• Title/Summary/Keyword: 한상기

Search Result 525, Processing Time 0.027 seconds

프렌차이점에서 사용되는 튀김류의 산패도 및 트랜스지방의 함량 비교

  • Kim, Yeong-Seong
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2005.12a
    • /
    • pp.76-97
    • /
    • 2005
  • As the recent change of multiformity and taste in clination in eating habit culture is yearly in creasing foods used oil and fats. Because the frying food is especially important snack , it's safty is very essential. In order to know the safty and harmfulness of frying oil and fats. The 20 kinds samples were purchased chicken fried food shops around the north of seoul and kyunggi. The acid value, iodine value, peroxide value, TBA value, fatty acid, carbonyl value, and smoke point of deep fat fried oils were analyzed. Results of analyzed, A company of deep fat frying oil showed stability state and C company and B company of deep fat frying oil is acidification to turned. But D company of deep fat frying oil showed quite a bit acidification progressived of used hydrogenated oil.

  • PDF

Antibiotics Susceptability of Streptococcus pneumoniae Isolated from Pharynx in Healthy Korean Children and Choice of Proper Empirical Oral Antibiotics Using Pharmacokinetics/Pharmacodynamics Model (국내의 소아에서 분리된 폐구균의 항생제 감수성 양상 및 약력동학 모델을 이용한 적절한 항생제의 선택)

  • Paik, Ji Yeun;Choi, Jae Hong;Cho, Eun Young;Oh, Chi Eun;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.109-116
    • /
    • 2011
  • Purpose : Pneumococcus is one of the most important causes of invasive infection through the childhood period. In January 2008, the Clinical and Laboratory Standards Institute (CLSI) published revised penicillin breakpoints for Streptococcus pneumoniae and penicillin susceptibility rates of S. pneumoniae increased in Korea. This study was performed to determine the probability of oral amoxicillin for the empirical treatment achieving bactericidal exposure against pneumococcus using pharmacodynamics model. Methods : Twenty-three isolates of pneumococci were subjected to determine minimum inhibitory concentration (MIC) for ${\beta}$-lactams and macrolide. For the ${\beta}$-lactams, exposure of fT >MIC (time that free drug concentrations remain above the MIC) for 50% of the administration interval have determined the probability of target attainment (PTA), and regimens that had a PTA >90% were considered optimal. An analysis was performed by applying MIC of 23 isolates to a 5000-patient Monte Carlo simulation model. Results : Among 23 isolates from healthy children, 7 (30.4%) isolates were MIC ${\leq}$1.0 ${\mu}g$/mL and 19 (82.6%) were MIC ${\leq}$2 ${\mu}g$/mL for amoxicillin. Amoxicillin 40 mg/kg/day achieved PTA >90% at MIC ${\leq}$1.0 ${\mu}g$/mL but PTA decreased to 52% at MIC 2 ${\mu}g$/mL, whereas amoxicillin 90 mg/kg/day can predict 97% of PTA at MIC 2 ${\mu}g$/mL. Overall, oral amoxicillin 90 mg/ kg/day for the empirical treatment against pneumococcus can expect more successful response in Korean children. Conclusion : Considering the resistantce pattern of pneumococci in Korean children, we estimate that oral amoxicillin 90 mg/kg/day will provide a pharmacodynamic advantage for the empirical treatment against pneumococcus. And low dose amoxicillin or macrolide are expected to have higher chance of treatment failure than high dose oral amoxicillin.

