• Title/Summary/Keyword: 하우스

Search Result 1,920, Processing Time 0.031 seconds

A Case Study on Metadata Management for User Access to Data Warehouse - Suggestions about metadata management using K-bank case - (사용자의 데이터 웨어하우스 접근과 활용을 위한 메타데이터 관리 사례 - K 은행 사례를 통한 메타데이터 관리의 시사점 -)

  • Kim, Gi-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.225-233
    • /
    • 2007
  • This paper uses the taxonomy of 3 metadata schema(extraction metadata, warehouse, metadata, and user access metadata) to investigate how to manage metadata and what metadata to manage in data warehouse. In particular, this paper focuses on two kinds of metadata(warehouse metadata and user access metadata) and studies a case about metadata management in a real business world

  • PDF

Development of Simulation Model for Greenhouse Heating System Using Latent Heat Storage System (잠열축열을 이용한 그린하우스 난방시스템의 시뮬레이션 모델개발)

  • 노정근;송현갑
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.31-33
    • /
    • 2001
  • 잠열축열 그린하우스 난방 시스템의 난방특성을 분석하기 위하여 이에 대한 열평형 이론을 정립하고 수치해석에 의하여 컴퓨터 시뮬레이션 모델을 개발하고자 잠열축열 그린하우스 난방 시스템의 열저항 회로망을 구성하였다. 그리고 그린하우스의 피복재, 내부 공기, 토양표면, 잠열 축열재와의 열평형 방정식을 구성하였으며, Newton-Raphson반복법을 이용하여 수치해석을 하였고, 실험 분석을 통하여 수치해의 타당성을 검증하였다. 시뮬레이션 모델을 위하여 C언어를 사용하였으며, 겨울철 (11월-2월)의 기후 조건이 유사한 여러 날을 선정하여 온도, 태양강도, 상대습도, 토양 수분함량 등을 자료로 하여 모델링을 하였다. 여기에 사용된 토양 조건은 사양토로 건조한 상태를 유지하였다. 이상과 같은 분석에 의하여 그린하우스내 경시적 공기온도 변화와 열전달 현상의 실험치와 이론분석 결과가 잘 일치하고 있음을 알 수 있었다.

  • PDF

An Extension of DBMax, Oracle Performance Monitoring Tool, for Data Warehouses (데이터웨어하우스 성능 모니터링을 위한 DBMax의 확장)

  • 김은주;용환승;이상원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.262-264
    • /
    • 2002
  • 데이터웨어하우스는 대용량의 데이터를 대상으로 복잡한 분석을 수행하거나 전략적 의사 결정을 위해 사용되기 때문에 신속한 질의 응답을 위한 성능 관리가 무엇보다 중요하다. 데이터웨어하우스는 일반 운영계 시스템과는 다른 목적과 특성을 가지기 때문에 그에 적합한 성능 모니터링 방법이 필요하다. 본 연구에서는 오라클 데이터베이스를 위한 OLTP(On-Line Transaction Processing)용 국산 성능 모니터링 도구인 DBMax를 데이터웨어하우스 환경에 적용할 수 있도록 기능을 확장한다. 우선 기존의 운영계 시스템과는 구분되는 데이터웨어하우스의 특성을 토대로 오라클9i에서 제공하고 있는 성능 항상 기법인 실체화된 뷰(MV: Materialized View)와 EH(Data Extraction, Transformation and Loading) 화장 기능을 모니터링하기 위한 요구사항을 분석하고 이를 지원하기 위한 DBMax 확장 방안을 설계 및 구현한다. 실체화된 뷰와 ETL 확장 기능을 위해 제공되는 오라클9i의 다양한 스키마 객체에 대한 정보 및 성능 관련 지표를 제시하여 SQL 튜닝 기능을 지원하며 사후 분석을 위한 DBMax의 로그 파일에서 의미 있는 SQL문을 추출하여 잠재적으로 유용한 실체화된 뷰를 권고할 수 있도록 기능을 확장한다.

