• Title/Summary/Keyword: 한학(漢學)

Search Result 144, Processing Time 0.025 seconds

Removal Characteristics of Rainwater Including Non-point Pollutants Using Pre-filter of Wasted-tire and Non-woven Fabric (폐타이어와 부직포를 이용한 프리필터에 의한 비점오염원 포함 우수 처리 특성)

  • Yoo, Kyuseon;Han, Hakyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.655-659
    • /
    • 2005
  • Pre-filter system that was consisted of wasted-tire, non-woven fabrics, and sponge was developed as a primary treatment process prior to rainwater reservation or a pre-treatment process of rainwater reuse system for reclamation. By using this system, SS concentration, TOC, COD, and turbidity could decreased by 86.7%, 62.6%, 69.1% and 66.5%, respectively. From the results of particle size distribution of treated water, the particles over than $30{\mu}m$ of diameter were completely removed by pre-filter system. But 90% of particles less than $20{\mu}m$ of diameter were passed through pre-filter. Optimal depth of wasted-tire and non-woven fabrics were 15cm and 2.4cm, respectively. Pre-filter system was considered as an effective alternative for pre-treatment of rainwater including non-point pollutants and it could be also applied for the treatment of combined sewer overflow (CSO).

Operation and Verification of the Real-time Discharge Measurement System Using ADVM on Backwater Conditions (배수영향 하천의 ADVM 방식 자동유량측정시설 운영 및 검증)

  • Cho, Sang-Uk;Kim, Dae-Young;Han, Hak-Young;Kim, Chi-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1850-1854
    • /
    • 2009
  • 금강하구언 상류에 위치한 규암 지점은 배수영향을 받는 지점으로 2007년도에 ADVM (Acoustic Doppler Velocity Meter)방식 자동유량측정시설을 설치하여 운영 중에 있다. 본 연구에서는 규암 지점 자동유량측정 시설에서 측정된 유량측정성과를 분석하고 다양한 방법을 통해 이를 검증하였다. 그 결과 기존 수위-유량관 계곡선식으로 방류영향 지역의 유량변화를 잘 나타낸 결과를 보였으며, 유량의 경우 총 67회 측정한 검증자료와 평균오차 7.2%로 대체로 비슷하게 산정되었으며, 금강하구언의 방류량과 갑문개방기간 동안 규암 지점의 총 유출량을 비교한 결과 3.2%의 오차를 보여 규암 지점 자동유량측정시설의 측정결과에 큰 신뢰도를 보였다.

  • PDF

Dimension Reduction Method of Feature Vector for Real-Time Adaptation of Voice Activity Detection (음성 구간 검출기의 실시간 적응화를 위한 특징 벡터의 차원 축소 방법)

  • Kim Pyoung-Hwan;Han Hag-Yong;Kim Chang-Keun;Koh Si-Young;Hur Kang-In
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.53-56
    • /
    • 2004
  • 본 논문은 잡음 환경하에서 특징 벡터의 차원 축소를 통한 음성 구간 검출에 관한 연구이다. 음성/비음성 분류는 통계적 모델을 이용한 분류-기반 방법을 사용한다. 검출기에서 실시간 적응화를 위해 우도-기반의 특징 벡터에 대한 차원 축소 방법을 제안한다. 이 방법은 음성/비음성 클래스에 대한 가우시안 확률 밀도 함수에 의한 비선형적 우도값을 새로운 특징으로 취하는 방법이다. 음성/비음성 결정은 우도비 검증(Likelihood Ratio Test)의 방법을 이용하며, LDA(Linear Discriminant Analys)에 의한 축소 결과와 성능을 비교한다. 실험 결과 제안된 차원 축소 방법을 통하여 2차원으로 축소된 특징 벡터가 고차원에서의 결과와 대등함을 확인하였다.

  • PDF

A Study on DC side Model of Current Source type Active Power Filters (전류원형 능동 전력 필터의 직류측 모델에 관한 연구)

  • Han, Hak-Guhn;Park, In-Gyu;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.180-185
    • /
    • 1989
  • In the current source type active power filter, the DC current source is implemented using an inductor with large inductance by maintaining the inductor current constantly. In this case, to compensate the loss of the switching devices of the power converter and the inductor, some real power should be supplied to the filter from the source. This process is analyzed through the equivalent circuit which expresses the loss of the switching devices and the inductor with the equivalent resistor R. This work discusses the validation of this DC side equivalent circuit and points out the problems, through the experiments using the experimental active power filter with 220V, 10KVA ratings, and suggests a more accurate equivalent circuit which puts the saturation voltage of the power transistors and the threshold voltage of the diodes into consideration.

