• Title/Summary/Keyword: 합성부재

Search Result 254, Processing Time 0.021 seconds

Analysis of a Load Carrying Behavior of Shear Connection at the Interface of the Steel-Concrete Composite Beam (합성보 전단연결부의 구조거동에 대한 비교 분석)

  • Shin, Hyun Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.737-747
    • /
    • 2005
  • The connection of the slab with the steel beam and thus, the transmission of shear force at the interface of the steel-concrete composite beams is achieved with shear connectors, in general, with shear studs. The composite action through these shear studs has a significant influence on the load carrying behavior of the composite beams. The load carrying capacity of studs is determined through push-out tests. At present, the transferability of this load carrying capacity of studs to composite beams, especially in cases of partial interaction, is being questioned by experimental and theoretical investigations. In this study, a finite element model for the simulation of the behavior of the standard push-out specimen and the composite beams without the implementation of the load-slip curve of the stud connectors from the push-out test is developed. The load carrying behavior of the studs in the composite beams is estimated and compared with the results of the push-out test. The reason for the difference in the load carrying behavior of the studs in the push-out test specimen and in the composite beams is found.

Analysis of Compressive Fracture Behavior of Filled FRP Composite Box Module (충전형 FRP 합성박스 모듈의 압축파괴 거동 분석)

  • Kim, Ho-Sun;Jang, Hwa-Sup;Lee, Ho-Hyun;Yun, Kuk-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study is a basic experimental research to apply FRP (Fiber Reinforced Polymer) box members to slabs and girders among various architectural structures, which receive bending stress. We prepared prefabricated FRP member and connected it to an FRP box member as a large cross section before we conducted an experiment in diverse conditions to analyze characteristics of compressive fracture behavior. In this study, we carried out a compressive fracture behavior test according to fillers on the upper part of the FRP box member, loading methods, and connective types and thereby performed a finite element analysis. The comparison of analysis results with test results revealed that rigidity was found to be slightly low, while stress was concentrated on the fracture point of the sample.

Evaluation of the Genetic Toxicity of Synthetic Chemicals (Ⅸ) a Synthetic Selective Herbicide, Pretilachlor- (합성화학물질들의 유전독성평가(Ⅸ) -합성 제초제 Pretilachlor -)

  • Ryu Jae-Chun;Kim Youn-Jung
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.1
    • /
    • pp.93-100
    • /
    • 2004
  • Pretilachlor [2-chloro-N -(2, 6-diethylphenyl)-N-(2-propoxyethyl) acetamide, $C_{17}$H$_{26}$ClNo$_2$, M.W.=311.9, CAS No.51218-49-6]는 제초제의 일종으로 본 연구에서는 박테리아 복귀 돌연변이 시험과 포유동물 세포를 이용한 염색체 이상 시험 및 마우스를 이용한 in vivo소핵 시험을 수행하여 pretilachlor의 유전독성을 평가하였다. 박테리아 복귀 돌연변이 시험에서 pretilachlor는 Salmonella typhimurium TA98, TA 100, TA1535, TA1537 균주의 대사 활성계 존재 및 부재시 313-5,000$\mu\textrm{g}$/plate의 범위에서 농도 의존적인 돌연변이 율의 증가를 관찰할 수 없었다. 또한 포유동물 세포인 Chinese hamster lung (CHL) fibroblast를 이용한 염색체 이상 시험에서 pretilachlor는 대사 활성계 존재 및 부재시 1.56-6.24$\mu\textrm{g}$/mL의 농도에서 clastogenicity를 보이지 않았고, 137.5-550.1 mg/kg의 pretilachlor를 복강 주사한 마우스의 골수세포를 이용한 in vivo소핵 시험의 결과에서도 통계적으로 유의한 소핵 유발능을 관찰할 수 없었다었다

An Analysis of Influence Factors on Insitu-production and Installation Schedule of Composite Precast Concrete Members (합성 PC 부재의 현장생산 및 설치 공정계획의 영향요소 분석)

  • Lim, Chaeyeon;Kim, Sun Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.176-177
    • /
    • 2013
  • The composite PC rahmen structure, called Green Frame, allows the main structural members such as PC column and beam to be produced on the site, resulting in a reduction of PC member transportation cost and the margin of PC plant (operation cost and profit), making it more economic than the bearing wall structure. To apply the Green Frame to practice, not only installation but also insitu-production process should be considered. Therefore, this study analyse the influence factors on insitu-production and installation schedule of composite precast concrete members. The results shall be used as basic criteria on the planning of insitu-production and installation of Green Frame.

  • PDF

Study on the Flexible Strength of U-shape Hybrid Composite Beam (신형상 U형 하이브리드 합성보의 휨성능에 대한 연구)

  • Kim, Sung-Bae;Kim, Sang-Seup;Lee, Won-Rok;Kim, Jung-Yeon;Lee, Seung-Bae;Ryu, Deog-Su;Kim, Dae-Hoi
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.521-534
    • /
    • 2012
  • In this research, we carry this study into effect on the basis of utilizing character of composite beam and developing applicable section to some of high strength steel. We evaluated flexural capacity of composite beam that is a unit member through experiments. The existing nominal strength formula of Composite Beam which is a previous method was reviewed and the experiment had been progressive by using each composite members as main variables though the result. Capacity evaluation of U-shape Hybrid Forming Beam(HyFo Beam) which is a new shape show as follow from the result. First, it is resonable to resist demand moment by couple moments which are occurred in concrete compressive-strength and steel tensile-strength. Second, the capacity was stably increased in proportion to the depth of beams and the thickness of steel plates. The last, HyFo Beam was showed as ductile behavior.

