• Title/Summary/Keyword: 한국안광학회지

Search Result 1,159, Processing Time 0.021 seconds

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Correlation between Critical Micelle Concentration/Surface of Contact Lens Care Solutions Tension and Their Cleaning Efficacy (콘택트렌즈 관리용액의 미셀임계농도 및 표면장력과 세척력 간의 상관관계)

  • Byun, Hyun Young;Sung, Hyung Kyung;Moon, Joon Sik;Lee, A Young;Kwon, Se Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The present study was aimed to figure out the correlation amongst the evaluation methods for critical micelle concentration, surface tension and protein cleaning efficacy to evaluate cleaning efficacy of contact lens care products. Methods: The critical micelle concentration of surfactants and the actual concentration of surfactants in contact lens care solutions were investigated by employing references published and related information. Surface tension of contact lens care solutions was measured by surface tension device at $25{\pm}1^{\circ}C$, and contact lenses made of lotrafilcon A, comfilcon A and balafilcon A were washed with contact lens care solutions after the incubation in artificial tears for 14 days and their cleaning efficacy was compared. Results: Among the 22 contact lens care products, 9 products provided the label of the concentration of surfactant, and 7 products showed higher concentration of surfactant than the critical micelle concentration reported in references. As a result of measuring surface tension, the surface tension of lens care products for soft contact lens was generally lower than other care products. When examined the removal effect of protein deposited on lens surface, it was known that the care products having lower surface tension showed higher protein removal efficiency. Conclusions: The surface tension is low when surfactant concentration in contact lens care solutions is high, and the removal effect of protein deposited is accordingly increased with the decrease of surface tension. Thus, these indicate the correlation amongst the evaluation methods for cleaning efficacy.

Comparison to Contrast Sensitivity of Male and Female Adults in Their 20s (20대 성인 남녀의 대비감도 비교)

  • Choi, Soon-Lyoung;Han, Kwang-Lae;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.87-92
    • /
    • 2014
  • Purpose: Comparison with contrast sensitivity between binocular and monocular of 20s adult was measured by spatial frequency 3.0, 6.0, 12.0 and 18.0 cpd and compares difference between monocular and binocular and difference between male and female. Methods: Topcon CV-3000 Phoroptor was used for full correction of 99 ophthalmic optics students and contrast sensitivity were measured by using Vector Vision CSV-1000E at 2.5 m in photopic condition (100 $cd/m^2$). Results: Photopic condition at 2.5 m, average contrast sensitivity of entire subject was 52.54, 80.40, 36.79 and 13.56 with right eye and 52.33, 81.29, 41.73 and 14.22 with left eye in 3, 6, 12 and 18 cpd. For both eye 65.46, 113.69, 52.04 and 19.44 were measured. The contrast sensitivity of male was 58.22, 83.52, 37.89 and 13.82 with right eye and 56.03, 46.68 and 15.67 with left eye in spatial frequency of 3, 6, 12 and 18 cpd. Both eyes were measured to 70.89, 120.96, 56.56 and 19.89. The contrast sensitivity of female was 46.50, 77.09, 35.61 and 13.28 with left eye and 48.40, 70.43, 36.47 and 12.68 with left eye in spatial frequency of 3, 6, 12, 18 cpd. Both eyes were 59.68, 105.97, 47.23 and 18.95. Conclusions: Contrast sensitivity value of binocular shows higher than monocular to both male and female. Contrast sensitivity of difference between male and female were statistically remarkably higher to male in right eye 3 cpd, left eye 6 cpd, 12 cpd and both eye 3 cpd. In other frequency, there was no statistical significance but male shows higher.

Design and Fabrication for the Development of Auto Pattern Maker (자동취형기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Purpose: To design and fabricate the auto pattern maker for the development. Methods: we got the necessary data, needed in design, by using CAD. Based on the these data, we fabricated the trial product for the development of the auto pattern maker. Results: The auto pattern maker were composed with combinations of many elements; pattern making assembly, control panel, frame attachment and prober unit. The pattern making assembly was comprised of the cutter, the pattern holder, pattern remover and silence cover which could minimize the sound during the cutting process. The control panel was designed to be connected and operated with the main printed circuit board. The prober could get the eye shape data by scanning of 1.8 degrees around the groove of the frame through the encoding data according to the address. After starting, scanning was carried out in two passes, i.e. one right-handed and one left-handed. Communication connector could send the eye shape data from auto pattern maker to outer system with the RS232C transmission system. By using the one-way analysis of variance, we got the error rate of cut pattern size for ${\Phi}22mm$, ${\Phi}55mm$ and ${\Phi}62mm$. Because F-value was 0.510 and p-value was 0.601, no statistically significant differences were found. Also, the mean cutting error of the auto pattern maker was 0.0274 mm. Conclusions: we could succeed in making the trial product by applying it to the development of the auto pattern maker. The role of this auto pattern maker is to find a exact required size of lens to fit the frame by measuring the frame. The acquired data are transferred to outer system for grinding and finishing with patternless process. Also, the trial product can produce pattern to fit the frame. Therefore, it was confidently expected that the optometrists could handily produce pattern to fit the frame with this trial product and dispense the ophthalmic lens because of its efficiency and convenience compared to the past.