  • PDF

A Strategy for a Maintaining Client-based Web House (클라이언트 기반 웹하우스 유지 전략)

  • 이혁민;김경창
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.94-96
    • /
    • 2002
  • 본 논문에서는 기존치 서버 기반 데이터 웨어하우스 유지 전략에 대한 문제점들을 해결하기 위해 클라이언트 기반 웹 하우스 유지 전략을 제시한다. 소스 시스템에서 데이터 갱신이 발생했을 경우 브라우져 모니터를 통해 자동적으로 웹하우스에 실시간 반영하도록 하여 모든 사용자 요청을 서버에서 처리하는 부담을 줄이고 사용자가 많더라도 웹하우스 시스템의 처리부담을 최소화할 수 있도록 클라이언트에서는 결과 데이타 재사용/질의 재생성을 사용하여 서버의 자원 사용을 최소화 할 수 있도록 하였다. 모든 클라이언트 프로그램은 자동적으로 설치되고 관리되므로 프로그램이 변동되더라도 쉽게 유지될 수 있으며 소스 시스템에는 어떠한 처리 부담도, 어떠한 프로그램도 설치하지 않기 때문에 실제 비즈니스 현실에서 적용하기가 용이하다.

  • PDF

A Technology of Greenhouse Management System based on USN (USN 기반의 그린하우스 관리 기술)

  • Rhee, Inbaum;Jeon, Byeong-chan;An, Young-chang;Lee, Jong-kyo;Bae, Tae-hyun;Park, Ju-hee;Ryu, Daehyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.1162-1165
    • /
    • 2011
  • 본 연구는 그린하우스 내의 환경 정보를 원격 감시 및 제어함으로써, 재배의 편리성을 확보하는 한편, 수집된 정보에 대하여 데이터베이스를 구축하여 작물 재배의 최적 환경을 도출하는 데 그 목적이 있다. 이를 위해서, 2연동 그린하우스 제작하여, 그린하우스를 내에 여러 종류의 센서와 카메라를 장착하였으며, 이를 통해서 감지되는 정보를 원격에서 수집, 자료화 하였다. 사용자 편의를 위하여 웹페이지를 개설, 실시간으로 정보의 검색과 제어가 가능하게 하였으며, 모바일에서도 일부 기능 구사가 가능하도록 하였다. 정보의 수집과 전달, 사용자에 의한 그린하우스 환경제어와 관련한 모든 기능에 대한 안정성을 장시간 현장시험을 통해서 실험적으로 확인하였다. 이 시스템은 그린하우스를 설치하여 작물을 재배하는 농가에 편리를 제공하여 시간적, 공간적 제약에서 많은 융통을 부여할 것이다. 또한 공장, 사무실, 가정 등 유사한 환경 시설에 대해서 확대 적용하는 것이 가능할 것이다.

Indepth Study of Numerical Heat Transfer and Fluid Flow for Energy Saving of Greenhouse (시설하우스 에너지 절감을 위한 열유동 수치 해석 심층 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Choi, Jun-Ho;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.466-471
    • /
    • 2007
  • The purpose of study is to obtain basic but important information for the operation of the greenhouse facility located in the suburb of town. Special emphasis is given on the aspect of energy saving method, which can be easilyapplicable in a practical sense. For this end numerical calculation has been made systematically in order to increase the energy efficiency by the evaluation of the temperature distribution in greenhouse. Major parameters considered are primarily the overall shape of greenhouse together with the various conditions of baffle installion inside greenhouse. Further, the performance of heating system is also carefully compared each other for a number of typical arrangements of heating duct. The performance of the computer program developed in this study is evaluated by the observation of the famous fluid trapping phenomenon occurred in staggered baffle condition in the enclosure of greenhouse. Based on the this study, a number of useful conclusions can be drawn, that is, the installation of baffles are quite effective in energy saving method with a minor modification of facility. Also, it is found that the change of the heating duct system can contribute significantly to the uniform temperature distribution in greenhouse. Further other findings obtained by numerical calculation were not only physically consistent and meaningful but also useful for the determination of optimum condition of practical operation of greenhouse.

