• 제목/요약/키워드: 한계평가법

Search Result 804, Processing Time 0.029 seconds

The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test (디지털 X선 촬영장치의 한계 검사 개선 및 유용성 평가)

  • Gil, Jong-Won;Park, Jeong-Ho;Bae, Seok-Hwan;Hwang, Hye-Jeong;Kim, Yong-Gwon
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.371-379
    • /
    • 2014
  • In this study, we conducted a survey on the limited examinations of the DR system to the 30 radiologic technologists engaging in the clinical sites and university hospitals in Daejeon metropolitan city from Oct. 15, 2012 to Nov. 15, 2012. Based on the survey results, we propose the conceptual design of a supplementary table for the conventional DR system to extend the examination capability and overcome the limitation of DR system. And, we evaluated the convenience and usefulness of the proposed table by applying it to five subjects. Ten experts were involved to evaluate the clinical usefulness of the obtained images. In this study, the experimental results show the feasibility to overcome the limited examination of the conventional DR system, and the proposed supplementary table may be beneficial to patients and hospitals.

Failure Probability Calculation Method Using Kriging Metamodel-based Importance Sampling Method (크리깅 근사모델 기반의 중요도 추출법을 이용한 고장확률 계산 방안)

  • Lee, Seunggyu;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.381-389
    • /
    • 2017
  • The kernel density was determined based on sampling points obtained in a Markov chain simulation and was assumed to be an important sampling function. A Kriging metamodel was constructed in more detail in the vicinity of a limit state. The failure probability was calculated based on importance sampling, which was performed for the Kriging metamodel. A pre-existing method was modified to obtain more sampling points for a kernel density in the vicinity of a limit state. A stable numerical method was proposed to find a parameter of the kernel density. To assess the completeness of the Kriging metamodel, the possibility of changes in the calculated failure probability due to the uncertainty of the Kriging metamodel was calculated.

Estimation Method for Settlements of NC Clays Considering Deformation Modes Under Axis-symmetric Conditions (축대칭 조건하에서의 변형형상을 고려한 정규압밀 점성토 지반의 침하량 평가방법)

  • 김창엽;권오순;정충기
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.7-14
    • /
    • 2001
  • 구조물 하중에 의한 점성토 지반의 침하량을 보다 정확하게 평가하기 위해서는 지반 내의 흙요소가 경험하는 실제적인 응력경로와 이에 따른 변형양상이 적절하게 고려되어야만 한다. 따라서 본 연구에서는 축대칭 조건의 다양한 응력경로를 따라 발생하는 정규압밀 점성토의 변형 거동을 고찰한 기존의 실험적 연구결과를 바탕으로 응력경로법에 근거한 보다 간편하고 합리적인 침하량 평가기법을 제시하였다. 또한 본 연구에서는 제시된 평가기법을 기존의 1차원적인 침하량 평가기법들과 함께 실제와 유사한 조건을 가지는 가상지반의 침하량 산정에 적용해 보았으며, 동일한 조건에 대해 소성모델(MCC 모델)과 혼합압밀이론에 바탕을 둔 유한요소해석을 실시하였다. 그리고 이를 통해 얻어진 결과들을 비교.분석함으로써 기존 평가기법들의 문제점과 한계를 명확히 제시하였으며, 응력증분 평가방법이 침하량 평가에 미치는 영향을 분석하였다.

  • PDF

Comparative Study of Design Methods for Sliding of Perforated-wall Caisson Breakwater (유공케이슨 방파제의 활동에 대한 설계법 비교 연구)

  • Kim, Nam-Hoon;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.5
    • /
    • pp.267-277
    • /
    • 2014
  • The conventional performance-based design method for the solid-wall caisson breakwater has been extended and applied to the perforated-wall caisson. The mathematical model to calculate the sliding distance of a perforated-wall caisson is verified against hydraulic experimental data. The developed performance-based design method is then compared with the conventional deterministic method in different water depths. Both the expected sliding distance and the exceedance percentage of total sliding distance during the structure lifetime decrease with decreasing water depth outside the surf zone, but they increase with decreasing water depth inside the surf zone. The performance-based design method is either more economical or less economical than the deterministic method depending on which design criterion is used. If the criterion for the ultimate limit state is used, the former method is less economical than the latter outside the surf zone, whereas the two methods are equally economical inside the surf zone. However, if the breakwater is designed to satisfy the criterion for the repairable limit state, the former method is more economical than the latter in all water depths.

