• Title/Summary/Keyword: 하중크기

Search Result 1,204, Processing Time 0.027 seconds

Thrust Estimation Acting on Rotor of LOX Pump for Liquid Rocket Engine (액체로켓엔진용 산화제펌프 회전체의 하중 예측)

  • Kim, Dae-Jin;Choi, Chang-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.6
    • /
    • pp.98-104
    • /
    • 2015
  • Excessive thrust acting on the rotor of pump can cause the damage of pump or the decrease of pump lifetime. Therefore, for ensuring the safety of LOX pump of a liquid rocket engine, the thrust of pump rotor is estimated by similarity tests. Axial thrust is indirectly measured by an axial thrust measurement unit positioned outside pump. Radial thrust is calculated based on pressure distribution of volute scroll. As a result, axial and radial thrust are increased when the flowrate of pump decreases. However, both thrusts do not affect the stability of pump rotor since their values are not large.

Analysis on Reactions of Full-Scale Airframe Static Structural Test (항공기 전기체 정적구조시험의 반력 분석)

  • Shim, Jae-yeul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.3
    • /
    • pp.195-205
    • /
    • 2020
  • This study addresses analysis on reactions which are induced in restraint system for airframe full-scale static structural test. This system restraints 6 degrees of freedom of a test article. It is valuable to study evaluating test error through analysis on the reactions which include all errors in a test. It is required to calculate fistly right reactions for the evaluation. This study focuses on calculation of the right reactions. The reaction is represented by sum of nominal reaction(Rn) and testing error reactions(Rce, Rerr) and is analyzed by two steps (inital vs relative reaction) in this study. It would evaluate intrinsic error at 0%DLL and error induced from applying test load, separately. Based on analysis using test data of a full-scale static test(canard type aircraft), resultant force of Rces and Rce_rs are distributed within 82.8N while resultant force of Rerr_rs shows to increase upto max. 808N as load level increment. Such well distribution of the Rce within the small range is caused from TMF values characteristics which are well distributed within -30N~40N. Additionally, it is shown through qualitative analysis on three components(X0, Y0, Z0) of the relative reaction(Rerr_r) that the reactions must be calculated with considering deformation of test article to calculate correctly reactions. This study shows also that equations characterizing deformation of components of test article are required to calculate the correct reactions, the equations must include information which will be used to calculate movement of all loading points.

Maximum Shear Modulus of Sand - Tire Chip Mixtures under Repetitive KO Loading Conditions (반복하중 재하 시 모래-타이어칩 혼합토의 최대전단탄성계수 변화)

  • Ryu, Byeonguk;Park, Junghee;Choo, Hyunwook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.41-50
    • /
    • 2021
  • This study investigated the changes in engineering characteristics of sand-tire chip mixtures during repetitive loading. To quantify the changes in the maximum shear modulus according to the tire chip content in the mixtures and the particle size ratio between sand particle and tire chip, the samples were prepared with tire chip content of TC = 0, 10, 20, 40, 60, and 100%, and the particle size ratios SR were also set to be SR = 0.44, 1.27, 1.87, and 4.00. The stress of the prepared sample was applied through a pneumatic cylinder. The experiment was conducted in the order of static loading (= 50 kPa), cyclic loading (= 50-150 kPa), static loading (= 400 kPa) and unloading. The stress applied to tested mixtures was controlled by a pressure panel and a pneumatic valve by using an air compressor. The shear wave velocity was measured during static and cyclic loadings by installing bender elements at the upper and lower caps of the mold. The results demonstrated that the change in maximum shear modulus of all tested materials with varying SR during repetitive loading is the most significant when TC ~ 40%. In addition, the mixture with smaller SR at a given TC shows greater increase in maximum shear modulus during repetitive loading.

Size Effect on Axial Compressive Strength of Concrete (콘크리트의 축압축강도에 대한 크기효과)

  • 이성태;김민욱;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.153-160
    • /
    • 2001
  • In this study, the size effect on axial compressive strength for concrete members was experimentally investigated. Experiment of mode I failure, which is one of the two representative compressive failure modes, was carried out by using double cantilever beam specimens. By varying the eccentricity of applied loads with respect to the axis on each cantilever and the initial crack length, the size effect of axial compressive strength of concrete was investigated, and new parameters for the modified size effect law (MSEL) were suggested using least square method (LSM). The test results show that size effect appears for axial compressive strength of cracked specimens. For the eccentricity of loads, the influence of tensile and compressive stress at the crack tip are significant and so that the size effect is present. In other words, if the influence of tensile stress at the crack tip grows up, the size effect of concrete increases. And the effect of initial crack length on axial compressive strength is present, however, the differences with crack length are not apparent because the size of fracture process zone (FPZ) of all specimens in the high-strength concrete is similar regardless of differences of specimen slenderness.

