• 제목/요약/키워드: 항온조

검색결과 76건 처리시간 0.035초

제한효소 반응용 PDMS/유리 마이크로 항온조 제작 및 특성평가 (Study on PDMS/Class Microthermostat Fabrication and Evaluation for Restriction Enzyme Reaction)

  • 진석호;조용진;안유민
    • 대한기계학회논문집A
    • /
    • 제28권10호
    • /
    • pp.1598-1602
    • /
    • 2004
  • In this paper, we report a microthermostat using PDMS (poly-dimethylsiloxane) and glass. This PDMS/glass chip is able to maintain constant temperature that is necessary for restriction enzyme reaction. Since PDMS is the low-cost and the mass-producible material and has very good biochemical compatibility, PDMS chip has more benefit than general Si chip. Heater was made of Au wiring patterned on Pyrex glass. A reaction chamber has a capacity of about 3 ${mu}ell$. We performed a restriction enzyme reaction by using the fabricated microthermostat and conventional method. Then, with the electrophoresis, we made a comparison between the result from the micro reactor and the one from conventional method.

태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구 (A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy)

  • 윤준규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.324-331
    • /
    • 2013
  • 이중진공관형 집열기는 진공기술을 이용하여 흡수면에서 대류열손실을 줄일 수 있으며, 비교적 적은 온도차에서도 열수송능력과 열응답성이 빠른 이점이 있어 유용한 기기로 연구가 지속적으로 진행되고 있다. 본 연구에서는 태양열 집열기와 냉동기가 조합한 성능실험장치를 이용하여 태양열의 일사량, 유체온도의 제어조건에 따른 집열기의 동적 열성능을 파악하고, 이에 따른 항온조를 이용한 유체의 일정한 온도범위에서 냉동성능을 동시에 측정하여 열역학적 특성을 고찰하였다. 그 결과로서 집열효율의 관계식을 도출하였으며, 항온조의 출구온도 $18^{\circ}C$$22^{\circ}C$에서 집열기의 출구온도 $25^{\circ}C$로 설정하였을 때 항온조의 출구온도 $22^{\circ}C$ 경우가 외기온도 및 일사량이 증가함으로써 빠른 열전달특성을 보여 평균집열효율이 상승됨을 보였다. 또한 항온조의 출구온도 $18^{\circ}C$에서 냉동기의 성능계수는 6.2~7.1 정도의 결과를 얻게 되었다.

국가표준 유지용 교류저항 표준기 개발 및 그 특성 (Development and It's Characteristics of AC Resistance Standards for Maintaining National Standard)

  • 김한준;유광민;강전홍;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2055_2056
    • /
    • 2009
  • 국가표준을 유지하기위한 표준기급의 교류저항은 상품화된 것이 외국에서 한 종류 있으나 고정된 기름 항온조에서 유지를 해야 하고, 정전차폐가 어렵고, 교류에서 측정단자의 호환성이 어렵고 가격도 대단히 비싸다. 또한 저항체가 지지대 역할을 하는 원형 보빈에 감겨져있는 선으로 구성되어서 국제비교시나 혹은 이동교정시에 기계적인 구조의 변화로 저항 값에 영향을 받기가 쉽다. 이러한 단점들을 극복한 교류저항 표준기가 개발이 되었다. 개발된 표준기는 저항체의 기계적 구조에 의한 변화를 막기 위해서 non-inductive 구조의 metal foil element로 제작된 것을 사용하였으며, 각각의 저항체에 개개의 항온조를 체택함으로서 온도의 안정성과 이동의 편리를 함께 만족되도록 하였다. 제작된 교류저항 표준기의 특성은 온도 안정도가 ${\pm}5$ mK/d, 저항값의 안정도가 ${\pm}0.01{\mu}{\Omega}/{\Omega}/d$, 1년간의 장기안정도가 $1{\mu}{\Omega}/{\Omega}$ 이하로 측정이 되었다. 개발된 교류저항 표준기는 교류저항분야 국가표준유지 및 소급에 사용이 된다.

  • PDF

파일롯 투과증발장치에서 투과액의 상전이외 체류액의 온도강하에 관한 연구

  • 송규민;홍원희
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.90-91
    • /
    • 1996
  • 투과증발은 일반 막공정과 달리 투과물의 상전이와 이로 인한 체류액의 온도강하가 존재하기 때문에 열전달현상을 간과할 수 없다. 즉 막을 통한 열전달이 다른 막공정에 비해 현저하게 차이가 난다는 것이다. 이러한 현상은 모듈의 길이가 짧거나 모듈을 항온조에 담가 수행하는 실험실 규모의 투과증발조업에서는 거의 발견되지 않는다. 그러나 투과증발장치가 커져 모듈의 항온유지가 블가능하고 사용되는 막도 상업화되어 투과속도가 비교적 큰 것을 사용하는 파일롯 규모의 실험에서는 쉽게 나타나는 현상이다. Rautenbach등이 셀룰로오즈 아세테이트 막을 이용한 물의 투과증발 실험에서 막간 온도강하가 5~12 K정도 일어났음을 보고한 바 있었다. 이때 온도강하는 조업조건에 따라 달라졌으며 유속이 낮을 수록 증가함을 보였다. 본 연구에서는 투과증발이 일어나는 모듈내에서 열전달현상을 열공급비를 정의하여 해석하였으며, 상전이 현상이 막분리효율에 끼치는 영향을 설명하였다.