Effects of Boron Application on the Forage Traits in the Pure and Mixed Cultures of Orchardgrass and White Clover - IV. Changes in the contents of micronutrients(Fe, Mn, Zn, Cu, and B) in forages - (Orchardgrass 및 White Clover의 단파 및 혼파재배에서 붕소의 시용이 목초의 여러 특성에 미치는 영향 - IV. 목초 중 미량요소(Fe, Mn, Cu, Zn과 B)의 함량 변화 -)

  • Jung, Yeun-Kyu
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.3
    • /
    • pp.179-186
    • /
    • 2003
  • This pot experiment was conducted to find out the effects of boron application( $B_{0}$ ) ; control, B$_1$; 0.2, $B_2$; 2.0, $B_3$; 6.0, $B_4$; 15.0 boron me/pot) on the forage performance of pure and mixed cultures of orchardgrass and white clover. The fourth part was concerned with the changes in the contents of B, Fe, Mn, Cu, and Zn in forages. The results obtained are summarized as follows: 1. The boron(B) contents of both forages and their differences among the B treatments generally decreased according to the cutting order. The B contents of white clover were somewhat lower in the $B_{0}$ than in the $B_2$. However, the differences in the yields between $B_{0}$ and $B_2$ were relatively great. It was probably caused by the latent B-deficiency in the $B_{0}$. Compared with white clover, the B contents of orchardgrass had relatively great differences between the $B_{0}$ and B$_2$, but both yields tended to be similar. 2. The contents of Fe, Mn, Cu, and Zn in both forages were generally different according to the forage species, whether it was a pure or mixed cultures, and additional fertilization. The effects of B application on their contents were different according to the micronutrients and above factors. 3. The Fe contents of white clover were lower in the $B_{0}$ and $B_4$ than in the$ B_2$. It tended to be related to the weak growth of roots and low yields in the $B_{0}$ and $B_2$. However, there were not consistent in the changes of contents of Mn, Cu, and Zn by the rates of B application. 4. The effects of B application on the total ion concentrations of Fe, Mn, Cu, and Zn were not consistent in both forages. However, the concentrations were generally affected by the changes in the contents of Mn and Zn. The concentrations of white clover were higher in a pure than in mixed culture.

A Study of Iljiam Tea Garden of Daeheung-sa at Mt. Dooryun - Focusing on the Comparison between Poetry and Current State - (두륜산 대흥사 일지암 다정(茶庭)의 일고찰(一考察) - 시문과 현황 비교를 중심으로 -)

  • Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.97-110
    • /
    • 2012
  • This study aimed at considering the original shape of Iljiam Tea Garden at Mt. Daedun. In order to accomplish our goal, we tried to strengthen the authenticity of construction of Iljiam by comparing its space structure depicted in the poetry of Choeui(艸衣) the monk with its current restored state. According to the clues and situation in the poetry along with symbolic words like 'Choeui' and 'Ilji(一枝)', Iljiam seemed to be a tea garden with elegant and celestial beauties, and with a nice view where Choeui the famous monk searched for the highest state of enlightenment by enjoying and living in nature. When we compared the plural aspects of Iljiam like Dacheon(茶泉), Dajo, Mulhwak, Darim(茶林), Chaewon(菜園), and Yeonji(蓮池) with those of Dasan Tea Garden[茶山草堂], we could see that the basic components of tea-culture space of both gardens are the same, showing the organizational principle of the top and bottom area to stress reading and studying. When it is restored, the authenticity of Iljiam should be pursued by linking spatial, historical, and landscaping characteristics as the space of which Choeui the monk carried out Zen meditation and mastered tea. However, the recent grand scale Buddhist business like the expansion of access road and construction of Buddhist sanctuary and Seolimdang became the biggest threat to the authenticity. Especially, it was emphasized many times in various poetry that the view from Iljiam and its surroundings is extraordinary, so it is critical to get rid of obstacles to the view from Iljiam and its surroundings in order to restore Iljiam as its genuine form. The current Iljiam should be re-made because it is like a leaf-roofed garden, not like a hermitage. However, the opinion that Jawoohongryeon-sa(紫芋紅蓮社) is somewhat a Taoistic and Taoist hermit space with a special shape adopted the pattern of building of the Joseon period rather than a Buddhist building can be accepted as long as other convincing historical evidences are found out, considering the ideology of uniting Confucianism and Buddhism and the spirit of Taoist hermit found out from poetry of Choeui and his friends. In conclusion, the restoration of Iljiam in 1979 was carried out to restore the place of Iljiam rather than to restore the originality of Iljiam by combining and referring domestic cases of tea gardens. However, there is not much material for restoration even though the main frame of Iljiam was distorted. Nevertheless, the top and bottom ponds should be constructed as a rectangle shape. In addition, it can be improved much in terms of plants and trees. It is necessary to restore bamboo forest, which was razed in order to make a tea plantation around Seolimdang, to set vines of arbors above the upper limbs, to plant pine trees and willow trees inside of the garden, and to put Dajeolgu under the corner of the eaves. Especially, the bamboo forest emphasized in poetry and took care of by Choeui himself should be restored inside of the garden.

