• Title/Summary/Keyword: 한중

Search Result 1,070, Processing Time 0.032 seconds

Effect of working time on the film thickness of dental resin cements (레진 시멘트의 혼합 후 시간에 따른 피막도의 변화)

  • Yi, Yu-Seung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.325-329
    • /
    • 2015
  • Purpose: The aim of this study was to compare the film thicknesses of several resin cements as a function of time after mixing and to examine the effect of working time on the film thicknesses. Materials and methods: The film thickness (${\mu}m$) of 4 resin cements (n=10), 1 composite resin (Panavia F 2.0), 3 self-adhesive resin (Clearfil SA luting, Zirconite, RelyX U200) cements was measured at 20-second intervals after mixing of the cements up to 200 seconds under a load of 50 N. Linear regression was fitted to verify the effect of working time on the film thickness of each cement. Data were compared to the working time recommended by manufacturers using Wilcoxon test ($\alpha$=.05). Results: All of the materials showed a positive linear correlation between the film thickness and working time. There was no statistically significant difference between the working time based on our results and the values recommended by the manufacturers even though there was a discrepancy between those two values. Conclusion: The film thickness of resin cements could increase with the increase of working time. Working time to meet the ISO standard of $50-{\mu}m$ maximum film thickness could be different from the manufacturer's recommended value.

Changes in Benthic Macroinvertebrate Community Before and After Rainy Season in Mountain Valley with Erosion Control Dam (사방댐이 설치된 산지계곡의 장마 전·후 저서성 대형무척추동물 군집변화)

  • An, Chae-Hui;Han, Jung-Soo;Choi, Jun-Kil;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.2
    • /
    • pp.121-129
    • /
    • 2020
  • This study investigated the change of benthic macroinvertebrates community due to erosion control dams installed in Wonju, Gangwon by comparing the data before and after a rainy season. It selected a closed-type erosion control dam (boulder stone), an open-type erosion control dam (buttress), and a control area and surveyed two upstream points and two downstream points four times between March and September 2019. The flow velocity mostly increased in the closed-type, open-type, and control areas but decreased in St. 3 after the rainy season. The number of benthic macroinvertebrates species and their populations mostly decreased after the rainy season, and the rate of decrease in the populations in the open-type and control areas were more similar than the closed-type area. Species and populations of the EPT groups mostly decreased after the rainy season. A result of the similarity analysis showed that the closed-type and open-type areas were separated by 38.4% with the control area before the rainy season, but the open-type and control areas were separated by 51.3% with the closed-type area after the rainy season. A result of the principal components analysis (PCA) based on axis 1 showed that the closed-type area had a positive value before and after the rainy season, and the open-type and control areas had a negative value before and after the rainy season. The open-type area was more correlated with the control area than the close type. The analysis of the EPT groups showed the distribution of Ephemeroptera in the closed-type area and Trichoptera in the open-type and control areas. The result of this study shows that the installation of erosion control dam can cause changes in benthic macroinvertebrates community and that the open-type area had a smaller difference community difference from the control area after the rainy season than the closed-type area.

The Effect of Water Conveyance of Boryeong Dam on Structural Changes of Benthic Macroinvertebrates Community (보령댐 도수가 저서성 대형무척추동물 군집구조 변화에 미치는 영향)

  • An, Chae-Hui;Han, Jung-Soo;Choi, Jun-Kil;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.4
    • /
    • pp.381-391
    • /
    • 2018
  • The purpose of this study is to investigate the influence of artificial disturbances occurring during water conveyance frequency on benthic macro-invertebrate by comparing and analyzing data before and after the construction of Boryeong dam in Boryeong-si, Chungcheongnam-do. We conducted the survey eight times in four points from April 2016 to September 2017. A total of 13,447 individuals from 125 species, 70 families, 19 orders, 7 classes, and 4 phyla were collected. The result of the community analysis showed that the dominant index was 0.55 (${\pm}0.07$) to 0.47 (${\pm}0.08$), diversity index was 2.06 (${\pm}0.26$) to 2.23 (${\pm}0.28$), evenness index was 0.69 (${\pm}0.05$) to 0.70 (${\pm}0.04$), and richness index was 3.43 (${\pm}0.72$) to 4.03 (${\pm}0.91$). After conveyance, the dominance decreased while the diversity, evenness, and richness increased. The result of the functional group analysis showed the portion of scrapers, filtering-collectors increased while that of shredders, gathering-collectors decreased in the functional feeding group and that the proportion of climbers and clingers increased while that of burrowers and sprawlers decreased in the habitat orientation group. The result of analysis of community stability showed that St. 1 and St. 2 decreased resistance and resilience after conveyance and new species appeared in the III characteristics group while St. 3 and St. 4 did not show much difference. The result of multidimensional scaling analysis showed that the variation of similarity was the highest at St. 1 after conveyance, and the variation of similarity at St. 4 was the lowest.