A Study on the Evaluation of Cleaning Ability Using Optically Stimulated Electron Emission Method (광전자방출(OSEE)법을 이용한 세정성 평가 연구)

  • Min, Hye-Jin;Shin, Jin-Ho;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.95-102
    • /
    • 2008
  • In order to choose alternative environmental-friendly cleaning agents, it is very important in the present point that the systematic selection procedures should be introduced and applied to the industry through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. Thus, a novel cleaning evaluation method utilizing optically stimulated electron emission (OSEE) among various methods of cleaning ability was studied in this study. The contaminants used in this cleaning experiments were flux, solder, grease, cutting oil, and mixed soil of 35% grease and 65% cutting oil. The cleaning agents developed or prepared in our laboratory were employed and their cleaning ability were comparatively evaluated by the OSEE, gravimetry and contact angle methods. The experimental results in this work showed that flux cleaning efficiency measured by the OSEE method was similar to that of the gravimetric method, but that the OSEE method could not be compared with gravimetric method for the case of solder or grease cleaning because the contaminants radiate or absorb ultra-violet light. In case of cutting oil cleaning, the gravimetric method indicated its limitation of cleaning efficiency of cutting oil since it showed cleaning efficiency of 100%, even though residual soil remaining on the substrate surface a little after its cleaning. The comparative experimental results of cleaning ability evaluated by the OSEE- and contact angle measurement methods showed that they were similar in case of cleaning of flux, mixed soil and cutting oil. It was judged that the contact angle measurement method could evaluate the cleaning ability more precisely than the OSEE method for cleaning solder and grease.

  • PDF

An Assessment of Safety Factor for Tunnels Excavated in a Weak Rock Layer (연약 암반층에 굴착된 터널의 안전율 평가)

  • You, Kwang-Ho;Park, Yeon-Jun;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.47-57
    • /
    • 2000
  • It is difficult to calculate factor of safety of a tunnel by applying any analytical method based upon limit equilibrium method since the shape of failure plane in tunnel analysis can not be easily assumed in advance. To cope with this shortcoming, a method is suggested to calculate safety factor of a tunnel by numerical analysis using strength reduction technique. A circular tunnel excavated in a homogeneous rock was selected as an example problem and factors of safety were calculated for no-supported, partly-supported, and completely-supported cases respectively. Meshes with 3 different sizes were examined for a sensitivity analysis. For the verification of the proposed method, a limit equilibrium analysis was conducted and compared with the numerical analysis. The proposed method herein can be used to calculate factor of safety of a tunnel regardless of tunnel shape or geological conditions, and thus can contribute for the improved design and stability assessment of tunnels.

  • PDF

Strain Analysis of Mechanical Structure by Laser Speckle Interferometry (레이저 스페클 간섭법에 의한 구조물의 변형해석)

  • 김경석;강기수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.19-23
    • /
    • 2004
  • 최근 산업의 고도화와 함께 초고온, 방사선노출 등과 같은 극한환경에서 사용되는 구조물과 MEMS 와 같은 미소 구조물(Hicrostructure)이 많아지고 있으며, 이들의 변형해석을 위한 기존의 접촉식 기법들은 그 한계를 극복해야 할 필요가 있다 해결방안으로 레이저를 이용한 비접촉 측정방식이 많은 발전을 해오고 있으며, 특히, 스페클간섭법(Speckle inteferometry)기반의 변형해석 기술이 가장 뛰어난 기술로 인정받고 있다. 스페클간섭법은 컴퓨터 화상처리기술에 힘입어 전자처리 스페클간섭법(Electronic Speckle Pattern Interferometry : ESPI)으로 발전을 하고 있으며, 자동차와 같은 대형구조물의 변형해석에서 MEMS 구조물과 같은 미소구조물 변형해석까지 그 적용범위가 매우 넓다. 본 논문에서는 ESPI 를 이용한 변형해석분야의 국내외 기술현황 및 적응사례, 발전방향를 소개하였다.(중략)

