• Title/Summary/Keyword: 핵의학검사

Search Result 436, Processing Time 0.033 seconds

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

The Effect on The Result, in Case of the In-vitro Test Performance after an Imaging Test (핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향)

  • Moon, Ki Choon;Kwon, Won Hyun;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.149-152
    • /
    • 2014
  • Purpose: At our hospital blood is collected from a patient before an imaging test, with the concern of any effect possible when a nuclear medicine imaging test and an in-vitro test are carried out at the same time. However, occasionally, the blood collection is performed after an imaging test, with the reasons that the patient is not properly guided or the patient doesn't follow the guide correctly. In that case, we prefer to gather blood again after a few days. The purpose of this study is not only to see whether there is any effect of an imaging test on the result of the in-vitro test performed with the blood collected after the imaging test, but also to study how many days waiting after each test is appropriate to take a blood sample, if the effect exists. Materials and Methods: From September to October 2013, blood were collected from 13 patients in our hospital regardless of age and sex each time before and after the injection of the radioactive isotope from the tests : PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan. Considering a half-life, AFP, CA19-9, CEA, TSH, and T3 were carried out right after the blood collection. In case of an iodine therapy, blood were taken each time before and after taking radioactive iodine, and, after AFP, CA19-9, and CEA, the difference between them in consistency and in cpm were compared. Results: With 10 patients after the imaging tests and 3 patients after the iodine therapy, their serum cpm was over 10,000. Over time, the cpm decreased in accordance with the half-life ($^{18}F$ 110minutes, $^{99}mTc$ 6hours, $^{201}Tl$ 72hours, $^{131}I$ 7days). Between the two cases, one before and the other after the injection of the radioactive isotope, the cpm and the results of AFP, CA19-9, CEA, TSH, and T3 from three patients each test, PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan, were very similar. In addition, in case of an iodine therapy, there was also not a meaningful difference in the cpm and the results of AFP, CA19-9, and CEA, from three patients in an iodine therapy, between the two cases, one before and the other after taking the radioactive iodine. Conclusion: In case a blood collection was performed after the imaging test which required a radioactive isotope injection, the cpm increased, differently according to the kind of the radioactive isotope. However, the results of the in-vitro tests like AFP, CA19-9, CEA, TSH, T3, etc were nearly not affected. As the result, it's considered that there will not be any significant effect also from other tests, as the result from the performed seven tests.

  • PDF

Usefulness of Breast Lymphoscintigraphy after Whole Body Bone Scan (유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성)

  • Jang, Dong-Gun;Bahn, Young-Kag;Chung, Seok;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.133-137
    • /
    • 2010
  • Purpose: Breast cancer is known to be more vulnerable to bone metastasis and lymph node metastasis than other types of cancer, and nuclear examinations whole body bone scan and lymphoscintigraphy are performed commonly before and after breast cancer operation. In case whole body bone scan is performed on the day before lymphoscintigraphy, the radiopharmaceutical taken into and remaining in the bones provides anatomical information for tracking and locating sentinel lymph nodes. Thus, this study purposed to examine how much bone density affects in locating sentinel lymph nodes. Materials and Methods: The subjects of this study were 22 patients (average age $52{\pm}7.2$) who had whole body bone scan and lymphoscintigraphy over two days in our hospital during the period from January to December, 2009. In the blind test, 22 patients (average age $57{\pm}6.5$) who had lymphoscintigraphy using $^{57}Co$ flood phantom were used as a control group. In quantitative analysis, the relative ratio of the background to sentinel lymph nodes was measured by drawing ROIs on sentinel lymph nodes and the background, and in gross examination, each of a nuclear physician and a radiological technologist with five years' or longer field experience examined images through blind test in a five-point scale. Results: In the results of quantitative analysis, the relative ratio of the background to sentinel lymph nodes was 14.2:1 maximum and 8.5:1 ($SD{\pm}3.48$) on the average on the front, and 14.7:1 maximum and 8.5:1 ($SD{\pm}3.42$) on the average on the side. In the results of gross examination, when $^{57}Co$ flood phantom images were compared with images containing bones, the score was relative high as 3.86 ($SD{\pm}0.35$) point for $^{57}Co$ flood phantom images and 4.09 ($SD{\pm}0.42$) for bone images. Conclusion: When whole body bone scan was performed on the day before lymphoscintigraphy, the ratio of the background to sentinel lymph nodes was over 10:1, so there was no problem in locating lymph nodes. In addition, we expect to reduce examination procedures and improve the quality of images by indicating the location of sentinel lymph nodes using bone images as body contour without the use of a source.