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

The Inhibitory UV-B Blocking Rate of Eyeglasses Lens on the Enzymes Denaturation in Cornea (각막 내 효소의 변성을 억제하는 안경 렌즈의 UV-B 차단율)

  • Kim, So Ra;Lee, Jee Hee;Choi, Jung-Im;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.253-260
    • /
    • 2013
  • Purpose: To investigate the UV-B blocking rate of eyeglasses lens which can prevent enzymes denaturation in cornea. Methods: The denaturation degree of RNase A and catalase, superoxide dismutase (SOD) was determined by using Acrylamide gel electrophoresis after UV-B irradiation of 312 nm for 1, 3, 6, 24 and 96 hours. Also, the inhibitory effect of eyeglasses lens having UV-B blocking rate of 50%, 80%, 95% and 99% on the enzymes denatration was measured. Results: The denaturation of RNase A was induced by 1 hour-irradiation of UV-B. To inhibit RNase A denaturation after UV-B irradiation between 1 hour and 6 hours, UV-B blocking lens of 95% were effective. UV-B blocking lens of 99% suppressed the inhibition of RNase A denaturation after the UV-B exposure between 24 hours and 96 hours. The denaturation of catalase was not induced by 1 hourirradiation of UV-B. To inhibit enzyme denaturation after UV-B irradiation between 1 hour and 6 hours, UV-B blocking lens of 50% were effective. UV-B blocking lens of 95% suppressed the inhibition of enzyme denaturation induced by UV-B irradiation between 24 hours and 96 hours. The SOD denaturation was not induced by UV-B irradiation shorter than 6 hours exposure. The UV-B blocking lens of 50% could inhibit SOD denaturation after the UV-B irradiation for 24 hours. When SOD was exposed to UV-B for 96 hrs, SOD denaturation was inhibited by eyeglasses lens with UV blocking rate higher than 95%. Conclusions: The results demonstrated that the proper UV-B blocking rates of eyeglasses lens to inhibit the enzymes denaturatioin was different according to the types of enzymes and its inhibitory effect was effective only when eyeglasses lens had higher than certain UV-B blocking rate.

Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens (콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성)

  • Sung, Yu-Jin;Ryu, Geun-Chang;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2013
  • Purpose: Adsorption properties of lysozyme and albumin according to physiochemical properties of commercial contact lens classified with the FDA categories and a contact lens fabricated in the laboratory were investigated. Methods: The contact lens were prepared using HEMA(2-hydroxyethyl methacrylate) and TRIM(3-(trimethoxysilyl) propyl methacrylate) in a cast mold. Artificial tears containing lysozyme and albumin were prepared. We measured the amounts of protein adsorbed on the each lenses with varying adsorbed time (48 hour) and the pH range (6, 6.8, 7.4, 8.2, 9) of artificial tear. Amount of the proteins absorbed on the contact lenses were measured by using HPLC. Results: Time to reach the equilibrium of protein adsorption for silicone hydrogel lens was taken longer than hydrogel lens. The amount of adsorbed both lysozyme and albumin at equilibrium were greater for the hydrogel lens than the silicone hydrogel lens, and larger for the ionic lens than the non-ionic lens. Lysozyme was more adsorbed on the higher water content of contact lens, whereas albumin was more adsorbed on the lower water content of contact lens. Only lysozyme was adsorbed on the Group IV hydrogel lens of ionic higher water content. The adsorption of protein on contact lens increased with pH of artificial tears as close to the isoelectric point of each protein. Conclusions: The adsorption amount of lysozyme is more affected by the ionic strength of the contact lens surface than the water content of contact lens. Albumin adsorption is more affected by water content than the ionic strength of the contact lens surface. For the adsorption of proteins on the silicone hydrogel lens, the pore size, determined both by the number of Si atoms and the chemical structure of the silicone-containing monomers, as well as the polarity of contact lens should be also considered.

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

A Correlation Between Vertical Fixation Disparity and Stereopsis at Near (근거리에서 수직주시시차와 입체시와의 관계)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2013
  • Purpose: To investigate a correlation between vertical fixation disparity and stereopsis by analyzing distribution of types of vertical fixation disparity. Methods: In this study, RANDOT(R) stereotest partly using random dot was used in stereopsis tests. The vertical fixation disparity in close proximity categorized fixation disparity slope into six types on the basis of the result of measurement in when two thin lines, one for one eye looks, become overlapped as a line by adding into prism with Wesson fixation disparity card while maintaining a distance of 25 cm from patients. Results: In the types of near vertical fixation disparity curve, targeting 43 people, the first type 55.82% was the most distributed, the second type is the least 23.25%, the third type of 4.65%, the fourth type of 4.65%, the fifth type of 6.98%, the sixths types of 4.65% were distributed. The result of a correlation analysis, which shows the degree of linear correlation between two variables, represented that stereopsis is not correlated with Y-intercept (r = -0.07) which show vertical fixation disparity, associated phoria (r = -0.03) and dissociated phoria (r = -0.00), but it was not statistically significant (p>0.05). Fixation disparity slope of vertical fixation disparity (r = 0.36) was shown to have a positive correlation with stereopsis. It has a low positive correlation and a meaningful statistics (p<0.05). The Y-intercept which indicates vertical fixation disparity was also not associated with stereopsis (r = -0.07) and dissociated phoria (r = -0.03), and this was not statistically significant (p>0.05), while it had a high correlation as well as a statistically significant with associated phoria (r = 0.89). There was a negative correlation between Y-intercept and fixation disparity slope of vertical fixation disparity (r = -0.33). It showed a low relationship but statistically valuable (p>0.05). As a result of regression analysis, the stereopsis was changed as 7.631" if vertical fixation disparity changes 1' and the vertical fixation disparity changed as 0.017' if stereopsis changes 1', and the change was statistically significant (p<0.05). Conclusions: The study shows that there is a low correlation between stereopsis and vertical fixation disparity, and it is difficult to determine stereopsis only using vertical fixation disparity. Therefore, it suggests other factors above vertical fixation disparity have greater influence on stereopsis.