• Title/Summary/Keyword: 해부학적 구조

Search Result 417, Processing Time 0.026 seconds

Anatomical study of Atractylodes japonica Koidz. ex Kitam. and A. macrocephaza Koidz. (삽주(Atractylodes japonica Koidz. ex Kitam.)와 큰꽃삽주(A. macrocephala Koidz.)의 해부학적 연구)

  • 정규영;김미숙
    • Korean Journal of Plant Resources
    • /
    • v.14 no.3
    • /
    • pp.188-195
    • /
    • 2001
  • The anatomical characteristics of rhizome, lateral root, stem, leaf, petiole, ovary and leaf epidermis about Atractylodes japonica Koidz. ex Kitam. and A. macrocephala Koidz. were investigated to estimate these taxonomic values. The cross sections of stem and ovary were very similar to two species, therefore these characters were not useful for delimitation of two species, but the size and distribution numbers per 100${\mu}{\textrm}{m}$$^2$of oil cavites in rhizome, the shape of leaf and petiole in cross section, the size of leaf epidermal cell and distribution numbers per 100 ${\mu}{\textrm}{m}$$^2$of stomata were differ from two species, therefore these were thought to be useful characters for delimitation of two species.

  • PDF

Computer Modeling Techniques for Teeth Reconstruction System (치아재건 시스템을 위한 컴퓨터 모델링 기술)

  • 엄성권;김병오;유재수;유관희
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.598-600
    • /
    • 1999
  • 본 논문은 수공으로 이루어지는 치과 치료 및 보철물 제작을 3차원 컴퓨터 모델링을 하여 좀 더 정확하고 빠른 시간에 처리할 수 있는 시스템을 소개한다. 이 시스템은 기존 2차원 기반이 아닌 3차원 기반으로 설계되었으며, 구강의 석고 모형을 3차원으로 컴퓨터에 모델링한 후, 모델링 정보로부터 능선(ridge), 교두(crusp), 피트(pit), 열구(fissure), 변연(margin) 등과 같은 치아 특성 정보추출과 교합면 생성을 통하여 보철물, 예를 들어 Conus 내관과 외관을 제작한다. 해부학적으로 무수히 많은 변수를 갖고 있는 구강 구조에 대해 본 논문에서는 이들 일련의 과정에서 요구되는 컴퓨터 모델링의 주요 기술들을 제시한다.

  • PDF

Anatomical Characteristics of the Mandibular Median Lingual Foramen: the Assessment of the CBCT (CBCT를 이용한 하악 정중설공의 해부학적 평가)

  • Lee, Go-Woon;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.337-346
    • /
    • 2013
  • It is necessary to consider the median lingual foramen carefully to prevent the bleeding due to the damage of the sublingual artery for implant surgery. This study is to evaluate the frequency, location, diameter and the number of the Mandibular median lingual foramen regarding gender and age in the CBCT. Sixty two images of cone beam computed tomography (CBCT) whose visited the Chonnam National University Dental hospital from Sept. 2010 to Apr. 2011 were evaluated. Frequency, number, location and the diameter of Mandibular median lingual foramen shown in the CBCT image were evaluated. Sixty two patients (100%) had at least one median lingual foramen and fifty six patients (90.32%) had multiple foramens. Forty patients (66.13%) showed the median lingual foramen on the location between Mn. central incisors. The mean vertical position of the genial spine and the median lingual foramen was 24.21 mm and 14.52 mm, respectively. And the relative mean vertical dimension of median lingual foramen was 0.45. The mean diameter of the foramen was 0.93 mm. CBCT demonstrated the frequency, location, diameter and the number of median lingual foramen. It is necessary to take CBCT before implant placement to prevent the bleeding.

A Study on 3D Surface Reconstruction for the Breast of Human Body (인체 가슴 부위의 구조물의 3D 표면 모형 재구성)

  • Lee, Sang-Tae;Jeon, Hyun-Jin;Kim, Ki-Tai;Choi, Ki-Seok;Joo, Won-Kyun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.99-102
    • /
    • 2009
  • 본 연구에서는 실제 기증받은 시체를 이용하여 인체의 각 구조물을 실제 모습 그대로 3D 이미지화하는 과정에 대해 알아보았다. 인체의 구조물을 3D 로 이미지화하는 과정은 다음과 같다. 먼저 시체를 0.2mm 간격으로 절단하여 절단면의 사진을 찍은 후, 각 절단면의 사진에서 각각의 구조물을 구역화하여 색칠을 한 후, 구역화한 이미지에서 외곽선을 추출하여 벡터 이미지를 만든다. 이 외곽선을 1mm 간격으로 쌓아 올린 후 그 표면을 재구성하여 3D 이미지로 변환하는 과정으로 진행되었다. 3D 이미지의 제작은 가슴 부위에 한정하여 이루어졌다. 인체의 해부학적인 모형을 3D 이미지로 시각화함으로써 얻는 효과는 일반인을 대상으로 인체의 내부에 대한 시각적인 호기심을 충족시켜주고 의학 상식을 넓히는데 도움을 줄 수 있을 것 이다. 또한 의대생들을 비롯한 의학 전문가들에게는 생생한 해부학 강의용으로도 활용 가능하다. 향후 Haptic 시스템을 이용한 의료 실습 어플리케이션과 접목될 수도 있을것이고, fMRI 데이터를 비롯한 타 데이터와의 융합을 통해 시각화하여 서비스 할 수도 있다. 이처럼 인체의 3D 모형은 의료분야에서 광범위하게 활용될 수 있는 데이터로써 그 가치를 지닐 것이다.