A study on the interrelation of influential factors in organizational conflict and organizational commitment (병원종사자의 조직갈등 및 조직몰입에 영향을 미치는 요인에 관한 연구)

  • Kim, Young-Hoon;Kim, Han-Joong;Cho, Woo-Hyun;Lee, Hae-Jong;Park, Chong-Yon;Lee, Sun-Hee
    • Korea Journal of Hospital Management
    • /
    • v.7 no.1
    • /
    • pp.41-63
    • /
    • 2002
  • The purpose of this study is to analyze the interrelation of influential factors in organizational conflict and organizational commitment. The data for this study were collected through a self-administered survey with a structured Questionnaire to 1,167 subjects from several nursing staff members, administration staff members and medical technicians of six hospitals. In this analysis frequency test, t-test, ANOVA, hierarchical multiple regression and structural equation model were used. The main findings of this study are as follows. 1. Factors which influence organizational conflict were analyzed. The type of occupation and the year of service were socio-demographic variables which influenced organizational conflict positively. Adjusted R square was 0.03. Perceptions on organizational structure and organizational culture were analyzed with two- level variables that were added. The findings were as follows. Adjusted R square increased to 0.25. The year of service, internal process culture and rational goal culture were positive variables. The design of organizational structure, human relations culture and open system culture were negative variables. 2. Variables which influence organizational commitment were analyzed. Age and the year of service were positive variables, while academic background based on high school education was a negative variable. Adjusted R square was 0.16. Perceptions on organizational structure and organizational culture were analyzed with two-level variables that were added. The findings were as follows. The characteristics of organizational structure, human relations culture and organizational culture were positive variables. Adjusted R square increased to 0.55. The variables of organizational conflict were added in 3 steps. Findings were as follows. The variables of hierarchical conflict showed negative influence and were included in two-level influential variables. Adjusted R square increased to 0.56. 3. Structural equation model was analyzed in order to examine the relation between organizational structure and the variables of organizational culture, organizational conflict and organizational commitment. Thirteen path coefficients out of seventeen path coefficients were significant. Age had negative influence on organizational conflict and positive influence on organizational commitment. The year of service had positive influence on organizational conflict and organizational commitment. The design of organizational structure, human relations culture and open system culture had negative influence on organizational. conflict. They had positive influence on organizational commitment. Internal process culture and rational goal culture had positive influence on organizational conflict. Organizational conflict had negative influence on organizational commitment. The squared multiple correlation of this model was 25.1% in organizational conflict and 52.7% in organizational commitment. The conclusion of this study is as follows. Factors in organizational structure and organizational culture, rather than socio-demographic factors, had a stronger influence on the organizational conflict and organizational commitment of hospitals. In order to decrease organizational conflict, to increase organizational commitment and to maximize the effectiveness of hospital management, it is necessary to understand the overall relation between organizational structure, organizational culture, organizational conflict and organizational commitment, with the effort of improving personalized factors and individual factors of organization management.

  • PDF

Accuracy Analysis of FKP for Public Surveying and Cadastral Resurvey (공공측량 및 지적재조사 사업 적용을 위한 FKP 정밀도 분석)

  • Park, Jin Sol;Han, Joong-Hee;Kwon, Jay Hyoun;Shin, Han Sup
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.23-24
    • /
    • 2014
  • NGII (National Geographic Information Institute) has been providing VRS (Virtual Reference Station) service so that could determine precise positioning in real time since 2007. However, since the VRS service has to maintain the connected status with VRS server, the number of users who can use VRS service are limited by capacity of VRS server. To solve this problem, NGII has been providing FKP (Virtual Reference Station) service using one way telecommunication from November 1, 2012. Therefore, it is predicted that the usage of FKP service will increase in public surveying and cadastral resurveying in the future. However, the studies with respect to analysis of FKP precision for applying to public surveying and cadastral resurveying is not conducted enough. In this study, to analyse the application possibility of FKP on the public surveying and cadastral resurveying, the two kind analysis were performed. First is the analysis of accuracy according to the configuration of reference station of FKP and VRS. One is consisted of same reference stations, another is consisted of different reference stations. Second is the accuracy anlalysis of horizontal and vertical positioning acquiring VRS and FKP data in various measurement environment based on VRS regulation. Result of first study, Positioning accuracy according to the configuration of the reference stations satisfies related regulation. However, accuracy of FKP in case of different reference stations is worse than in case of same reference stations.. The result of second test shows that the horizontal precision of FKP and VRS in good measurement environment satisfy the allowed precision. However, in some case, horizontal precision of FKP and VRS in poor measurement environment exceed the allowed precision. In addition, the number of exceeding the allowed precision in the FKP is more than the VRS. The vertical precision of the VRS satisfy related work provision. In conclusion, the result of this study shows that the FKP only in open area should be used for public survey and cadastral resurvey. Therefore the additional studies with respect to the improvement of FKP precision should be conducted.