A Felling Work Study for Thinning Japanese Larch (일본잎갈나무 간벌림(間伐林) 벌목작업(伐木作業) 연구(硏究))

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.73 no.1
    • /
    • pp.14-20
    • /
    • 1986
  • The processing times of the works, chainsaw felling, axe trimming and hand skidding to the corridor, by one-man-work method per single pole timber were investigated in the thinning young Japanese larch stand at the Training Forests of the Forest Work Tranining Center in Kangwon-do. The works were performed by a skilled worker with the craftman qualification and 69 trees were cut. Time was checked at intervals of 25/100 minute by the multimoment method and the worker's efficiency was evaluated for every cycle. Total working time was 8.11 hours of which 90% was for thinning work and 10% for cleaning work. Of the total working hours, 82.7% was net working time, 12.3% was general working time and 4.9% was non-valuated time. Of the net working time, 5.9hours, for only thinning, 20.9% was spent on moving to the feeling tree, 27.1% was spent on felling, 40.5% was spent on trimming and 11.5% was spent on skidding to corridor. Net chainsaw operating time was 0.94 hour which included 0.2 hour for cleaning work. Of the net chainsaw operating time, 0.94 hour, 66% was operating time and 34% was idle running time. The basic and general working times by DBH classes with application of 130% worker's efficiency calculated from regression equations were shown in table 1. For better practical using of this table, the simplified proposal was given in table 2.

  • PDF

Detection of Spoilage Odors in Beef Using R-index and Pseudomonas Growth during Storage (쇠고기의 저장 중 R-index에 의한 부패취 발생시점과 Pseudomonas의 증식과의 비교 분석)

  • Byeon, Ko Eun;Park, Han Jo;An, Soo Rim;Hong, Kwang Won;Min, Sang Gi;Chung, Ku Young;Won, Kee Hoon;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.117-121
    • /
    • 2009
  • Detection of spoilage odors from beef during storage was investigated using sensory evaluation with R-index, and microbial assay for Pseudomonas. Beef samples were tested to measure the flavor changes, which were converted to R-index, and the Pseudomonas levels during storage. There was a steep rise in R-index until 36 hr after storage at 25$^{\circ}C$, and then a gentle rise from 48 hr, whereas, there was a steady rise in R-index in the whole range of storage at 5$^{\circ}C$. Detection time of spoilage odors according to R-index was statistically analyzed at $\alpha$=5% to be at 30.92${\pm}$3.47 hr and 169.80${\pm}$11.27 hr for 25 and 5$^{\circ}C$ storage, respectively, and analyzed at $\alpha$=1% to be 34.80${\pm}$4.01 and 176.41${\pm}$9.89 hr for 25 and 5$^{\circ}C$ storage, respectively. At the detection times of spoilage odors, the Pseudomonas levels were found to be almost the same, but less than 6-7 log CFU/g generally known as a standard level at occurrence of spoilage odors in beef. This indicated that some other factors than the Pseudomonas reactions could be associated with generation of spoilage odors.

