• 제목/요약/키워드: 한류기

검색결과 379건 처리시간 0.021초

모의배전계통에 두 트리거 전류레벨을 이용한 초전도한류기의 전류제한 특성 분석 (Current Limiting Characteristics of a SFCL with Two Triggered Current Limiting Levels in a Simulated Power Distribution System)

  • 고석철;한태희
    • 한국전기전자재료학회논문지
    • /
    • 제26권2호
    • /
    • pp.134-139
    • /
    • 2013
  • When the accident occurred in power distribution system, it needs to control efficiently the fault current according to the fault angle and location. The flux-lock type superconducting fault current limiters (SFCL) can quickly limit when the short circuit accidents occurred and be made the resistance after the fault current. The flux-lock type SFCL has a single triggering element, detects and limits the fault current at the same time regardless of the size of the fault current. However, it has a disadvantage that broken the superconductor element. If the flux-lock type SFCL has separated structure of the triggering element and the limiting element, when large fault current occurs, it can reduce the burden of power and control fault current to adjust impedance. In this paper, this system is composed by triggering element and limiting element to analyze operation of limiting current. When the fault current occurs, we analyzed the limiting and operating current characteristics of the two triggering current level, and the compensation characteristics of bus-voltage sag according to the fault angle and location.

이중퀜치를 이용한 자속구속형 초전도한류기의 과도전류제한 특성 (Transient Current Limiting Characteristics of Flux-Lock Type SFCL Using Double Quench)

  • 최상재;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.96-100
    • /
    • 2017
  • In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two $high-T_{c}$ superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both $0^{\circ}$ and $90^{\circ}$ fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.

6.6kV-200A급 DC 리액터형 고온초전도한류기의 최적설계 (Optimal Design of 6.6kV-200A DC Reactor Type High-Tc Superconducting: Fault Current Limter)

  • 서호준;이승제;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.99-104
    • /
    • 2002
  • This study deals with the optimal design of a DC reactor type high-Tc superconducting fault current limiter(SFCL). The condition in which the cost function is minimized under given constraints is one of the things to be first considered in developing SFCLS. This condition is a group of the values corresponding to the variables the cost function depends on. In this paper, the length of tape was taken as a dependent variable, the inductance of DC reactor and the turns ratio of magnetic core reactors as independent variables. For the SFCL available at the level of 6.6kV-200A, we examined 4 cases; at the fault times of 80msec, 50msec, 30msec and 10msec. Since thyristors would be utilized instead of diodes, we chose the result at 10msec as the basic data. Considering safety factor 30%, our optimal design was decided to be the inductance 570mH, the critical current over 620A, the turns ratio 0.89 and the fault time within 20msec.

3차권선이 추가된 직렬연결형 초전도한류기의 전류제한 및 회복 특성 향상 (Improvement of Current Limiting and Recovery Characteristics in Series Connection Type SFCL with Added Third Winding)

  • 고석철;한태희;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.62-68
    • /
    • 2014
  • The series connection type superconducting fault current limiter (SFCL) with added third winding, which was magnetically coupled in one iron core, was proposed. The proposed SFCL was expected to be more improved by just adding third winding into the conventional series connection type SFCL with two coils. To analyze the contribution of the third winding for the current limiting and the recovery characteristics of the SFCL, the short-circuit tests for the series connection type SFCL with the added third winding were performed together with the analysis on its electrical equivalent circuit. From the comparative analysis on the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising this SFCL, the improved current limiting and recovery characteristics of the series connection type SFCL using the third winding could be confirmed.

개루프 철심을 이용한 자속구속형 초전도한류기의 퀜치특성 (Quench Characteristics of Flux-lock type Superconducting Fault Current Limiter using Open-loop Iron Core)

  • 남긍현;최효상;박형민;조용선;이나영;임성훈;박충렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.159-160
    • /
    • 2005
  • The superconducting fault current limiter(SFCLs) provides the effect such as enhancement in the power system reliability due to limiting fault current in a few miliseconds. The Flux-lock type SFCL using the YBCO film among various type SFCLs consists of the primary and the secondary copper coils that are wound in parallel each other through the iron core. The operation can be controlled by adjusting the inductances and the winging directions of each the coil. We compared the current limiting performance on the additive and the subtractive polarity winding directions in case of an open-loop iron core. To analyze quench characteristics, we experimented various phase angle.

