• Title/Summary/Keyword: 한국전기안전공사

Search Result 133, Processing Time 0.023 seconds

A Study on the Influence of Electronic Construction Site Safety Managers' Job Resources, Job Demands, and Organizational Commitment (전기공사 현장 안전관리자의 직무자원, 직무요구 및 조직몰입의 영향 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Son, Minjie;Hong, Ah-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.39-48
    • /
    • 2021
  • This study was conducted to suggest a direction in which safety managers can concentrate on industrial accident prevention and safety management for the organization. The job resources of safety managers were divided into organizational and individual levels, and the magnitude of the impact on organizational commitment was compared. Furthermore, job demands were classified into environmental risk factors and personal psychological factors to confirm their effect on organizational commitment. The moderating effect of job resources and sub-factors of the variable in the relationship between job demands and organizational commitment was verified. In this study, a questionnaire survey was conducted on 193 safety managers in the domestic electric construction business, data were collected, and a questionnaire of 180 people was used for the final analysis. Based on the results, organization-level resources among the sub-factors of job resources and individual psychological factors among the sub-factors of job demand had a more significant influence on organizational commitment. In the relationship between job resources and organizational commitment, the moderating effect of job demand was verified, confirming that job demand had a negative moderating effect. Individual psychological factors had a modulating effect, whereas environmental factors did not. The significance, implications, and limitations of this study are discussed based on the research results.

A Study for Performance Estimation Standard and Standardization of u-IT Convergence Equipment (u-IT Convergence 기기의 성능평가기준과 표준화 연구)

  • Chun, Woo-Sung;Park, Dea-Woo;Lee, Sang-Ick;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.457-460
    • /
    • 2009
  • u-IT Convergence appliances study and are developed in communication by development of u-IT technology, broadcasting, portal, contents, equipment and all fields of business such as solution. This treatise presents valuation basis of, economic performance, administration sex etc. by temperature, pressure, own, storehouse, gas, justice for humidity sensors and valuation basis that define u-IT Convergence, and sense information u-IT Convergence devices and terminal. Also, studied standardization standard of u-IT Convergence network appliance that follow in valuation basis for u-IT Convergence devices. Is going to contribute establish value as estimation product that equip stability and authoritativeness through correct certification assessment for technological development and appliances on Ubiquitous information-oriented society through this research and accomplish standardization.

  • PDF

Real-time Water Supply Facilities Monitoring System based on the USN (USN 기반의 실시간 수도설비 모니터링 시스템)

  • Kim, Yong-Tae;Yoo, Neung-Hwan;Park, Gil-Cheol;Kim, Seok-Soo;Kim, Tai-Hoon;Lee, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1207-1213
    • /
    • 2007
  • This paper has researched water supply facilities management using real-time water utility monitoring system based on USN(Ubiquitous Sensor Network) which is consisted of wireless sensors transferring waterworks facilities md treatment information about a valve-room and flowmeter-room of water supply installation. In the manholes, it was installed with flowmeter, pressure sensors, vibration sensors, Co-sensors, and hydro-thermograph sensors. These measurement values which are received by PDA are used for facilities operation on the spot safely and conveniently. It has also provided safe installation management via CDMA(Code Division Multiple Access) network which transfers data to remote servers to monitoring at a distance place. With safety management system of water supply facilities on USN technology convenience and safety is increased in real situation, and it is expected that we can supply clean water to people as much safer and more effective water supply installation management.

Development for establishing Big Data-based alley commercial area (빅데이터 기반 골목상권 영역설정 방법론 개발)

  • Hwang, Dong-Hyun;Ko, Kyeong-Seok;Park, Sang-June;Kim, Wan-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.6
    • /
    • pp.784-792
    • /
    • 2018
  • In this study, we designed the area except the development market and the traditional market, where large scale shops were concentrated by realizing the real estate center of the alley commercial area. In addition, we have developed an area setting method for the alley area where reliability and rationality can be ensured by utilizing the actual data such as the business statistics, the survey data of the business, and the store business DB, which are managed by the local government or the state. The alley commercial areas were classified into five groups according to density. It is thought that users can distinguish the commercial areas from dense commercial areas to the commercial areas in order to utilize various commercial areas.

Helmet and Mask Classification for Personnel Safety Using a Deep Learning (딥러닝 기반 직원 안전용 헬멧과 마스크 분류)

  • Shokhrukh, Bibalaev;Kim, Kang-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.473-482
    • /
    • 2022
  • Wearing a mask is also necessary to limit the risk of infection in today's era of COVID-19 and wearing a helmet is inevitable for the safety of personnel who works in a dangerous working environment such as construction sites. This paper proposes an effective deep learning model, HelmetMask-Net, to classify both Helmet and Mask. The proposed HelmetMask-Net is based on CNN which consists of data processing, convolution layers, max pooling layers and fully connected layers with four output classifications, and 4 classes for Helmet, Mask, Helmet & Mask, and no Helmet & no Mask are classified. The proposed HelmatMask-Net has been chosen with 2 convolutional layers and AdaGrad optimizer by various simulations for accuracy, optimizer and the number of hyperparameters. Simulation results show the accuracy of 99% and the best performance compared to other models. The results of this paper would enhance the safety of personnel in this era of COVID-19.

