• Title/Summary/Keyword: 하악 피개의치

Search Result 63, Processing Time 0.119 seconds

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Technique for fabricating a mandibular suction denture with a plastic implant tray (임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법)

  • Lee, Ju-Hyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Even though implant overdentures are preferentially recommended to mandibular edentulous patients, many patients may select conventional complete dentures due to cost and general condition. Proper retention and stability of conventional complete dentures in patients with severe alveolar bone resorption is difficult to achieve. To overcome the limitations, mandibular suction dentures with the closed mouth impression technique have been used. However, the previous technique requires the Frame cut back tray, the Centric tray, and the Gnathometer M. This article introduces a technique for fabricating a mandibular suction denture with common dental materials.

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker (하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고)

  • Park, Eun-Chul;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.378-386
    • /
    • 2015
  • Overdenture has the advantage of improving the stability and retention of the denture but the abutment may be easily affected by caries or periodontal disease and the thin denture can be easily broken. The magnetic attachment overdenture has a high vertical retention but a low horizontal retention, thus, exerting a less disruptive force to the abutment or implant and shows less abrasion or damage compared to other mechanical retainers. Denture fractures in overdenture is caused by the thin denture base as the attachment is inserted, but it may also be caused by the difference in detrusion between soft tissue and hard tissue, and between an implant and a natural tooth. To compensate this shortcoming, a magnetic attachment with a silicone ball inserted in the magnet was developed as we report a successful case using this specific type of magnetic attachment overdenture.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.

Implant Supported Overdenture using Locator® System on Edentulous Patient (완전 무치악 환자에서 Locator® system을 이용한 임플란트 피개의치 수복 증례)

  • Lee, Sang-Yeob;Shin, Sooyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.351-359
    • /
    • 2008
  • It is difficult to provide prosthodontic treatment to fully edentulous patients with severe alveolar bone resorption, because this makes patents hard to endure functional load, and to adapt to the dentures, which result in emotional stress to patients. Implant supported overdenture can be chosen to solve these problems. Among several types of them, the implant retained and tissue supported overdenture, is available to the patients of low masticatory force with the reduced cost. Attachments also can be used for increasing retention and esthetics in dentures. Especially, $Locator^{(R)}$ system needs a small vertical interarch space for restoration and is able to compensate the difference of angle between fixtures. In this study, we restored maxilla with conventional complete denture, and mandible with implant and tissue supported overdenture and $Locator^{(R)}$ system.

Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report (하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Min-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Jo, Yong-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2022
  • Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.

The use of implant-assisted removable partial denture in the partially edentulous maxilla with a few unilateral remaining teeth and implant overdenture in the mandible: A case report (상악 편측 소수 잔존치에서 임플란트 융합 국소의치와 하악 임플란트 피개의치의 수복 증례)

  • Yun, Yina;Kim, Hyun-Ah;Park, Sangwon;Park, Chan;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.515-522
    • /
    • 2021
  • Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.