상 의료행위 개념)

  • Seok-Bae Lee
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.3-31
    • /
    • 2023
  • Der Begriff der Heilkundeausübung ist im positiven Recht in Korea nirgends festgelegt. Der wurde jedoch indirekt durch die Auslegung der Heilkundeausübung ohne Erlaubnis gemäß § 27 Abs. 1 des "Medizingesetzes" geregelt. In der Vergangenheit beschränkte der kOGH(the Supreme Court of Korea) die Heilkundeausübung auf die "Behandlung von Krankheiten und stellte fest, dass "medizinische und technische Maßnahmen, die keine pathologischen Symptome oder Funktionsdefizite im Körper voraussetzen, nicht zur Heilkundeausübung gehören." Danach änderte der kOGH seine Rechtsprechung auf "Vorbeugung oder Behandlung von Krankheiten durch Durchführung ärztlicher Untersuchungen, Optometrie, Verschreibung, Medikation oder chirurgischer Eingriffe auf der Grundlage von Erfahrung und Fähigkeiten, die auf medizinischem Fachwissen basieren, und anderer Gesundheitsfürsorge, definiert "medizinische Maßnahmen" als "eine Handlung, die eine gesundheitliche Gefahr darstellen kann, sofern diese nicht von einem Mediziner durchgeführt wird". Der Begriff der Heilkundeausübung in der Rechtsprechung ist einerseits zu abstrakt und kann eine Leerformel sein, andererseits kann seine Einschränkung eine Gefahr für die öffentliche Gesundheit erbringen. Daher besteht Bedarf an einem Kriterium, das dar derzeitige Begriff der Heilkundeausübung entsprechend dem gesetzgeberischen Ziel reduzieren kann, das Risiko für das Leben, den Körper oder die öffentliche Gesundheit von Menschen zu verhindern, das durch die Durchführung medizinischer Arbeiten durch nichtmedizinisches Personal entstehen kann. Um ein Kriterium vorzustellen, das das aktuelle Konzept der Heilkundeausübung reduzieren kann, werden in diesem Artikel das positive Recht, Theorien und Rechtsprechung zum Begriff der Heilkundeausübung in Deutschland untersucht und nach einer Alternative gesucht.

Monitoring of Quality Characteristics and Harmful Substances in Commercial Handmade Soap (유통 수제비누의 품질특성 및 유해물질 모니터링)

  • Yeon Ji Kim;In Sook Lee;Su Ae Kim;Koth Bong Woo Ri Kim;Ho Cheol Yun;Pyeung Tae Gu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.3
    • /
    • pp.213-223
    • /
    • 2023
  • A total of 81 handmade soaps on sale on the market were collected from January to November 2022. To compare quality characteristics, all ingredients were referred to, and the pH, dry reduction, heavy metals (lead, arsenic, cadmium, antimony, and mercury), and contents of free alkali were measured. All soaps had a slightly alkaline pH of 7.9 to 11.2, average drying loss was 17.6%, and free alkali was hardly detected. The average values of all heavy metals were 0.104 ㎍/g for lead, 0.035 ㎍/g for arsenic, 0.002 ㎍/g for cadmium, 0.048 ㎍/g for antimony, and 0.0003 ㎍/g for mercury. The results of handmade soap were below the recommended in regulations on safety standards for cosmetics of Ministry of Food and Drug Safety.

A Study on the Removal of Fluorine from Leachate of Reclaimed Mine Waste Dump Site Using Alum Coagulation (알럼 응집을 이용한 광산폐기물 적치장 침출수 내 불소 제거 연구)

  • Sang-Woo Lee;Woo-Chun Lee;Seong Hee Kim;Sang Heon Jeong;Bo Young Lee;Sang-Hwan Lee;Soon-Oh Kim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.1
    • /
    • pp.19-32
    • /
    • 2023
  • This study was conducted to remove fluorine (F) (initial concentration of 9.5 mg/L) from leachate of reclaimed mine waste dump site via different methods: (1) co-precipitation using Ca-based materials; (2) adsorption using activated carbon and fly ash; and (3) coagulation and sedimentation using alum. The F removal efficiencies of each case were estimated as 65.6% (Ca co-precipitation), 27.9% (adsorption of activated carbon), 71.5% (adsorption of fly ash), and 96.6% (alum coagulation and sedimentation). In addition, the applicability of the continuous treatment process using alum coagulation was evaluated by lab-scale experiments using simulated mine drainage containing F of lower (6.4 mg/L) and higher (15.7 mg/L) concentrations, and it was confirmed that the treatment of both cases met the domestic standard (below 3 mg/L) for discharged water in clean areas. Furthermore, the results of bench-scale field tests indicated that the water quality standard of discharged water could be satisfied with the proper operation and management of the process.

