• Title/Summary/Keyword: 한류특성

Search Result 293, Processing Time 0.028 seconds

Effect analysis study of "Korean Wave" on Chinese entertainment shows (중국 예능 방송의 한류 영향 분석 연구)

  • Han, Ting Ting;Choi, Chul Young
    • Cartoon and Animation Studies
    • /
    • s.35
    • /
    • pp.313-327
    • /
    • 2014
  • Starting with a Korean soap opera in the year 1993, entertainment industry of South Korea such as K-pop, soap operas, Korean celebrities has been introduced and spread throughout China. The new word 'Korean wave' was coined by fans of Korean entertainment culture at this time, and passion on the subject gradually expanded from soap operas to entertainment programs in the market of China. It is necessary to analyze the current situation that Korean entertainment programs gaining tremendous popularity on the entertainment field in China and research on ways to cope with the fierce competition and to change to survive from it. Nowadays Korea has its own unique attribute with its national traits after years of mere imitative adaptation from broadcast program of Japan and that of America since 1980's. Regarding the process, similar situation is ongoing on the entertainment field in China. This paper intends to study potential of Chinese entertainment industry compared to the differences on programs between Korea and China by scoping out success of Korean entertainment program in China and the impact on Chinese entertainment market.

Zooplankton Community in the Front Zone of the East Sea of Korea (the Sea of Japan) : 1. Species List, Distribution of Dominant Taxa, and Species Association (동해 전선역 동물플랑크톤 군집 : 1. 종 목록, 우점종 분포, 종간 유연관계)

  • PARK Chul;CHOI Joong Ki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.225-238
    • /
    • 1997
  • Zooplankton distribution in the front zone was investigated in the East Sea of Korea (Sea of Japan). More than 100 taxa appeared in the study area, which was far diverse appearance being compared with those in West (Yellow Sea) and South Sea of Korea. In Nov. 1994, Paracalanus parvus, Oikopleura spp., and Noctiluca scintillans, which preferred warmer environment, predominated at the collection sites in the front zone, especially at warmer surface layer. But in Nov. 1995, when the surface water temperatures were about $2^{\circ}C$ lower than those of the previous year, cold water species of copepod Metridia lucens, immature forms of Calanus and Sagitta, and crustacean eggs dominated in the collection sites in front zone, which were geographically not Identical with those of the previous year. Vertical distributional patterns were not coincide among the taxa. This suggests that zooplankton has different specific habitat characteristics with temperatures. In general, those taxa with preference of warmer environments showed high probability of co-occurrance with low abundances while those that preferring colder environments showed low probability of co-occurrance with high abundances. It seems that warm water contributes to the high diversity of zooplankton in the front zone while cold water does to the high biomass.

  • PDF

Characteristics and long term variation trend of water mass in the coastal part of East Sea, Korea (동해연안 수괴의 특성과 장기변동 추이)

  • Yoon, Yi-Yong;Jung, So-Jung;Yoon, Sang-Chul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.59-65
    • /
    • 2007
  • Rapid variation of coastal ecosystem in the East Sea of Korea, such as fishery resource variation and subtropical chang of bentic flora, accordong to the global warming are actually noticed. In this study we try to identify the characterics of water mass existing in this coastal area and to consider the variation of their physical and chemical properties using data of temperature, salinity and dissolved oxygen obtained by National Fisheries Research & Development Institute from 1960 to 2005. The temperature of all water mass rise during last 45 years; the rise of North Korea Cold Water temperature (about $2.33^{\circ}C$) is 1.5 times higher than that of Tsushima warm water (about $1.6^{\circ}C$), and the temperature rise of Tsushima Surface Water, directly affected by climate chang is $2.57^{\circ}C$, higher than the atmospheric temperature rise during same period, indicating that subtropical change makes progress more rapidly in the coastal marine ecosystem than in the land ecosystem. Otherwise, the salinity in the surface water decrease $0.29\%_{\circ}$ during last 45 years due to the rising trend of rainfall with atmospheric temperature. The dissolved oxygen concentration in the all water mass make a decreasing trend. Specially for the North Korea Cold Water, the dissolved oxygen concentration diminish 0.021 mg/l per year and the decrease in the East Sea Proper Water indicate a change of inner water circulation system.