Shear Strength of Steel Fiber Concrete - Plain Concrete Composite Beams (강섬유보강 콘크리트와 일반 콘크리트 합성보의 전단강도)

  • Kim, Chul-Goo;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.501-510
    • /
    • 2015
  • Composite construction of precast concrete and cast-in-place concrete is currently used for the modular construction. In this case, the use of steel fiber reinforced concrete (SFRC) could be beneficial for precast concrete. However, the shear strength of such composite members (SFRC and cast-in-place concrete) is not clearly defined in current design codes. In the present study, steel fiber composite beam tests were conducted to evaluate the effect of steel fibers on the composite members. The test variables are the area ratio of SFRC and shear reinforcement ratio. The test results showed that when minimum horizontal shear reinforcement was used, the shear strength of composite beams increased in proportion to the area ratio of steel fiber reinforced concrete. However, because of the steel fiber, the composite beams were susceptible to horizontal shear failure. Thus, minimum horizontal shear reinforcement is required for SFRC composite beams.

The Structural Economical Efficiency Evaluation of Partially Restrained Composite CFT Column-to-Beam Connection (합성반강접 CFT기둥-보 접합부 구조의 경제성 평가)

  • Kim, Sun-Hee;Bang, Jung-Seok;Park, Young-Wook;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 2012
  • This study seeks to devise a design application for a beam structure with partially restrained composite connection to a CFT column. A cost-efficient and stable component is applied by adjusting the stiffness ratio of the column connection through partially restrained composite connection. Based on a review of the structure's stability, it was confirmed that in the case of a low-rise building as a moment frame, resistance without bracing is feasible because stiffness increased by virtue of the partial restrained composite connection by composite action. In the case of a high-rise building, lateral resistance load of moment frame was approximately 10% when proper partial restrained rate was at around 60%. With considerations related to economic efficiency, the partial restriction effect of the beam component was significantly activated by the uniform load, but that of the beam activated by concentrated load was not significantly indicative. The analysis indicated that 60% partial restrained girder at the connection was the most economical in the case of uniform load. It also showed that end moments can be reduced by approximately 25%.

Shear Strength of Prestressed PC-CIP Composite Beams without Vertical Shear Reinforcements (수직전단보강이 없는 PS 콘크리트와 현장타설 콘크리트 합성보의 전단강도)

  • Kim, Chul-Goo;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min;Suh, Jung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.533-543
    • /
    • 2014
  • Currently, composite construction of prestressed Precast Concrete (PC) and Cast-In-Place (CIP) concrete with different concrete strengths are frequently used in the modular construction. However, current design codes do not clearly define shear design methods for such composite beams. In this present study, simply supported prestressed PC-CIP composite beams without vertical shear reinforcement or only with horizontal shear reinforcement were tested to evaluate the effect of prestressing on the shear strength and the shear design method for such composite members. The test variables were the area ratio of PC and CIP concretes, prestressing force, shear span-to-depth ratio, and shear reinforcement ratio. The results showed that the shear strength was increased by the increase of prestressing force and prestressed PC area, and the decrease of shear span-to-depth ratio.

GFRP로 보강된 교량구조물의 구조안전성 평가 사례 연구

  • 은충기;채원규;손영현;홍성욱;김광일
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.391-396
    • /
    • 2003
  • 최근 차량하중의 대형화에 의해 교량구조물은 사용년수가 증가함에 따라 노후손상에 의해 당초의 설계능력을 발휘하지 못하는 경우가 종종 있으며, 이에 대해 교량구조물의 내하력을 증강시키기 위하여 여러 가지 보수 보강 공법들이 사용되고 있다. 특히 재료의 내부식성, 친환경성 등을 고려하여 GFRP(Glass Fiber Reinforced Plastic)에 의한 보강이 점차 증가하는 추세에 있으나, 아직까지 기존 철근콘크리트 부재와 보강되는 GFRP 부재의 합성에 의한 해석기술에 대한 연구가 많지 않은 실정이다.(중략)

  • PDF

An Experimental Study on the Structural Behavior of Steel-Concrete Composite Rahmen Bridge with Hinged End Supports (하단힌지 강합성 라멘교의 구조적 거동에 대한 실험적 연구)

  • Choi, Jin Woo;Jang, Min Jun;Cheon, Jin Uk;Yoon, Soon Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.195-205
    • /
    • 2015
  • The rahmen bridge is well known common type of bridge in which all members are connected rigidly. The rahmen bridge is built for several situations because it has many advantages such as no need of bridge bearing system, easy of maintenance, reduction of the cross-sectional area of superstructure, and relatively low construction cost compared with other bridge types. Recently, to lengthen the span of rahmen bridge system, steel-concrete composite beam is used for superstructure of rahmen bridge instead of normal concrete girder with slab. However, member forces are increased because of extension of span length of superstructure and substructure is designed and constructed inefficiently when steel-concrete composite rahmen bridge is designed. In this study, new-type steel-concrete composite bridge is suggested. New-type steel-concrete composite rahmen bridge is adopted hinge connection between abutment and foundation for the reduction of the bending momemt at the foundation. In this study, we present the results of experiment conducted to estimate the load carrying capacity of new-type steel-concrete composite rahmen bridge and the structural characteristics of hinge connection.