Development of Multi-span Plastic Greenhouse for Tomato Cultivation (토마토 재배용 연동 플라스틱 온실 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.428-436
    • /
    • 2012
  • This study aimed to develop the multi-span plastic greenhouse which is suitable for tomato cultivation and is safe against climatic disasters such as typhoon or heavy snow. The width and heights of eaves and ridge of newly developed tomato greenhouse are 7, 4.5 and 6.5 m, respectively. The width is the same but the eaves and ridge heights are 1.8 and 2 m higher than conventional 1-2 W greenhouses, respectively. Cross beam has been designed as a truss structure so it can sustain loads of tomato and equipment. Tomato greenhouse has been designed according to climatic disaster preventing design standard maintaining the high height. In other words, the material dimensions and interval of materials including column and rafter have been set to stand against $40m{\cdot}s^{-1}$ of wind and 40 cm of snow. Tomato greenhouse has been equipped with rack-pinion type roof vents which have been used in glass greenhouse in order to prevent excessive rise in air temperature. This vent type is different from that of 1-2 W type greenhouse which is made by rolling up and down the vinyl at upper part of column. Roof vents are installed at ridge, and thus external air inflow and natural ventilation are maximized. As the height increases, heating cost increase as well and, therefore, tomato greenhouse has been equipped with multi-layered thermal curtain, of which thermo-keeping is excellent, to prevent heat from escaping.

Automatic Control System of Vertical Agitation Heater for Controlling Temperature of Greenhouse (시설하우스 온도 조절을 위한 수직형 교반 히터 자동제어 시스템)

  • Kwak, Yun-Ah;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.623-628
    • /
    • 2015
  • As the current heating control of the greenhouse is located in specifically designed place, there is an inevitable difference in degrees depending on the latitude in it. Even though it is necessary to maintain the proper temperature in the greenhouse producing vegetables and fruit plants, the difference between ups and downs in the facilities results in the increasing energy consumption to both warm and cool down the facilities. The newest heating method, automatic control system of vertical agitation heater, which manipulates the inner air circulation efficiently, is suggested in this paper. The proposed system utilizes both the upper temperature and the lower temperature, and controls the air circulation fan and heating independently, so that maximizes the efficiency of heating with the minimum energy and implements predictable planning of farm products.

Analyzing the Impact for Housing Occupied Form of HouseNomad ('하우스노마드족'의 주거점유형태에 미치는 요인 분석)

  • Yun, Jin-Young;Oh, Jongryul
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.955-963
    • /
    • 2014
  • According to the "Population and Housing Census of 2010", announced by the National Statistical Office, "House Nomad group" was increased by more than 70% compared to 2005. Emergence of House Nomad tribe about the cause of the increase of influence and House Nomad tribe give the housing market, but prior to the discussion often, there is no place that still it became clearly evident in the research. The purpose of this study, are looking for the emergence and increasing cause of House Nomad group in terms of consumption behavior of the house. For this reason, We use the Population and Housing Census 1% of the data 2010. and Multinomial Logit Models., is a useful method that can be utilized when there is no rank and order the consumer choice. The results were as follows. House Nomad group was found to be higher probability of living place and good environmental characteristics of housing that has been expressed in the properties of the housing. Also appeared to have a relatively longer time commuting. And that residential mobility is high.

Survey on the Concentration of Sulphur Dioxide Gas in the Plastic Film House Cultivation (시설(施設) 하우스내 아황산(亞黃酸)(SO2)가스 발생현황(發生現況) 조사(調査))

  • Kim, Bok-Young;Lee, Jong-Sik;Jung, Goo-Bok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.4
    • /
    • pp.357-360
    • /
    • 1997
  • To fine out the concentration of $SO_2$ gas in plastic film house, the survey was conducted at 343 sites throughout the nation. The $SO_2$ concentration in plastic film house were similar both heating and non-heating, but $SO_2$ cocentration higher than 0.8ppm was detected at those with heating. The $SO_2$ concentration in plastic film house cultivated red-pepper higher than those of cucumber or tomato cultivation, and it was produced higher amounts at day time than night due to the higher temperature. In plastic film house with heating, $SO_2$ was leaked at brocken parts of heater and joint of stove pipe, sometimes, $SO_2$ discharged from smokestack was resucked with air. $SO_2$ concentration in the plastic film house with and without ventilation were 0.2 and 0.6ppm, respectively.

  • PDF