  • PDF

Current Limiting and Recovery Characteristics of Two Magnetically Coupled Type SFCL with Two Coils Connected in Parallel Using Dual Iron Cores (이중철심을 이용한 병렬연결된 자기결합형 초전도한류기의 전류제한 및 회복특성)

  • Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.717-722
    • /
    • 2016
  • In this paper, in order to support the peak current limiting function depending on the intensity of the fault current at the early stage of failure, a two magnetically coupled type superconducting fault current limiter (SFCL) is proposed, which includes high-Tc superconducting (HTSC) element 1, where the existing primary and secondary coils are connected to one iron core in parallel, and HTSC element 2, which is connected to the tertiary winding using an additional iron core. The results of the experiments in this study confirmed that the two magnetic coupling type SFCL having coil 1 and coil 2 connected in parallel using dual iron cores is capable of having only HTSC element 1 support the burden of the peak current when a failure occurs. The reason for this is that although HTSC element 1 was quenched and malfunctioned because the instantaneous factor of the initial fault current was large, the current flowing to coil 3 did not exceed the critical current, which would otherwise cause HTSC element 2 to be quenched and not function. In order to limit the peak current upon fault through the sequential HTSC elements, the design should allow it to have the same value as the low value of coil 1 while having coil 3 possess a higher self-inductance value than coil 2. In addition, a short-circuit simulation experiment was conducted to examine and validate the current limiting and recovery characteristics of the SFCL when the winding ratio between coil 1 and coil 2 was 0.25. Through the analysis of the short-circuit tests, the current limiting and recovery characteristics in the case of the additive polarity winding was confirmed to be superior to that of the subtractive polarity winding.

A Study on Sea Water and Ocean Current in the Sea Adjacent to Korea Peninsula -III. Chemical Characteristics of Water Masses in the Polar Front Area of the Central Korean East Sea- (한반도 근해의 해류와 해수특성 -III. 한국 동해 중부 극전선역에 출현하는 수괴의 화학적 특성-)

  • YANG Han-Soeb;KIM Seong-Soo;KANG Chang-Geun;CHO Kyu-Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.3
    • /
    • pp.185-192
    • /
    • 1991
  • The vertical distribution and chemical characteristics of water masses were measured along two south-north transects in the polar front region of the central Korean East Sea. In February, a thermocline was present at depth between 50m and loom at the southern sites of a landward A-transect, and its depth was gradually deepened northward. At an outside B-transect, a thermocline was observed at significantly deep depth of 300m to 400m at two northern stations(Stn. 10 and 11), though the depth of the southward stations was nearly identical to that at the northward stations on a A-transect. In September, there were vertically more various water masses, i.e. the Tsushima Warm surface water(TWSW) or more than $20^{\circ}C$, the Tsushima Middle water(TMW) with a range of $12{\~}17^{\circ}C$, the North Korea Cold Water(NKCW) with $1{\~}7^{\circ}C$ temperature, the Japan Sea Proper Water(JSPW) of less than $1^{\circ}C$, and the mixed water. The North Korea Cold Water could be distinguishable from the other waters, especially from the mixed water of the Tsushima Middle Water and the Japan Sea Proper Water by the pattern of $T-O_2$ diagram. For instance, the North Korea Cold Water had higher oxygen by $1{\~}2ml/l$ than those in the mixed water, although both the two water masses ranged $1{\~}7^{\circ}C$ in water temperature. AOU value was the highest in the JSPW and the lowest in the TWSW. Also, AOU indicated a nearly linear and negative correlation with water temperature. However, AOU data for two masses, the NKCW and the TMW, in September departed remarkably from a regression line. Moreover, the ratio of $$\Delta P/\Delta AOU)$ in September was about $0.45{\mu}g-at/ml$ and higher than the value observed in the open sea. This high value could be elucidated by two factors; intrusion of the NKCW with high oxygen and molecular diffusion of dissolved oxygen from the surface into the lower layer. AOU would be a useful tracer for water masses in the polar front area of the Korean East Sea.