  • PDF

식용곤충(食用昆蟲)으로서 누에 성장에 따른 아미노산함량(含量) 변화(變化)에 관한 연구(硏究) (Studies on the amino acid change in silkworm and silkworm-chrysalis as an edible insect)

  • 남현근
    • 한국식품영양과학회지
    • /
    • 제4권1호
    • /
    • pp.59-66
    • /
    • 1975
  • 식용곤충(食用昆蟲)으로서 누에와 번데기를 분석(分析)하여 단백질(蛋白質)과 amino acid 함량(含量)을 알았고 이를 이용(利用)할 수 있는 가능성(可能性)을 알아보았다. (1) 누에와 번데기에 대(對)하여 단백질(蛋白質)을 정량(定量)한 결과(結果), $54.9{\sim}56%$ 정도의 단백질(蛋白質)이 함유(含有)되어 있음을 알았다. (2) 유리아미노산의 정량(定量)과 조성(組成)을 조사하였더니 tryptophan 을 제외(除外)한 대부분(大部分)의 아미노산이 함유되어 있으며 성장하여감에 따라 함량(含量)도 크게 변(變)하고 있음을 알게 되었다. (3) 탄수화물(炭水化物)로서 sucrose, glucose, fructose가 함유(含有)되어 있음을 확인하였다. (4) milk와의 반응(反應)을 $40^{\circ}C$ 항온조에서 방치하면서 pH와 산도변화(酸度變化)를 보았는데, 약 8시간(時間)동안 $40^{\circ}C$ 항온조에 놓아두는 경우 산도(酸度)는 약 8시간(時間)동안에는 별 변동이 없고, 그 후(後)에 변화(變化)가 심했다.

  • PDF

다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석 (Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources)

  • 김재중;손영갑;장석원;유동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

Inulin의 산 가수분해 반응에서 초음파가 미치는 영향 (Effect of Ultrasound on the Acid Hydrolysis of Inulin)

  • 김성배;윤석준
    • KSBB Journal
    • /
    • 제8권4호
    • /
    • pp.358-363
    • /
    • 1993
  • 부산물이 거의 생기지 않는 반응조건에서 inulin의 산 가수분해 반응에 미치는 초음파의 영향을 조사했다. 반응조건은 50~$60^{\circ}C$와 염산 0.1~0.3%(w/w)의 상당히 완화된 범위였으며, 항온조 내 반응기 위치와 기계적인 교반에 대한 영향을 조사했다. 초음파를 사용한 경우와 하지 않은 경우 fructose생성속도를 온도와 산의 농도변화에 따라 비교했으며 두 경우 활성화에너지는 25kcal/mol로 같았다. 초음파에 의한 반응속도 증가는 평균 22%였다.

  • PDF

표준전지 및 표준전지 항온함 제작에 관한 연구 (A Study on the Standard Cell and Its Enclosure)

  • 황의진;이화심;이진욱;강홍열
    • 대한화학회지
    • /
    • 제36권6호
    • /
    • pp.857-863
    • /
    • 1992
  • 기전력의 단위인 volt를 유지하기 위하여 사용되는 Weston 산성 포화전지를 만들어, 온도가 일정하도록 특별히 고안하여 제작한 enclosure에 넣어 성능을 평가하였다. 전지 제조에 사용되는 황산카드뮴은 진공 상태에서 재결정하였으며, 수은이 분산된 황산수은(I) 침전은 전기분해에 의해 제조하였으며, 카드뮴 아말감도 전기분해에 의하여 정확한 조성으로 제조할 수 있었다. 표준전지 항온함은 순환식 항온조를 이용하여 제작하였으며, 실내 온도가 심하게 변하는 경우에도 ${\pm}$5 mK 이내로 표준전지의 온도를 안정시킬 수 있었다. 표준전지의 기전력을 5${\sim} 30^{\circ}C$의 온도 범위에서 측정하였으며 전지간의 기전력 표준편차는 약 1ppm이었다.