A Comparison Study of Alkalinity and Total Carbon Measurements in $CO_2$-rich Water (탄산수의 알칼리도 및 총 탄소 측정방법 비교 연구)

  • Jo, Min-Ki;Chae, Gi-Tak;Koh, Dong-Chan;Yu, Yong-Jae;Choi, Byoung-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.1-13
    • /
    • 2009
  • Alkalinity and total carbon contents were measured by acid neutralizing titration (ANT), back titration (BT), gravitational weighing (GW), non-dispersive infrared-total carbon (NDIR-TC) methods for assessing precision and accuracy of alkalinity and total carbon concentration in $CO_2$-rich water. Artificial $CO_2$-rich water(ACW: pH 6.3, alkalinity 68.8 meq/L, $HCO_3^-$ 2,235 mg/L) was used for comparing the measurements. When alkalinity measured in 0 hr, percent errors of all measurement were 0~12% and coefficient of variation were less than 4%. As the result of post-hoc analysis after repeated measure analysis of variance (RM-AMOVA), the differences between the pair of methods were not significant (within confidence level of 95%), which indicates that the alkalinity measured by any method could be accurate and precise when it measured just in time of sampling. In addition, alkalinity measured by ANT and NDIR-TC were not change after 24 and 48 hours open to atmosphere, which can be explained by conservative nature of alkalinity although $CO_2$ degas from ACW. On the other hand, alkalinity measured by BT and GW increased after 24 and 48 hours open to atmosphere, which was caused by relatively high concentration of measured total carbon and increasing pH. The comparison between geochemical modeling of $CO_2$ degassing and observed data showed that pH of observed ACW was higher than calculated pH. This can be happen when degassed $CO_2$ does not come out from the solution and/or exist in solution as $CO_{2(g)}$ bubble. In that case, $CO_{2(g)}$ bubble doesn't affect the pH and alkalinity. Thus alkalinity measured by ANT and NDIR-TC could not detect the $CO_2$ bubble although measured alkalinity was similar to the calculated alkalinity. Moreover, total carbon measured by ANT and NDIR-TC could be underestimated. Consequently, it is necessary to compare the alkalinity and total carbon data from various kind of methods and interpret very carefully. This study provide technical information of measurement of dissolve $CO_2$ from $CO_2$-rich water which could be natural analogue of geologic sequestration of $CO_2$.

Epidemiology and Clinical Characteristics of Parainfluenza Virus Type 4 in Korean Children: a Single Center Study, 2015-2017 (소아에서 파라인플루엔자 바이러스 4형의 역학 및 임상 양상에 대한 단일기관 연구: 2015-2017)

  • Sohn, Young Joo;Choi, Youn Young;Yun, Ki Wook;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.3
    • /
    • pp.156-164
    • /
    • 2018
  • Purpose: We aimed to identify the epidemiology and the clinical characteristics of human parainfluenza virus type 4 (HPIV-4) infection compared to HPIVs 1-3 infections in Korean children. Methods: We reviewed medical records of children with HPIV infection who visited Seoul National University Children's Hospital from 2015 to 2017. Detection of respiratory viruses was performed using real time-polymerase chain reaction (rt-PCR), which could differentiate HPIVs 1-4. Diagnosis was classified as a febrile illness, upper respiratory tract infection (URI), croup, bronchiolitis, or pneumonia. The epidemiology, demographic features, and clinical characteristics among HPIV types were compared. The clinical data were analyzed only for the previously healthy children. Results: Of the 472 children diagnosed with HPIV infection, 108 (22.9%) were previously healthy: 24 (22.2%), 19 (17.6%), 39 (36.1%), and 26 (24.1%) in HPIV types 1, 2, 3, and 4, respectively. The median age of children with HPIV-4 infection was 11 (0-195) months: the proportion of children aged < 2 years and 2 to < 5 years were 65.4% and 19.2%, respectively. Clinical diagnoses of HPIV-4 infection were bronchiolitis (38.5%), pneumonia (30.8%), and URI (30.8%). Croup was the most prevalent in HPIV-2 (21.1%) and none in HPIV-4 infection (P=0.026). Hospital admission rates among HPIV types were not significantly different (P>0.05). Conclusions: We observed seasonal peak of HPIV-4 infection in 2015 and 2017. HPIV-4 was a common respiratory pathogen causing lower respiratory tract infection in hospitalized children.