  • PDF

Comparing of the Administered Activities and the Effective Dose of the Various Pediatric Dose Formulas of Nuclear Medicine (핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교)

  • Gil, Jong-Won
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.147-154
    • /
    • 2017
  • The purpose of this study is to calculate and compare administered activities(MBq) and effective dose(mSv) of the various pediatric dose formulas of pediatric nuclear medicine and to provide base data for the criteria of the optimal administered activities. This study compares dosages and effective doses of 5 types of pediatric dose formulas(Clark rule, Area rule, Webster rule, Young rule, Solomon(Fried) rule) based on the dosage for adults of 2 types of radiopharmaceuticals($^{99m}Tc$-MDP, $^{99m}Tc$-Pertechnetate). The administered activities in adults, which is the criteria for calculating the Pediatric administered activities, used the value from the 'Nuclear Medicine' written by J-G Jeong & M-Ch Lee. and the administered activities by the radioactivity per effective dose(mSv/MBq) of the radiopharmaceuticals for calculating the effective dose used the value from ICRP 80 and the UNSCEAR 2008 Report. As a result of the study, the output of Young rule is the lowest, and its difference between other formulas is from minimum 1.7 times to maximum 3,4 times. The difference between administered activities of $^{99m}Tc$-MDP is maximum 309.9MBq and the effective dose is 3.76mSv. $^{99m}Tc$-Pertechnetate showed the figure at the maximum 154.9MBq and the effective dose has a difference of 5.50mSv. Since the pediatric dose formulas differ not only in administered activities but also in effective doses, the optimal administered activities have to be developed for optimization of medical radiation.

Study on Development of Patient Effective Dose Calculation Program of Nuclear Medicine Examination (핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구)

  • Seon, Jong-Ryul;Gil, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.657-665
    • /
    • 2017
  • The aim of this study was to develop and distribute a dedicated program that can easily calculate the effective dose of a patient undergoing nuclear medicine examinations, and assist in the study of dose of nuclear medicine examinations and information disclosure. The program produced a database of the effective dose per unit activity administered (mSv/MBq) of the radiopharmaceuticals listed in ICRP 80, 106 Report and the fourth addendum, was designed through Microsoft Visual Basic (In Excel) to take the effect of 5 different (Area, Clark, Solomon(=Fried), Webster, Young) of pediatric dose calculation methods and 7 different body surface area calculation methods. The program calculates the effective dose (mSv) when the age, radionuclide, substance, and amount injected in the human body is inputted. In pediatric cases, when the age is entered, the pediatric method is activated and the pediatric method to be applied can be selected. When the BSA (Body Surface Area) formula is selected in the pediatric calculation method, a selection window for selecting the body surface area calculation method is activated. When the adult dose is input, the infant dose and the effective dose (mSv) are calculated automatically. The patient effective dose calculation program of the nuclear medicine examinations produced in this study is meaningful as a tool for calculating the internal exposure dose of the human body that is most likely to be obtained in nuclear medicine examinations, even though it is not the actual measurement dose. In the future, to increase the utilization of the program, it will be produced as an application that can be used in mobile devices, so that the public can access it easily.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

Measurement of the Spatial Dose Rates During PET/CT Studies (전신 PET/CT 검사에서 공간선량률 측정)

  • Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.257-260
    • /
    • 2006
  • In order to evaluate the exposure to the radiologic technologists from patients who had been administrated with radiopharmaceuticals, we measured the spatial dose rates at $5{\sim}300\;cm$ from skin surface of patients using an proportional digital surveymeter, 1.5(PET scan) and 4hr(bone scan) after injection. In results, the exposure to the technologists in each procedure was small, compared with the dose limits of the medical workers. However, the dose-response relationships in cancer and hereditary effects, referred to as the stochastic effects, have been assumed linear and no threshold models ; therefore, the exposure should be minimized. For this purpose, the measurements of spatial dose rate distributions were thought to be useful.

  • PDF

The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time (스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구)

  • Lee, Jong-Hun;Ryu, Jae-Kwang;Chung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The examination of nuclear medicine observes the change in accordance with the time elapsed in the same region purposed and there are many examinations to acquire the image during the same term. At this time, the same parameter should be applied. The hepatobiliary scan, lung scan etc, are the acquired examination in the divided time with a regular term. Pre-set time that is applied in continued next image is set in order to acquire the fixed counts. The same scan time should be applied for each image. This study will look for the rational plan and analyze the change of scan time in accordance with the time of the decision of scan time at examination that pre-set time is applied. Methods: The hapatobiliary scan that use the radio pharmaceutical $^{99m}Tc$-mebrofenin is choosed as compensation from Jan. 2009 to Mar. 2009 in the department of nuclear medicine in ASAN MEDICAL CENTER. Scan is started after 5 minutes from when 222 MBq (6 mCi) is injected to patient. We let patient stand up between both detectors, and possibly close to the front of detector. When scan time reach 10%, 25%, 50%, 75% of total scan time, we measured the expected total scan time. After finishing all of scan, we compared the total scan time and the expected total scan time, while image is acquiring. and we observed the change of scan time in accordance with radio activity by using phantom. Results: After starting scan, a difference of when scan time reach 10%, 25%, 50%, 75% of total scan time is that the biggest difference is 5 seconds on 10%. There statistically is difference between 25% (t:2.88, p<0.01) and 50% (t:2.05, p<0.01). Conclusions: When the same the scan time is applied in the examination that acquire the many frame, concluding the same scan time has a important effect on a quantitative analysis. Although method that decide the scan time after finish all of the examinations, there is a few problem to apply practical affairs. This may cause an inaccurate result on the examination that need a quantitative analysis. We think that operator should try to improve it. At least, after reach 50% of total scan time, deciding the total scan time mean that you can minimize error of a quantitative analysis caused by unmatched scan time from a gap of image.

  • PDF

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF