• Title/Summary/Keyword: 한국안광학회지

Search Result 1,159, Processing Time 0.025 seconds

A Study of The Integrating Sphere for Measurement of Reflectanoe and Transmittance (투과율 및 반사율 측정을 위한 적분구에 관한 연구)

  • Kim, Sang Yeoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.91-95
    • /
    • 1997
  • A General equation is developed for the efficiency of an integrating sphere with a nonuniform coating. The only assumptions are that the interior is a perfect sphere and that all areas reflect perfectly diffusely. The general equation are examined for the basic applications of integrating spheres as mixing mechanisms in hemispherical reflectance measurements and in absolute reflectance techniques.

  • PDF

The Variable Process of Visual Acuity for Artificial Myopia (인위적인 근시에서 시력의 회복과정)

  • Choi, Woon Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 1997
  • Numerically compares a calculation about a variable process of visual acuity for a artificial myopia with previously the tested result. The calculation is used to the value of Gullstrand's theoretical eyes and a method of geometrical optics. The theoretical eye simplified a entrance pupil and retina. Optical lens and eye changed a equivalent lens. Refractive power of a equivalent lens is converted to focal length within theoretical eyes, and this was calculated about relation of a blur circle on the retina and visual acuity.

  • PDF

A Study on the Optical Properties of Eye-glasses (안경렌즈의 광학적 성능에 관한 연구)

  • Lim, Hyeon Seen;Ji, Taek Sang;Kim, Bong Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.31-43
    • /
    • 1997
  • In this paper, the rate of transmittance regarding the home -and foreign-made lens that have been treated with multi coating and no coating has been studied in the range of the visible ray. The lens that were treated with No Coating turned out to be about 93% of the rate of transmittance, but those treated with Coating turned out to be over 98%. Especially, the rate of transmittance of product made by a company in a foreign country turned out to be homogeneous in the whole range.

  • PDF

Case Study of Vision Therapy (양안시이상 교정의 일상사례)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.87-93
    • /
    • 2007
  • Eye examination was performed for diagnosis accommodative and binocular dysfunction. The prevalence rates were similar to other studies, therefore patients required not just the correction of the refractive error but a specific treatment for each diagnosed problems. Two symptomatic(diplopia, asthenopia, and intermittent blur) patients diagnosed as a convergence insufficiency was given full correction with visual training for 4weeks. They had a one or mixed binocular problems included accommodative insufficiency. Following 4 weeks later, visual training was effective to Improve convergence and suggest that continuous observation is necessary.

  • PDF

Optical properties of ink color filters (잉크 색상 필터의 광학적 특성)

  • Lee, Chan-Ku;Lee, Su-Dae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.23-28
    • /
    • 2003
  • We report a switchable RGB color filters for Lab on a chip. Ink color filter devices are fabricated by PDMS patterning process. The optical transmission in the ultra-violet and visible wavelengths of color filters have been investigated. The ink color filters are characterised by the slope and shape of the spectrum. The transmission of red/yellow filter consists of curves with a sharp cut-off spectrum at 600 and 500 nm. The blue output of the ink filter has 80% peak transmission and weak red-leak, while the green ink filter has 48% peak transmission and red-leak.

  • PDF

A study on the characteristics of Ti frame using filler metal at brazed joints (납재를 이용한 티타늄(Ti) 안경테의 땜질 접합부의 특성에 관한 연구)

  • Kim, Dae-Nyoun;Kim, Ki-Hong;Kim, Hye-Dong;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.47-52
    • /
    • 2003
  • The metallurgical and mechanical experiments of Titanium frame were conducted to investigate the optimum brazing and the improved brazed joints by filler metals has been developed by using other filler metals at brazing process. The filler metal is used in form of a metallic glass. The optimum brazing conditions were obtained from microstructural observation of brazed joints chemical analysis by means of X-ray micro-analysis and heating method.

  • PDF

The variation of visual acuity for a artificial myopia concerned with the fogging technique (운무법과 같은 인위적인 근시상태에서의 시력 변화)

  • Choi, Woon Sang;Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.43-47
    • /
    • 1996
  • For youths of both sexes which can read the letter chap of 1.0 acuity without lens, tests the fogging technique and examines the development of visual acuity. And compare the numerical function with the result of the variation of the blur circle on the retina when the power of the fogging lens varies. The variation of visual ac acuity for the fogging technique keeps constantly the balance for binocular.

  • PDF

Materials for Spectacle lens cutting with Glass phase (유리상 첨가한 안경렌즈 절삭용 재료)

  • Lee, Young-II
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.145-148
    • /
    • 2001
  • SiC composites were developed by incorporating glass phase into SiC, in the light of improving mechanical properties of material for spectacle lens cutting. Specimens for spectacle lens cutting with glass phase as sintering additives have been fabricated by hot-pressing at $1810^{\circ}C$ for 2 hr under a pressure of 25 MPa. The fracture toughness and hardness of hot-pressed specimens were characterized and compared with previous works. Typical hardness and fracture toughness of materials for spectacle lens cutting were 12 GPa and $5.1MPa{\cdot}m^{1/2}$ respectively.

  • PDF

The Analysis of Color Vision Defects Mechanism for the Electric Circuits (전기적 회로에 의한 색각이상 mechanism 해석)

  • Park, Sang-An;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.81-85
    • /
    • 2001
  • The color vision was composed of the wavelength absorption of three R. G. B cone photo-receptors and the r-g, y-b channel of an opponent process. The color vision defects mechanism for the electric circuit made up a photo cell, relay switch and transformer. This mechanism very well applied to the color vision defects mechanism owing to be y-b chromatic valence function in case of a cone R or G defects and to be r-g chromatic valence function in case of a cone B defects.

  • PDF

A Study on DLC Hard Coating in Ocular Lens(CR-39) (안경렌즈(CR-39)에의 DLC Hard 코팅에 관한 연구)

  • Lee, Won Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.87-91
    • /
    • 2001
  • The a-C:H films have been grown on the glass substrate by PECVD method, where plasma was generated with a 60 Hz line power source. The carbonization is checked from peak intensities of D($sp^3$) and G($sp^2$) peaks in Raman spectra and is analyzed using the Gaussian convolution method of spectrum. Both the bonding strength of C-H and the ratio of $sp^3$ to $sp^2$ in bonding are found to be slightly dependent of partial pressure of $C_2H_2$.

  • PDF