Calculation of Crack Width of the Top Flange of PSC Box Girder Bridge Considering Restraint Drying Shrinkage (구속 건조수축을 고려한 PSC BOX 거더교 상부플랜지 균열폭 산정)

  • Young-Ho Ku;Sang-Mook Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2023
  • The PSCB girder bridge is a closed cross-section in which the top and bottom flanges and the web are integrated, and the structural characteristics are generally different from the bridges in which the girder and the floor plate are separated, so a maintenance plan that reflects the characteristics of the PSCB girder bridge is required. As a result of analyzing damage types by collecting detailed safety diagnosis reports of highway PSCB girder bridges, most of the deterioration and damage occurring during use is concentrated on the top flange. In particular, cracks in the bridge direction on the underside of the top flange occurred in about 70 % of the PSCB girder bridges to be analyzed, and these cracks were judged to be caused by indirect loads such as heat of hydration and drying shrinkage rather than structural cracks caused by external loads. In order to improve durability and reduce maintenance costs of PSCB girder bridges in use, it is necessary to control restraint drying shrinkage cracks from the design stage. Therefore, in this paper, the cracks caused by drying shrinkage under restraint, which is the main cause of cracks under the flanges of the top part of the PSCB girder bridge, were directly calculated using the Gilbert Model, and the influencing factors such as the amount of reinforcing bars, diameter and spacing of reinforcing bars were analyzed. As a result of the analysis, it was found that the crack width caused by restraint drying shrinkage exceeded the allowable crack width of 0.2 mm for reinforcing bars with a reinforcing bar ratio of 0.01 or less based on the H16 reinforcing bar and a reinforcing bar with a diameter greater than H19 based on the reinforcing bar ratio of 0.01. Finally, based on the results of the crack width review, a method for controlling the crack width of the top flange of the PSCB girder bridge was proposed.

A Study on the Slip Behavior of Coated High Tension Bolted Joints (도장처리한 고장력볼트 연결부의 미끄러짐 특성에 관한 연구)

  • Kyung, Kab Soo;Lee, Seung Yong;Kim, Ki Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.691-697
    • /
    • 2008
  • Coating the high tension bolted frictional joint has been generally allowed for anti-corrosion purpose. However in case of painting on paying surface of the high tension bolt, the influence on a slip strength of the joint depending on precision of painting has remained controversial. The study thus was intended to identify the slip behavior on high tension bolted frictional joint when applying ceramic painting, which has been currently developed. A slip test was conducted on a high tension bolted frictional joint specimen on which ceramic painting has been applied and a slip load and slip coefficient were measured. Based on result, the safety and usability of ceramic painting-applied high tension bolted frictional joint was evaluated. As a result, a difference to some extent by specimen in terms of load-displacement when a slip occurred was observed but an average slip coefficient appeared to have exceeded 0.4, which is the design frictional coefficient set forth in the specification. To secure the safety and usability of ceramic painting-applied high tension bolted frictional joint, it's necessary to establish the standard for painting as well as to revise the relevant specification.

The Comparative Analysis of Reservoir Capacity of Chungju Dam based on Multi Dimensional Spatial Information (다차원 공간정보 기반의 충주댐 저수용량 비교분석)

  • Lee, Geun Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.5D
    • /
    • pp.533-540
    • /
    • 2010
  • Dam is very important facility in water supply and flood control. Therefore study needs to analyze reservoir capacity accurately to manage Dam efficiently. This study compared time series reservoir capacity using multi-dimensional spatial information to Chungju Dam reservoir and major conclusions are as follows. First, LiDAR and multi beam echo sounder survey were carried out in land zone and water zone of Dam reservoir area. And calibration process was performed to enhance the accuracy of survey data and it could be constructed that multi dimensional spatial information which was clearly satisfied with the standard of tolerance error by validation with ground control points. Reservoir capacity by water level was calculated using triangle irregular network from detailed topographic data that was constructed by linked with airborne LiDAR and multi beam echo sounder data, and curve equation of reservoir capacity was developed through regression analysis in 2008. In the comparison of the reservoir capacity of 2008 with those of 1986 and 1996, the higher water level goes, total reservoir capacity of 2008 showed decrease because of the increase of sediment in reservoir. Also, erosion and sediment area could be analyzed through calculating the reservoir capacity by the range of water level. Especially the range of water level as 130.0~135.0 which is the upper part of average water level, showed the highest erosion characteristics during 1986~2008 and 1996~2008 and it is considered that the erosion of reservoir slant by heavy rainfall is major reason.

Development of the Large-Capacity Mooring Fittings according to MEG4(Mooring Equipment Guideline 4) (MEG4(Mooring Equipment Guideline 4) 적용에 따른 대용량 무어링 피팅 개발)

  • Myung-Su Yi;Kwang-Cheol Seo;Joo-Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.950-957
    • /
    • 2023
  • For safe mooring and towing between the ship and port, the equipment must be designed in accordance with the relevant international regulations. However, some small shipyards and engineering companies often do not fully comprehend the core contents. Therefore, the international regulations regarding towing and mooring equipment are reviewed and the bollard and chock are newly developed based on the Mooring Equipment Guideline 4 (MEG4) standards. A bollard is a mooring equipment used to fix a mooring rope to the hull. It has two columns and is mostly used in a figure eight pattern knots under the mooring condition. The chock, which is used to change the mooring rope direction coming into the ship from outside, is manufactured using a casting with curvature. The two mooring equipment are widely used in the stern, bow, and mid-side. Owing to the increase in the size of container vessels and LNG ships, the mooring rope load has increased and the safe working load of the mooring equipment must be revised. This study summarizes and examines the results of the allowable stress method obtained using finite element analysis modelling. To consider the mesh size effect, a reasonable criteria was suggested by referring the existing class guidance. Additionally, the safe working load was verified through nonlinear collapse analysis, and the elastic region against load increments was confirmed. Furthermore, the proposed evaluation method can be used to develop similar equipment in the near future.