  • PDF

Characteristics of Acoustic Environment in three regions along the Korean East Coast (한반도 연안 3개 해역에서의 수중음향환경 특성)

  • Park S.W.;Yun J. Y.;Kim K.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.417-420
    • /
    • 2004
  • 동해는 크게 북한한류계수의 지배적인 영향을 받는 북부해역, 동한난류계수의 지배적인 영향을 받는 남부해역과 이들이 만나서 극전선이 형성되는 중부해역 등 세 해역으로 구분할 수 있고 이러한 환경에서의 해군 함정의 대잠탐지환경은 같은 동해라 하더라도 크게 다를 것으로 예상된다. 본 연구에서는 저주파 거리종속 모델인 RAM 을 이용하여 평균해황 하에서 각 해역에서의 전달손실 값을 비교하였다. 음원을 수심 100m, 수신기 수심을 10m와 100m로 설정하여 실험을 하였으며 아울러 평균해황이 아닌 일정시기에 관측한 순간해황 자료를 통한 모델결과도 같이 분석하였다. 실험결과, 연안에 위치한 음원으로부터 음파가 외해로 전달됨에 따라 냉난수대간의 수온전선 영향을 받게되며 수온전선을 통과하면서 남부해역에서의 음파는 중부 및 북부해역 보다 난류의 영향을 더 많이 받게된다. 따라서 북부보다는 중부해역이, 중부보다는 남부해역에서의 전달손실값이 더 커지게 된다. 특히 이러한 경향은 북한한류계수가 발달하여 난류와 수온전선이 형성되는 8월에 더 큰 것으로 나타났다.

  • PDF

Quench Characteristics of Flux-Lock Type Superconducting Fault Current Limiter According to The Number of YBCO (YBCO의 직렬연결에 따른 자속구속형 초전도 한류기의 퀜치특성)

  • Lee Sang-Il;Park Hyoung-Min;Choi Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.329-333
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the number of the serial connection between the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity windings depending on the winding directions between the primary and secondary coils. In this paper, the analyses of voltage, current, and resistance of superconducting elements in serial connection were performed to increase the power capacity of flux-lock type SFCL. The power burden was reduced through the simultaneous quenching between the superconducting elements. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films (15 kVA급 박막형 초전도 전류제한기의 한류특성)

  • 최효상;현옥배;김혜림;황시돌
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

Test of a Current Limiting Module for Verifying of the SFCL Design (초전도 한류기 설계 검증을 위한 초전도 한류 모듈 단락 특성 시험)

  • Yang, S.E.;Kim, W.S.;Lee, J.Y.;Kim, H.;Yu, S.D.;Hyun, O.B.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.13-17
    • /
    • 2012
  • KEPCO Research Institute has been researching a Superconducting Fault Current Limiter (SFCL) which is considered one of solutions of fault current problems with Korea Institute of Machinery & Materials (KIMM) and Hanyang University since 2011. In this paper, we fabricated a current limiting module and conducted electrical short circuit tests for checking the validity of the transmission level SFCL design. Based on the short circuit characteristics of the second generation High Temperature Superconductor (HTS), we analyzed the short circuit characteristics of 3 parallel connected superconducting wires. The structure of the HTS wire is as follows: the stainless steel stabilizer of $100{\mu}m$ is laminated on the superconductor layer and under the substrate, both of which are electrically jointed with solder. We fabricated the current limiting module which has 40 series and 6 parallel connections and studied the short circuit characteristics of the module under various voltage levels.

Quench Characteristics of Resistive SFCL Elements in series (직렬 연결된 초전도 한류기의 퀜치 및 한류 특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.663-665
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter saphire substrates Two SFCLs with nearly identical properties were connected in series to investigate the simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference. however, resulted in significantly unbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. The appropriate values of the shunt resistances were $80{\Omega}$ at $75 V_{rms}$. $100{\Omega}$ at $100 V_{rms}$ and $110{\Omega}$ at $120 V_{rms}$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation. but with increase in film temperature to higher than 200 K.

  • PDF