  • PDF

트리거형 초전도한류기의 접점구성에 따른 전류제한 및 회복특성 분석 (Analysis on Current Limiting and Recovery Characteristics of a Trigger Type SFCL as the Composition of the Contact)

  • 최종수;김명후;유일경;김진석;임성훈;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.159-164
    • /
    • 2010
  • We experiment to analyze on current limiting and recovery characteristics of trigger type SFCL as the composition of the contact. Generally, some superconductor of SFCL is relatively largely loaded due to limit the fault current by oneself and recovery time is affected until the fault cleared. However, in the fault, the proposal trigger type SFCL transfer the fault current to current limiting reactor(CLR) using power switch so it could reduce the recovery time and load of the superconductor. However, because of applying the additional power switches, that could generate some power loss. Therefore, to solve this problem, we proposed the composition method of the double contact for a trigger type SFCL and analyzed on current limiting and recovery characteristics for ones.

한류를 위한 In-Apps 방식의 e-pub player 개발 (E-pub player for K-POP)

  • 김시우;강지애;김유정;반소정;임유남;정지영;강혜린;윤인희;천선화
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2012년도 제46차 하계학술발표논문집 20권2호
    • /
    • pp.287-288
    • /
    • 2012
  • 본 논문에서는 소비자 스스로 검색하는 콘텐츠를 분석하여 그 중 인지도가 높은 콘텐츠를 제휴하여 서비스 를 제공한다. 인지도 높은 동영상 콘텐츠에 전자책을 제작하여 새로운 콘텐츠로 재제작 유료 서비스 추진 하고 인지도 높은 전자책 콘텐츠를 동영상과 함께 새로운 콘텐츠로 제작하여 유료 서비스 추진한다. 그리고 콘텐츠 보유 개인, 기업 및 단체와 제휴를 통한 서비스 추진할 수 있고 나아가 번역기를 통한 다국어서비스로 글로벌 콘텐츠 서비스 추진한다.

  • PDF

저항형 초전도한류기의 신뢰도 모델을 적용한 배전계통 신뢰도 평가에 관한 연구 (A Study on the Evaluation of Distribution Reliability Considering Reliability Model for a Resistive-Type of Superconducting Fault Current Limiter)

  • 김성열;김욱원;김진오
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.465-470
    • /
    • 2011
  • Recently fault currents are increasing in a network. It is caused by increase in electric demand and high penetration of distributed generation with renewable energy sources. Moreover, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. Accordingly, the fault current will exceed capacity of circuit breakers soon and all the various rational solutions to solve this problem are taken into account. Under these circumstances, superconducting fault current limiter(SFCL) is a new alternative in the viewpoint of technical and economic aspects. This study presents operation processes for a resistive-type of SFCL, and it proposes reliability model for the SFCL. When a SFCL is installed into a network, the contribution of decreased fault currents to failure for distribution equipments can be quantified. As a result, it is expected that a SFCL makes the reliability of adjacent equipments on existing network improve and these changes are analyzed. We propose a methodology to evaluate the reliability in the distribution network where a SFCL is installed considering a reliability model for resistive-type of SFCL and reliability changes for adjacent equipments which are proposed in this paper.

Thyristor를 이용한 교류과전류 차단에 관한 연구 (A study on AC over-current breaker using thyristor)

  • 박민호;심재명
    • 전기의세계
    • /
    • 제28권7호
    • /
    • pp.49-55
    • /
    • 1979
  • 본논문은 Thyristor를 이용하여 교류회로의 고장전류를 차단하는 기구에 대한 것이다. 즉 Thyristor 한류차단회로를 설정하고 게이트제어회로 과전류검출기를 설계하고 동작과정을 확인하였다. 결과에 있어서 (1) 고속차단이 가능하다(60Hz 교류에서 4ms이내) (2) 이 방식에 의하면 차단용량을 감소시킬 수 있다. (3) 적은 신호로 지체없이 동작한다. (4) 기계적부분이 없으므로 반영구시 수명을 가진다.

  • PDF

분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구 (Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation)

  • 임승택;임성훈
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.