Risk Assessment of Cut Slope by Gravity Field Interpretation and Modelling (비탈면 위험도 평가를 위한 중력장 해석 및 모델링)

  • Choi, Sungchan;Kim, Sung-Wook;Choi, Eun-Kyoung;Lee, Yeong-Jae;Jang, Hyun-Ick
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.533-540
    • /
    • 2021
  • Gravity field analysis and density modeling were performed to evaluate the internal state of the rock mass, which is the cause of cut slope collapse. The shape of the weathered zone and the depth of basement could be confirmed from the complete Bouguer anomaly and density model. The basement depth at the center of the cut slope calculated using the Euler deconvolution inverse method is 30 m, which is about 10 m deeper than the surrounding area. In addition, the depth of basement and the thickness of the weathered zone are similar to the boundary between low resistivity and high resistivity in dipole-dipole survey. From the study results, gravity field analysis and density modeling recognizes the internal state of the rock slope and can be used for slope safety analysis, and is particularly suitable as a method to determine the shape of weathered zones in interpreting the safety of cut slopes

Agricultural Geophysics in South Korea: Case Histories and Future Advancements (우리나라 농업 물리탐사: 적용 사례와 향후 과제)

  • Song, Sung-Ho;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.4
    • /
    • pp.244-254
    • /
    • 2018
  • The first geophysical technique applied to the agricultural sector in Korea was electrical resistivity sounding and conducted in purpose of groundwater exploitation in the 1970s. According to the diversity of agricultural activities since the 1990s, various geophysical methods including electrical resistivity, electromagnetic induction, and self-potential method were applied to several agricultural fields such as soil characterization with saline concentration in vast reclaimed area, delineation of seawater intrusion regions in costal aquifer, safety inspection of embankment dikes with leakage problem, detection of ground subsidence from overpumping and tracing of groundwater aquifer contamination by leachate from livestock mortality burial or waste burial site. This paper introduces representative geophysical techniques that have been utilized in various agricultural fields and suggests several ways to develop the geophysical methods required for the precision agriculture field in the near future based on the past achievements.

Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong (의성 탑리리 오층석탑 기단부 전기비저항 탐사)

  • Oh, Hyundok;Kwon, Moonhee
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.253-260
    • /
    • 2020
  • The five-story stone pagoda in Tamni-ri located in Uiseong County in Gyeongsangbuk-do had an unstable upper structure, and the structural deformation of the foundation stone and the stylobate was severe. In order to repair the base of the pagoda, it must be confirmed if there are support stones inside the base. Resistivity survey was performed to study the inner base stone structure during the repair work. The stylobate was exposed soil and broken stones after removing the walls and the cover of the stylobate. Modified pole-dipole array II was used for the resistivity survey, and compared with the typical pole-dipole array method. And in this study, a physical scale-down model experiment was performed to compare and analyze distortions caused by severe topographical undulations such as right-angled lines. The results show that the stylobate of Five-story Stone Pagoda in Tamni-ri Uiseong has base stones inside the reinforced filling soil and are located beneath the pillar of the body and supporting the pagoda.

Design of Sedimentary Rock Slopes in River Diversion Works (가배수로 터널공사의 퇴적암 사면 안정화 설계)

  • Jee, Wang-Ruel
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.17-32
    • /
    • 1998
  • The Bakun hydroelectric project includes the construction of a hydroelectric power plant with an installed capacity of 2,520MW and a power transmission system connecting to the existing transmission networks in Sarawak and Western Malaysia, The power station will consist of a 210m height concrete faced rockfill dam. During the construction of the dam and the power facilities the Balui river has to be diverted by three diversion tunnels with a length of some 1,400m each. The inner diameter of the tunnels is 12m and the tunnel width is 16m at the portal area. This paper describes the stability analysis and design methods for the open cut rock slopes in the inlet and outlet area of the diversion tunnels. The geotechnical parameters employed in stability calculations were given as a function of four. defined Rock Mass Types (RMT) which were based on RMR system from Bieniawski. The stability calculations procedure of the rock slopes are divided into two stages. In the first stage, it is calculated for the stability of each 'global' slope without any rock support and shotcrete system. In the second stage, it is calculated for each 'local'slope stability with berms and supported with rock bolts and shotcrete. The monitoring instrumentation was performed continuously and some of the design modification was carried out in order to increase the safety of failed area based on the unforeseen geological risks during the open cut excavation.

  • PDF

An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines (2회선 가공송전선의 단시간정격에 관한 평가방법)

  • Kim, Sung-Duck;Sohn, Hong-Kwan;Jang, Tae-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.20-28
    • /
    • 2007
  • This paper describes an analytical method to determine the short-term ratings to reliably operate the overhead transmission lines with double-circuit lines when faulting one circuit of the two. As linearizing the thermal equilibrium equation that represents the temperature characteristic of conductors, we show that the linear equation can be easily represented the over-current and it's temperature property during overloading the one line. Generally, it is well hewn that the short-term line ratings should be determined by considering both conductor life and dip. However, most power companies have their own different guides for the short-term ratings. Using the suggested method in this paper, it can be re-accessed the short-term ratings given in Kepco's overhead transmission lines constructed during the past three different periods. As a result, it is verified that the short-term ratings could be increased mil efficiently. Furthermore, it would be directly applied the given method to determine the short-term dynamic line ratings when occurring faults in one of the double-circuit lines, without doing my other actions for the current lines.