• Title/Summary/Keyword: 허용한계

Search Result 541, Processing Time 0.026 seconds

Developments of monitoring system to measure sound absorbing coefficient and structural stability of sound absorbing panel on the concrete track in the urban train tunnel (도시철도 터널 내부 콘크리트 도상 국소공명흡음판의 흡음계수 및 구조안정성 평가를 위한 계측시스템 개발)

  • Oh, Soon-Taek;Lee, Dong-Jun;Lee, Dong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • In this study, a test-bed system simulated a tunnel and concrete track is tested on cite and invested an allowed limit of multi-layered sound absorbing panel for reducing noise reflected on the concrete track in train tunnel considering the criteria and limitation on the theoretical back ground. The studied results are an effective evaluating system of the sound absorbing coefficient influenced fluid effects depending on the vehicle speed in the urban train tunnel and measuring not only structural behaviors of maximum displacement and acceleration of the panel but also dynamic characteristics of damping ratio and natural frequency.

The Crack Analysis and Redesign of Horizontal Fin of F-5E/F's External Fuel Tank (F-5E/F 외부 연료탱크 수평 핀 균열 분석 및 재설계)

  • Kang, Chi-Hang;Yoon, Young-In;Jung, Dae-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.382-388
    • /
    • 2010
  • In this work the replacement material for magnesium alloy was investigated and an optimized design was suggested for the horizontal fin of a fighter's external fuel tank. For the replacement of magnesium alloy, Aluminum alloy, AL 2034-T351, was selected by considering material properties and its procurement. The strength and fracture toughness properties of AL 2034-T351 are stronger than those of magnesium alloy, but the specific weight of AL 2034-T351 is heavier than that of magnesium alloy by 65%. To meet the allowable limit of C.G. shift in the tank, the design of horizontal fin was optimized by reducing the original shape by 20% and resizing the maximum thickness to 7 mm. From the results of the static and dynamic stress analysis for improving the safety factor of the joint section and the joint hole, the radius of curvature in the aft joint section of the new fin was designed as 8.5mm.

Permissible Safety Limits in Local Cooling Focused on the Parts of Human Body (신체 부위별 냉각허용한계온도에 관한 연구)

  • Hwang, Kyoung-Sook;Choi, Jeong-Wha;Kim, Kyung-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.119-130
    • /
    • 2007
  • The objects of this study were to investigate responses and peculiarity during local cooling by parts of the human body and to show permissible safety limits without injurious to his health because of excessive cooling when he works hot environments. It were measured rectal temperature, skin temperature, heart rate, total body weight loss, local sweat in back and thigh, clothing microclimate and subjective sensation on 8 subjects and cooling parts were head, neck, chest, abdomen, back, waist, hip, upper arm, forearm, hand, thigh, calf and foot. According to above-mentioned the first experiment, we chose permissible safety limits by parts of the human body for one hour. In the second experiment, it was showed permissible safety limits by parts which examined their safety about health through 4 hours cooling test on 3 subjects. The results are as follows: 1. As a result of the first experiment, we chose permissible safety limits by parts, as follows, head $25^{\circ}C$, neck $20^{\circ}C$, chest $27^{\circ}C$, abdomen $25^{\circ}C$, back $20^{\circ}C$, waist $20^{\circ}C$, upper arm $20^{\circ}C$, forearm $20^{\circ}C$, hand $23^{\circ}C$, thigh $20^{\circ}C$, calf $20^{\circ}C$ and foot $23^{\circ}C$ in $37^{\circ}C$, 50%R.H. environment for 1 hour. 2. As a result of the second experiment, cooling on these safety limits temperatures except chest didn't have a bad effect on health. So it was proved that right permissible safety limits of chest was $28^{\circ}C$. From these results, it has been suggested that skin temperature didn't fall below permissible safety limits when human body was to be cool by parts.