  • PDF

결정립 조대화된 기계적 합금화 ODS NiAl의 Creep 성질 (Creep Properties of Grain Coarsened ODS MA NiAl)

  • 어순철;서성재
    • 한국재료학회지
    • /
    • 제7권11호
    • /
    • pp.942-950
    • /
    • 1997
  • NiAI기 산화물 분산강화(Oxide Dispersion Strengthende:ODS)합금을 기계적 합금화 (Mechanical Alloying: MA)방법으로 제조하였으며, 열간압축방법으로 성형하였다. 연이어 단순항온처리에 의한 정상결정립성장과 특성조건에서의 thermomechanical treatment 에 의한 이차재결정화를 유도하였다. 결정립 조대화된 ODSD MA NiAI의 creep 성질 및 이에 조대화된 미세조직은 creep 성질이 저하된 반면, 이차재결정화된 MA NiAI의 creep성질은 크게 향상되었다. 이 creep 성질의 향상은 이차재결정화의 특성인 급격한 결정립의 조대화, 분산상의 성장억제 및 grain aspect ratio의 증가에 기인한 것으로 사료되었다. 이차재결정화된 ODS MA NiAI의 creep또는 glide controlled dislocation creep임을 제시하지만, 전체 creep속도가 결정립 크기 및 grain aspect ratio의 영향을 크게 받은 것을 볼 때, 결정립계 미끄럼기구가 주 creep 기구와 조합되어 MA NiAI의 전체 creep기구에 영향을 준 것으로 추정할 수 있었다.

  • PDF

생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구 (Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia)

  • 박일형;김신근;신동규;인주철
    • 대한골관절종양학회지
    • /
    • 제1권1호
    • /
    • pp.7-16
    • /
    • 1995
  • 인체골 4 시편(specimen)과 돼지 경골 25쌍을 이용하여, 생체골의 열전도성 측정과 열처리후 열처리온도와 시간에 따른 골의 염전력을 실험한 결과를 요약하면 다음과 같다. 인체골에 있어서 골수강을 제거하지 않고 $60^{\circ}C$의 항온식염수에서 열처리하면, 골심부의 온도가 $20^{\circ}C$에서 $58^{\circ}C$에 도달하는데 소요된 시간은 경골근위부가 32분 50초, 대퇴골 원위부가 30.분, $80^{\circ}C$ 항온조에서는 경골근위부가 12분 50초, 대퇴골 원위부가 11분 10초 소요되었다. 돼지 경골간부의 피질골내부(endosteum)에 열전대를 부착하고 뼈 양끝을 밀봉하여 같은 실험을 행한 결과 $50^{\circ}C$까지는 시간에 비례해서 일정한 비율로 온도상승이 이루어 졌으며, $20^{\circ}C$에서 $58^{\circ}C$에 이르는 시간이 $60^{\circ}C$ 항온조에서는 7분, $70^{\circ}C$에서는 3분 30초, $80^{\circ}C$에서는 2분이었다. 따라서 임상에서 골수강을 제거 후 장골의 간부(shaft) 만을 항온조에 달굴때는 골구강내에도 데워진 심염수로 가득차게 되므로 상기 시간의 절반이 못되는 짧은 시간내에 피질골의 내부가 $58^{\circ}C$에 이르리라고 판단되었다. 골수강을 소파하지 않은 돼지 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$ 35분, $80^{\circ}C$ 15분 열처리한 후 실험군의 최대염전력은 대조군과 비교할 때 +7.0%, -5.1%, -3.2%, -4.2%의 변화가 있었고, $80^{\circ}C$ 15분 열처리후는 -4.3%, -3.8%, -1.4%(1예는 실험 오류로 제외됨)의 변화가 있었다. 골수강을 완전 제거한 되재 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$, $70^{\circ}C$, $80^{\circ}C$에서 15분 열처리 후 실험군의 최대염전력은 대조군과 비교할 때 -3.4%, -4.2%, -0.7%, +2.7%의 변화가 있었고, $70^{\circ}C$ 15분 열처리후는 -2.8%, -3.9%, -2.1%(1예는 실험 오류로 제외됨)의 변화가 있었으며, $80^{\circ}C$ 15분 열처리후는 +5.2%, -4.4%, -2.9%, -0.3%의 염전력 변화가 있었다. 그러므로 골수강을 제거하지 않고 $80^{\circ}C$ 35분, $60^{\circ}C$ 15분 열처리 하거나, 골수강을 완전소파 후 $60^{\circ}C$ 15분, $70^{\circ}C$ 15분, $80^{\circ}C$ 15분 열처리해서는 각군사이에 염전력의 유의한 차이는없었다. 이상의 결과로 돼지 경골의 경우 $60^{\circ}C$ 항온에서는 35분까지, $80^{\circ}C$이하의 항온에서는 15분까지 열처리하여도 골강도에는 거의 영향이 없는 것으로 나타났다.

  • PDF