In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements (치과용 레진 시멘트의 중합 수축률 특성에 관한 연구)

  • Kim, Tae-Hoon;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: The shrinkage of dental resin cement may cause several clinical problems such as distortion that may jeopardize the accurate fit to the prepared tooth and internal stress within the restorations. It is important to know the polymerization shrinkage-strain of dental resin cement to reduce clinical complications. The purpose of this study was to investigate the polymerization shrinkage-strain kinetics of six commercially available dental resin cements. Material and methods: Three self-cure resin cements (Fujicem, Superbond, M-bond) and three dual-cure resin cements (Maxcem, Panavia-F, Variolink II) were investigated. Time dependent polymerization shrinkage-strain kinetics of the materials were measured by the Bonded-disk method as a function of time at $23^{\circ}C$, with values particularly noted at 1, 5, 10, 30, 60, 120 min after mixing. Five recordings were taken for each materials. The data were analyzed with one-way ANOVA and Scheffe post hoc test at the significance level of 0.05. Results: Polymerization shrinkage-strain values were 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90% for Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II, respectively at 120 minutes after the start of mixing. Panavia F exhibited maximum polymerization shrinkage-strain values, but Superbond showed minimum polymerization shrinkage-strain values among the investigated materials (P < .05). There was no significant differences of shrinkage-strain value between Maxcem and M bond at 120 minutes after the start of mixing (P > .05). Most shrinkage of the resin cement materials investigated occurred in the first 30 minutes after the start of mixing. Conclusion: The onset of polymerization shrinkage of self-cure resin cements was slower than that of dual-cure resin cements after mixing, but the net shrinkage strain values of self-cure resin cements was higher than that of dual-cure resin cements at 120 minutes after mixing. Most shrinkage of the dental resin cements occurred in the first 30 minutes after mixing.

Influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva (인공타액에 노출되었던 금속도재관의 재소성이 색조와 표면기포 형성에 미치는 영향에 관한 연구)

  • Park, Ji-Hyun;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.161-167
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva. Materials and methods: Thirty disk-shaped specimens were made in 10 mm diameter with 0.5 mm metal core thickness and 1 mm ceramic thickness. A spectroradiometer was used to determine the CIE Lab coordinates. The number and size of surface bubble were observed with a stereomicroscope. After the exposure to artificial saliva for 7 days, re-firing was performed at glazing temperature. After re-firing, the CIE Lab were calculated, and the number and size of surface bubble were observed again. The change in shade was expressed with ${\Delta}E$. Statistical analysis was done with paired t-test for the change in the number of surface bubble and student t-test for the change in the size of surface bubble (${\alpha$}=0.05). Results: Shade difference was calculated 2.14 ${\Delta}E$ units. The mean number of surface bubble was $1.33{\pm}1.49$ before re-firing, $3.27{\pm}2.90$ after re-firing. After re-firing, the number of surface bubble was significantly increased (P<.05). The mean size of surface bubble was $81.97{\pm}32.03\;{\mu}m$ before re-firing, $142.94{\pm}47.40\;{\mu}m$ after re-firing. After re-firing, the size of surface bubble was significantly increased (P<.05). Conclusion: Shade change after re-firing was perceptible (${\Delta}E$ < 2.0) and clinically acceptable (${\Delta}E$ < 3.7). The number and size of surface bubble was significantly increased after re-firing. Further investigation to decrease the surface bubble on the extra oral repair of metal-ceramic crown, will be needed in future study.

Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model (골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구)

  • Kwon, Taek-Ka;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.128-137
    • /
    • 2011
  • Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.

Effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia (시편 제작 방법이 지르코니아 코어와 비니어링 세라믹의 미세 인장결합강도에 미치는 영향)

  • Kim, Ki-Yeon;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.114-119
    • /
    • 2011
  • The aim of this study was to investigate effect of specimen preparation method on the microtensile bond strength of veneering ceramic to zirconia core. Materials and methods: Cylindrical Lava zirconia block (3M ESPE, Seefeld, Germany) was cut into discs using a diamond disc. After sintering, the core specimens were placed in an adjustable mold and veneered with Lava ceram (3M ESPE, Seefeld, Germany). The disc shaped specimen of group 1 was cut into microbars ($1{\times}1{\times}7\;mm^3$) using a low speed diamond disc under water cooling (n = 15). The specimen of group 2 was cut into microbars ($1.2{\times}1.2{\times}7\;mm^3$) in the same way. Whereafter the microbars were trimmed ($1{\times}1{\times}7\;mm^3$) using a thick diamond disc under water cooling (n = 15). The microtensile bond strength was tested in a microtensile tester (Instron 8848, $Instron^{(R)}$ Co., Norwood, USA). Fractured microtensile specimens were analyzed under a stereomicroscope (MZ6, Leica Microsystems GmbH, Wetzlar, Germany) at magnification ${\times}30$. Results: The microtensile bond strength of group 1 ($28.8{\pm}7.0\;MPa$) was significantly higher than group 2 ($11.0{\pm}33\;MPa$) (P=.00). Conclusion: It appears advisable to avoid the trimming action, especially high strength ceramic specimens.