Determination of Benzimidazole Residues in Livestock Products (축산식품 중 벤지미다졸계 구충제 잔류실태 조사)

  • Lee, Kyung-Jin;Kang, Young-Woon;Kang, Eung-Ui;Kim, Mi-Ran;Bahn, Kyeong-Nyeo;Jang, Young-Mi;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.515-520
    • /
    • 2010
  • This research investigated benzimidazole residues (albendazole, fenbendazole, flubendazole, thiabendazole, oxibendazole) in livestock products. A total of 270 samples of livestock products (beef, pork and chicken) were purchased from local markets in Korea. Ethyl acetate was used to extract analytes from the sample, after which ethyl acetate extracts were purified using a MCX cartridge. Analytes were detected using liquid chromatography-tandem mass spectrometry. The limit of detection was 0.01-0.04 ppb, the limit of quantification was 0.03-0.13 ppb, the linearity ($r^2$) was 0.9992-1.0000, and the recovery was 70-85%. Residues of benzimidazoles, except for fenbendazole in pork, were not found in any of the 270 livestock samples. Fenbendazole was detected in the range of 1.2 to 3.1 ppb in 12 samples of pork.

Limit Analysis of the Distance between DU and RU in 4G FDD Mobile Communication Systems (FDD 방식의 4G 이동통신 기지국에서 DU와 RU간 한계거리 분석)

  • Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.135-139
    • /
    • 2012
  • A majority of 4G Mobile communication manufacturers have launched separated-type base stations composed of DU (digital unit) and RU (ratio unit). DUs are usually installed in the central office, while RUs with antennas are installed on the top of building or pole. Therefore, the allowable distance between DU and RU is very important for cell planning. In this paper, we analyze the allowable distance between DU and RU induced by closed-loop MIMO (mulitple input multiple output) technology in 4G FDD (frequency division duplexing) mobile communication systems. In conclusion, the distance limit between DU and RU is dependent on the frequency of the wireless communication, and the allowable distance is about 11 km when assuming the operating frequency is 2 GHz.

The impact college students' sexual assault awareness has on the sexual assault experience :Mediating effects of the sexual violence allowance scale (대학생의 성폭력 인식도가 성폭력 피해경험에 미치는 영향 : 성폭력 허용도의 매개효과)

  • Kang, cha-sun;Jung, Min;Yoem, Soon-Joung;Park, Jeong-hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.551-560
    • /
    • 2016
  • The aim of this study was to verify the effect of the parameters in relation to college students' awareness of sexual assault and sexual violence experience. The subjects were 408 male and female college students attending four universities located in Jeju island. Sexual assault awareness measures, sexual violence experience scale, and the scale of sexual violence allowance scale were used in the questionnaires. First, correlation analysis showed a significant negative correlation between sexual violence awareness and sexual violence. Also, sexual violence awareness and sexual violence allowance scale showed a considerable negative correlation. This suggests that the higher the sexual assault awareness, the lower the sexual damage and sexual violence allowance scale. Second, after analyzing the division of the subject into research model and competition model to verify the mediation effect in relationship of the sexual violence awareness and sexual violence experience, it was clear that sexual awareness does not have a direct effect on the experience of sexual damage. It rather mediated the sexual violence allowance scale. Therefore, the research model, which is the full mediation model, was selected. In other words, sexual assault awareness appeared to fully mediate the relationship between sexual assault awareness and sexual assault experience. This means that sexual assault perception has an indirect influence through sexual assault allowance rather than a direct effect on the sexual assault experience. Thus, the more well established that sexual assault awareness is, the lower the sexual assault allowance scale. Finally, the lowered sexual assault allowance scale could reduce the sexual assault harm. To improve the sexual assault recognition, a systematic sexual violence prevention education should be conducted. Sexual assault prevention education would allow students in dating relationships to become mature in their human rights and maintain the proper emotional relationship and enable a reduction in the harm sexual assault as a result of giving them the consideration. Finally, this study had a limitation in selecting the subjects as the college students living in Jeju. Therefore, in order to compensate for this limitation, follow-up studies should be carried out on with a sample of generalized and various research subjects.