  • PDF

The nutlet morphology of the genus Glechoma L. (Lamiaceae) and its related taxa (긴병꽃풀속(Glechoma L. 꿀풀과) 및 근연분류군의 소견과 형태에 관한 연구)

  • Jang, Tae-Soo;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.40 no.1
    • /
    • pp.50-58
    • /
    • 2010
  • The nutlet morphology and pericarp structure of 14 taxa (4 taxa of the genus Glechoma and related taxa) were studied by light and scanning electron microscopy, and a detailed description of nutlet morphological features for all examined taxa is provided. The shape of the nutlet is ovate to elliptic. Its size is 1.36-3.83 mm in length and 0.80-2.65 mm in width. The largest one was found in Marmoritis rotundifolia, while the smallest one was in Agastache nepetoides. Three different surface types were recognized in the studied taxa based on differences in cell outline and cell boundary relief (rectangular, pitted, and ridged negative reticulate-cell). Three types of trichome (uni-cellular non-glandular trichome, multi-cellular non-glandular trichome, and peltate glandular trichome) were distributed in the nutlets. The pericarp is formed in three layers (i.e., exocarp, mesocarp, and endocarp including sclenchyma tissue), and the pericarp in the studied species is $39.0-237.5{\mu}m$ thick. The morphological and anatomical features (the nutlet shape, surface type, and trichome distribution) in the genus Glechoma and related taxa are described and discussed.

Recent Issues in Musculoskeletal Anatomy Research and Correlation with MRI (근골격 해부학의 최신 지견 및 자기공명영상 소견)

  • Hyerim Park; Joon-Yong Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.2-20
    • /
    • 2020
  • MRI is a valuable imaging technique for the evaluation of intraarticular diseases. Accurate interpretation of joint MRI necessitates sound knowledge of anatomy. In the field of joint anatomy, in addition to the discovery of new structures, previously reported joint components of unexplained function are also detected. In this review, joint anatomy researched actively over the last decade is discussed. Joint components including the rotator cable and the superior capsule of the shoulder, posterolateral corner and the anterolateral ligament complex of the knee, and the distal tibiofibular syndesmosis of the ankle joint are introduced and correlated with their MRI features.

Normal Anatomy of the Wrist Joint (손목 관절의 해부학)

  • Kang, Hong Je
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • The wrist joint was consisted with various bones, ligaments, and muscles. The wrist joint is difficult to understand, because of its complicated anatomical structure. The wrist joint is not one space but three joints; radiocarpal joint between distal radioulnar and proximal carpal bone, midcarpal joint between proximal and distal carpal bone, and distal radioulnar joint between distal radius and ulnar head. Normally each joint is separated from each other. Exact understanding about normal anatomy of the wrist joint is necessary for treatment of disease and injury in wrist joint. In this reviews, we will see normal anatomy of the wrist joint.

  • PDF

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.

THE MEDIAL SIGMOID DEPRESSION: Its Anatomic and Radiographic Considerations (하악골과 방사선사진상에서의 하악절흔 내측 함요)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 1991
  • An anatomic radiolucency called medial sigmoid depression can be observed on a number of panoramic and mandibular oblique lateral views in the ramus just below and anterior to the mandibular sigmoid notch. The radiolucency may be unilateral or bilateral. Seventy-eight mandibles of dry skulls were visually examined and radiographed by panoramic machine. The observable incidence, the location center, and the mean size of the medial sigmoid depression were studied. Additionally, the radiographic incidence of the depression was determined using 500 panoramic radiographs. Normal anatomic radiolucent areas in the jaws are encountered often in the radiographs taken for the usual dental practice purpose. Some of these radiolucencies can be misdiagnosed as pathologic entities. But in most cases, the size, location, and appearance of the radiolucent area, and the presence or absence of symptoms can lead one to the correct diagnosis before surgery is undertaken. And this can be secured if diagnosticians are aware of the common and varied appearances of the normal anatomic radiolucencies A depression in the ramus just below and slightly anterior to the most inferior aspect of mandibular sigmoid notch shows occasionally foramen-like or notch-like radiolucency on some panoramic and oblique lateral views. This radiolucency was named medial sigmoid depression by Langlais et a1. in 1983. Since there're no reports about this medial sigmoid depression after that, (The author retrieved the Mediline from 1983 to 1990: Cambridge scientific abstracts, (7200 Wisconsin Ave Bethesda MD 20814 U.S.A.) National Library of Medicine) the author studied the size and the location of the depression of the mandible specimens, and determined the relationship between the observable anatomic incidence and its reproducibility on the radiographs.

  • PDF