Toxicity Assessment of the Soil by Bioassay Following a Long-Term Application of Sewage Sludge (생물검정법을 이용한 하수슬러지 장기연용 토양의 독성평가)

  • Nam, Jae-Jak;Lee, Seung-Hwan;Kwon, Soon-Ik;Hong, Suk-Young;Lim, Dong-Kyu;Koh, Mun-Hwan;Song, Beom-Hun
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • Bioassay was employed to assess toxicity of soil which had been treated with sewage sludges for seven years. The $Microtox^{(R)}$ and root elongation test of lettuce (Lactuca Sativa.) elucidated that the intensity of soil toxicity was closely related with the types and amount of sewage sludges applied. Both bioassay methods proved to be useful in an assessment of soil toxicity and were consistent to some extent with the conventional chemical analysis methods. $EC_{50}$ values resulted from $Microtox^{(R)}$ were highly correlated with concentration of heavy metals in soils amended with sewage sludges : Cu ($r^2=\;0.86^{**}$), Cr ($r^2\;=\;0.84^{**}$), Ni ($r^2\;=\;0.83^{**}$), and Zn ($r^2\;=\;0.69^{**}$). This demonstrated that both bioassay techniques could be employed as tools for soil toxicity assessment when the soil was exposed to solid wastes such as sewage sludge.

Evaluation of Discomfort Glare Indices in Office Lighting (사무실 조명에서의 Discomfort Glare 계산법 적용 및 평가)

  • Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.13-21
    • /
    • 2002
  • In the interior lighting, usually we refer to TAL and general lighting. The last one is that we generally adopt it in the interior lighting conditions. Here, glare is most important factor of them, especially in working place using VDT. Reference or development of estimation on glare has been studied in CIE, IESNA etc. and these of glare regulations now are applied differently in the interior lighting design or estimation on glare. But we have no glare regulation in detail, of course except G classification, which has limit of itself, so in my case it is impossible to apply in the interior lighting. On this paper, with some of main glare regulations in the world and our conditions in the interior lighting which are selected carefully, in an actual state it has been estimated So, it intended to blow which one is most suitable or what factors are considered of them, also show glare index which are appropriate to our interior lighting.

Development and Validation of Analytical Method and Antioxidant Effect for Berberine and Palmatine in P.amurense (황백의 지표성분 berberine과 palmatine의 분석법 개발과 검증 및 항산화 효능 평가)

  • Jang, Gill-Woong;Choi, Sun-Il;Han, Xionggao;Men, Xiao;Kwon, Hee-Yeon;Choi, Ye-Eun;Park, Byung-Woo;Kim, Jeong-Jin;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.544-551
    • /
    • 2020
  • The aim of this study was to develop and validate a simultaneous analytical method for berberine and palmatine, which are representative substances of Phellodendron amurense, and to evaluate the antioxidant activity. We evaluated the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of analytical methods for berberine and palmatine using high-performance liquid chromatography. Our result showed that the correlation coefficients of the calibration curve for berberine and palmatine exhibited 0.9999. The LODs for berberine and palmatine were 0.32 to 0.35 µg/mL and the LOQs were 0.97 to 1.06 µg/mL, respectively. The inter-day and intra-day precision values for berberine and palmatine were from 0.12 to 1.93 and 0.19 to 2.89%, respectively. The inter-day and intra-day accuracies were 98.43-101.45% and 92.39-100.60%, respectively. In addition, the simultaneous analytical method was validated for the detection of berberine and palmatine. Moreover, we conducted FRAP and NaNO2 scavenging activity assays to measure the antioxidant activities of berberine and palmatine, and both showed antioxidant activity. These results suggest that P.amurense could be a potential natural resource for antioxidant activity and that the efficacy can be confirmed by investigating the content of the berberine and palmatine.