Carbon Reduction by and Quantitative Models for Landscape Tree Species in Southern Region - For Camellia japonica, Lagerstroemia indica, and Quercus myrsinaefolia - (남부지방 조경수종의 탄소저감과 계량모델 - 동백나무, 배롱나무 및 가시나무를 대상으로 -)

  • Jo, Hyun-Kil;Kil, Sung-Ho;Park, Hye-Mi;Kim, Jin-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.3
    • /
    • pp.31-38
    • /
    • 2019
  • This study quantified, through a direct harvesting method, storage and annual uptake of carbon from open-grown trees for three landscape tree species frequently planted in the southern region of Korea, and developed quantitative models to easily estimate the carbon reduction by tree growth for each species. The tree species for the study included Camellia japonica, Lagerstroemia indica, and Quercus myrsinaefolia, for which no information on carbon storage and uptake was available. Ten tree individuals for each species (a total of 30 individuals) were sampled considering various stem diameter sizes at given intervals. The study measured biomass for each part of the sample trees to quantify the total carbon storage per tree. Annual carbon uptake per tree was computed by analyzing the radial growth rates of the stem samples at breast height or ground level. Quantitative models were developed using stem diameter as an independent variable to easily calculate storage and annual uptake of carbon per tree for study species. All the quantitative models showed high fitness with $r^2$ values of 0.94-0.98. The storage and annual uptake of carbon from a Q. myrsinaefolia tree with dbh of 10 cm were 24.0 kg and 4.5 kg/yr, respectively. A C. japonica tree and L. indica tree with dg of 10 cm stored 11.2 kg and 8.1 kg of carbon and annually sequestered 2.6 kg and 1.2 kg, respectively. The above-mentioned carbon storage equaled the amount of carbon emitted from the gasoline consumption of about 42 L for Q. myrsinaefolia, 20 L for C. japonica, and 14 L for L. indica. A tree with the diameter size of 10 cm annually offset carbon emissions from gasoline use of approximately 8 L for Q. myrsinaefolia, 5 L for C. japonica, and 2 L for L. indica. The study pioneers in quantifying biomass and carbon reduction for the landscape tree species in the southern region despite difficulties in direct cutting and root digging of the planted trees.

Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364 (IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구)

  • Kim, Soon-Sik;Han, Byeong-Gill;Lee, Hu-Dong;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.599-609
    • /
    • 2021
  • A novel grounding system, which is presented in IEC 60364, has been adopted since 2021. A safety evaluation for the human body on the grounding system is required due to the various characteristics of the touch voltage and current passing when the human body experiences an electric shock. The Korea Electrical Safety Corporation (KESCO) and Korea Electric Association (KEA) have been conducting a safety technical education on the grounding system. On the other hand, it is difficult to instruct the electrical safety manager because of a lack of safety evaluations for the test equipment on the grounding system. Therefore, this paper modeled and implemented a test device for a safety evaluation depending on the grounding system of IEC 60364. Namely, this paper presents the modeling of the test device for a safety evaluation using PSCAD/EMTDC S/W, which is composed of an AC grid section, s test device section on the grounding system, and a sub-device section. This paper implemented a test device for safety evaluation, which consisted of an AC grid section, TT grounding system section, TN-S grounding system section, and monitoring section. From the simulation and test results with the safety characteristics of the human body in the TT and TN-S grounding system, when the fault impedances are 0[Ω], 10[Ω], and 100[Ω], the currents passing through the human body in the TT grounding system are 104[mA], 87.4[mA], and 35.5[mA], respectively. The corresponding currents in the TN-S grounding system are 54.9[mA], 4.1[mA], and 0.4[mA], respectively. Based on the results, the protection performance for an electric shock to the human body in the TN-S system is better than the TT system. This can be improved when the existing grounding system is changed from the TT system to the TN-S system.