Pile and adjacent ground behaviors depending on horizontal offset between pile and tunnel subjected to horizontally loaded single pile (수평하중을 받는 단일 말뚝 하부 터널굴착 시 말뚝-터널 수평이격거리에 따른 말뚝 및 인접 지반 거동)

  • Ahn, Ho-Yeon;Oh, Dong-Wook;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.685-703
    • /
    • 2017
  • Recently, as the number of high-rise building and earthquake occurrence are increasing, it is more important to consider horizontal load such as wind and seismic loads, earth pressure, for the pile foundation. Also, development of underground space in urban areas is more demanded to meet various problem induced by growing population. Many studies on pile subjected to horizontal load have been conducted by many researchers. However, research regarding interactive behavior on pile subjected to horizontal load with tunnel are rare, so far. In this study, therefore, study on the behaviors of ground and horizontal and vertical loads applied to single pile was carried out using laboratory model test and numerical analysis. The pile axial force and ground deformation were investigated according to offset between pile and tunnel (0.0D, 1.0D, 2.0D: D = tunnel diameter). At the same time, close range photogrammetry was used to measure displacement of underground due to tunnelling during laboratory model test. The results from numerical analysis were compared to that from laboratory model test.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load (표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Kim, Duhwan;Jin, Hyunsik;Seo, Seunghwan;Park, Jaehyun;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.119-128
    • /
    • 2018
  • Limit state design has been implemented in Korea since 2015; however, there exists no specification of lateral load determination on retaining wall due to the Korean standard traffic load on retaining wall's backfill surface. The lateral load from traffic depends on lane number, standard truck's axle loads and locations, loading distance from the inner wall. The concept of equivalent height of soil accounting for traffic loadings is typically used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the Korean standard truck, based on the findings from analytical solutions using Bounessq's theory and numerical assessment using 2D finite element method. Consequently, it was found that the equivalent heights of soil from the Korean standard truck load were lower for lower retaining wall height.

Lateral Behavior of Driven Piles Subjected to Cyclic Lateral Loads in Sand (모래지반에서 반복수평하중을 받는 항타 말뚝의 수평거동)

  • Paik, Kyu-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.41-50
    • /
    • 2010
  • The behavior of laterally cyclic loaded piles is different from that of piles under monotonic loading and depends on soil and load characteristics. In this study, model pile load tests were performed using a calibration chamber to investigate the effects of load characteristics on the behavior of laterally cyclic loaded piles in sand. Results of the model tests show that the ultimate lateral load capacity of laterally cyclic loaded piles decreases linearly with increasing the number of cycles and increases slightly with increasing the magnitude of cyclic lateral loads. When the piles reach the ultimate state, the maximum bending moment developed in the piles decreases linearly with increasing the number of cycles and it occurs at a depth of 0.36 times pile embedded length for all the number of cycles. However, both the magnitude and depth of the maximum bending moment of piles in the ultimate state increase slightly as the magnitude of cyclic lateral loads increases. It is also observed that the cyclic lateral loading generates a decrease in the ultimate lateral load capacity and maximum bending moment for piles in the ultimate state. In addition, based on the model test results, a new empirical equation for the ultimate lateral load capacity of laterally cyclic loaded piles in dense sand is also proposed. A comparison between predicted and measured load capacities shows that the proposed equation reflects satisfactorily the model test results.

Capability of force standards at KRISS (한국의 힘표준 능력)

  • 강대임;박연규;김종호;김민석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.7-11
    • /
    • 2004
  • 일상생활과 산업현장에서 측정되는 힘의 범위를 정리해 보면 Fig. 1 과 같다. 힘의 SI 단위인 1뉴턴(N : 단위 질량 1 kg에 대해 1$m/s^2$ 의 가속도를 생기게 하는 힘의 크기임 정성적으로는 사과 반쪽을 손에 들고 있을 때 느끼는 중력의 크기가 약 1 N임)을 기준으로 크게는 수십 MN($10^{6}$ N) 크기의 우주선에서 발생하는 추진력에서부터 작게는 수 PN($10^{-12}$ N) 크기의 원자들 사이의 결합력까지 그 범위가 매우 광범위하다.

The Influence of the Loading Sizes on Natural Frequency of the Advanced Composite Material Structures (복합신소재구조물의 고유진동수에 대한 하중크기의 영향)

  • Han, Bong Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.20-27
    • /
    • 2013
  • Simple Iteration Method for calculating the natural frequency is presented in this paper. This method is simple but exact method of calculating natural frequencies corresponding to the modes of vibration of beams and tower structures with irregular cross sections and arbitrary boundary conditions. This method consists of determining the deflected mode shape of the member due to the inertia force under resonance condition. Finite difference method is used for this purpose. The influence of the $D_{22}$ stiffness on the natural frequency is rigorously investigated. In this paper, the influence of the loading sizes, different cross section on the natural frequency of vibration of some structural elements is presented. This method extends to two dimensional problems including advanced composite material structures.

Fire Risk Assessment of Temple Components in Young-dong Areas using Fire Loads (영동지역 사찰의 구성요소별 화재하중을 통한 화재위험성 평가)

  • Lee, Hae-Pyeong;Kim, Su-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.71-75
    • /
    • 2010
  • In this study, we have assessed the fire risk of Buddhist temples located in Youngdong area by means of fire loads of components. First, we categorized the components into Buddhist temples (Dae-Ung-Jeon, Pal-Sang-Jeon), Sam-Seong-Gak (Chil-Seong-Gak, San-Sin-Gak), a Buddhist temple dormitory (Sim-Geom-Dang, Seol-Seon-Dang), Lu, Il-Ju-Mun and then carried out a field survey. Then, we examined the area of each room, types as well as quantity and dimension of combustibles. The fire loads calculated in this way were 446.96 $kg/m^2$ for Buddhist temples, 331.71 $kg/m^2$ for Sam-Seong-Gak, 164.14 $kg/m^2$ for the Buddhist temple dormitory, 463.91 $kg/m^2$ for Lu and 1042.14 $kg/m^2$ for Il-Ju-Mun, thus showing Il-Ju-Mun with the biggest fire load. We speculate that this is because construction materials were similar in size and quantity to others albeit the area of Il-Ju-Mun is smallest.