Development and Validation of a Simultaneous Analytical Method for 5 Residual Pesticides in Agricultural Products using GC-MS/MS (GC-MS/MS를 이용한 농산물 중 잔류농약 5종 동시시험법 개발 및 검증)

  • Park, Eun-Ji;Kim, Nam Young;Shim, Jae-Han;Lee, Jung Mi;Jung, Yong Hyun;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.228-238
    • /
    • 2021
  • The aim of this research was to develop a rapid and easy multi-residue method for determining dimethipin, omethoate, dimethipin, chlorfenvinphos and azinphos-methyl in agricultural products (hulled rice, potato, soybean, mandarin and green pepper). Samples were prepared using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) and analyzed using gas chromatography-tandem mass spectrometry (GC-MS/MS). Residual pesticides were extracted with 1% acetic acid in acetonitrile followed by addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. The extracts were cleaned up using MgSO4, primary secondary amine (PSA) and octadecyl (C18). The linearity of the calibration curves, which waas excellent by matrix-matched standards, ranged from 0.005 mg/kg to 0.3 mg/kg and yielded the coefficients of determination (R2) ≥ 0.9934 for all analytes. Average recoveries spiked at three levels (0.01, 0.1, 0.5 mg/kg) and were in the range of 74.2-119.3%, while standard deviation values were less than 14.6%, which is below the Codex guideline (CODEX CAC/GL 40).

A Study on the Threshold Condition of Crack Propagation for Pre-Crack and Micro-Hole Specimens (프리크랙과 微小圓孔材의 크랙成長 下限界條件에 관한 硏究)

  • 송삼홍;윤명진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.278-285
    • /
    • 1988
  • The Critical size of artificially induced micro-holes in 0.17%, 0.36% Carbon steel Specimens with Spheroidized Cementite and in 0.17% carbon steel specimens with martensite structure is compared with annealed pre-crack in order to discuss the physical meaning of the fatigue limit and evaluation of the tolerant micro flaw size at the stress level of the fatigue limit. Results obtained were summarized as follows; (1) In this study, non-propagating crack length of Smooth specimen and critical pre-crack length (lc) is coincide. (2) In the carbon steels with spheroidized cementite structure, critical pre-crack length (lc) and allowable micro-hole size (dc) is coincide each other at the fatigue limit level. (3) It has been published that there exists a particular size of micro-hole which has no effect on the fatigue limit. In this study, the micro-hole of critical size can be regarded as equivalent to a tolerant micro flaw which would not reduce the fatigue limit.

Acceptable Velocity Errors Tolerance For Field Artillery Weapon System (야전포병 무기체계의 속도오차 허용한계)

  • Min Kye-Ryo;Bai Do-Sun
    • Journal of the military operations research society of Korea
    • /
    • v.2 no.1
    • /
    • pp.163-176
    • /
    • 1976
  • The artillery fire is characterized by great damage that can be inflicted simultaneously to an area through concentrated firing. The field artillery guns used in R.O.K. Army are generally old. Thus high values of their velocity errors cause wide dispersion of shell landings. Therefore effects of the concentrated firing is lessened. In this paper a general model which considers all error factors involved in firing in general, is established first. Then from this a basic model which includes the errors involved in concentrated firing only, such as the ballistic error, velocity error, target density function, and damage function, is extracted. Among many weapon systems now in use a specific one called gun 'A' is selected and its concentration effects are measured through computer simulation. The results show that as the velocity error of a battery increases, its target coverage capability, i. e. concentration effect, decreases. Therefore the need arises for the field artillery commander to know beforehand characteristics, i.e. velocity errors, of the guns in his unit and also to carefully examine the problem of battery arrangement with the gun characteristics in mind in order to maximize the damage effects of his artillery unit.

  • PDF

Failure Mode and Fracture Behavior Evaluation of Pipes with Local Wall Thinning Subjected to Bending Load (감육배관의 굽힘하중에 의한 손상모드와 파괴거동 평가)

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Kim, Seon-Jin;Kim, Jin-Hwan;Kim, Hyun-Soo;Do, Jae-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.8-17
    • /
    • 2003
  • Fracture behaviors of pipes with local wall thinning are very important for the integrity of nuclear Power Plant. In Pipes of energy Plants, sometimes, the local wall thinning may result from severe erosion-corrosion (E/C) damage. However, the effects of local wall thinning on strength and fracture behaviors of piping system were not well studied. In this paper, the monotonic bending tests were performed of full-scale carbon steel pipes with local wall thinning. A monotonic bending load was applied to straight pipe specimens by four-point loading at ambient temperature without internal pressure. From the tests, fracture behaviors and fracture strength of locally thinned pipe were manifested systematically. The observed failure modes were divided into four types; ovalization. crack initiation/growth after ovalization, local buckling and crack initiation/growth after local buckling. Also, the strength and the allowable limit of piping system with local wall thinning were evaluated.