  • PDF

Study of Dynamic Characteristics of an UPFC Switching-Level Model (UPFC의 스위칭레벨 상세 모의 및 동적 특성 고찰)

  • Won, D.J.;Kim, S.H.;Han, H.G.;Lee, S.K.;Moon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1287-1289
    • /
    • 1999
  • The UPFC(Unified Power Flow Controller) controls the magnitude and phase of the series injected voltage to exchange the real and reactive power with transmission line. The UPFC consists of two inverters connected together through the DC link capacitor. This paper describes the detailed UPFC switching-level model. PWM (Pulse Width Modulation) method is chosen to operate the inverters. Automatic voltage control mode and automatic power flow control mode is selected to control the UPFC. EMTP simulation is offered to obtain the basic operation characteristics of the UPFC and the dynamic characteristics of the UPFC is studied in detail.

  • PDF

Dynamic Model Study for the Analysis of the STATCOM Characteristics (STATCOM의 특성해석을 위한 동적모델 고찰)

  • Kim, S.H.;Won, D.J.;Han, H.G.;Lee, S.K.;Moon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1039-1041
    • /
    • 1999
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. [2] STATCOM is a voltage source inverter(VSI) based static VAr compensator with only small capacitors on the do side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. [1] This paper compares the PAM STATCOM with PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods was presented.

  • PDF

The Dynamic Characteristics Analysis of the STATCOM According to the Realization of the STATCOM Output Voltage (STATCOM의 출력전압 구현방식에 따른 동특성 해석)

  • Kim, Seon-Ho;Won, Dong-Jun;Han, Hak-Geun;Lee, Song-Geun;Mun, Seung-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.323-331
    • /
    • 2000
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. The STATCOM is a voltage source inverter(VSI) based on the static VAr compensator with only small capacitors on the dc side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. This paper compared the PAM STATCOM with the PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods is presented.

  • PDF

  ( )

  • 박철희;유재우
    • Communications of the Korean Institute of Information Scientists and Engineers
    • /
    • v.5 no.2
    • /
    • pp.61-84
    • /
    • 1987
  • This paper deals with actual constructions of programs for experiments in several parsers based on the theoritical results of others that represent on of the most fruiful contributions in computer science. Specifically the report deals with (1) a general computer representation of grammar (2) a precedence parser generator, (3) a LL (1) parser generator, (4) a practical SLR (1)/LALR (1) parser generator.

Attitude Control of Model Helicopter using the LQR Controller (최적 LQR 제어기를 이용한 모형 헬리콥터의 자세 제어)

  • Han, Hak-Sic;Jeong, Sang-Chul;Kim, Gwan-Hyung;An, Young-Joo;Lee, Hyung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2171-2175
    • /
    • 2002
  • Helicopter dynamics are plenty of nonlinearity. A complete mathematical model including propeller dynamics and fortes generated by the propellers is very difficult to obtain. So the method used to design to design a controller is a parameter estimation. Design controller based on variable structure system. This paper deals with LQR control technique to control efficiently, its elevation angle and azimuth one. The purpose of the experiment is to design a controller allows to use a desired elevation angle and azimuth ones. The system model has a helicopter model with 2-degree-of freedom. The simulation results were verified usefulness of controller.

  • PDF

A Study on Switched Reluctance Motor Driving using Commutator (정류자를 이용한 스위치드 릴럭턴스 전동기의 구동에 관한 연구)

  • Won, Sung-Hong;Han, Hak-Guhn;Jung, In-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.67-74
    • /
    • 2012
  • This paper presents the novel design and implementation of a switched reluctance motor with commutator. Unlike typical switched reluctance motor, this motor doesn't require semi-conductor devices and inverter circuits for driving. Instead, the brushes and commutator can make rotating field for driving the switched reluctance motor. Moreover, because this motor has no magnet, the total cost for manufacturing the motor is very cheap. In order to verify the usability of the proposed motor, the authors manufactured the prototype motor, and showed the torque-speed curve of the motor.