• Title/Summary/Keyword: 하수

Search Result 3,828, Processing Time 0.031 seconds

Evaluation of Numerical Experiment of Pollution Dispersion on the Sewer Crack Occurrence (하수관거 균열발생에 따른 오염확산의 수치실험 평가)

  • Park, Jaesung;Bae, Wooseok;Lee, Hojin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • Because sewer is embedded in land, the pollutant permeating to underground so fast can cause contamination of soil when crack of sewer occurs. In this study, numerical modelling on dispersion of pollutant at sewer crack was performed. Based upon the study, the following conclusions were obtained. It was shown that transfer direction of pollutant was similar to the flow with topography slope of surface. It was exposed that the pollutant permeated to 8~10m depth. It is expected to offer efficiency in sewer management in the future through this research.

  • PDF

Design of sewage facility monitoring system using IoT technology in mobile device environment (모바일 디바이스 환경에서 IoT 기술을 활용한 하수시설 모니터링 시스템 설계)

  • Kwon, Young-Woo;Jeon, Young-joon;Jang, Si-Woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.86-88
    • /
    • 2018
  • 스마트시티 개념의 등장과 함께 국민의 삶의 질에 대한 정부의 관심이 증가하고 있다. 국민의 삶의 질을 향상시키는 것은 하수도와 같은 도시기반시설이며, 정부에서는 이를 지속적으로 유지관리 하여 주거환경 개선, 공중위생관리, 침수방지 등을 위해 노력하고 있다. 최근에는 하수시설의 노후화 와 서비스 범위의 변화에 따른 하수 서비스 품질에 대해 국민적 관심이 증가하고 있다. 또한 급격한 기후변화에 따른 도시 침수와 같은 재해가 빈번하게 발생함에 따라 재난 관리 측면에서도 하수도는 매우 중요한 비중을 차지하고 있다. 본 논문에서는 모바일 디바이스와 IoT 기술을 활용하여 하수시설 모니터링 시스템을 설계하였다. 제시하고 있는 시스템은 하수시설의 데이터를 수집하고 모바일 어플리케이션을 통해 사용자에게 알려준다.

  • PDF

열정! 건설현장을 찾아서 - 철저한 안전관리로 쾌적한 안전도시 춘천 조성, 코오롱글로벌 춘천시 하수관거정비 임대형민자사업현장

  • Yeon, Seul-Gi
    • The Safety technology
    • /
    • no.182
    • /
    • pp.16-18
    • /
    • 2013
  • 강원도 춘천시에 최근 새로운 변화의 바람이 불고 있다. 우 오수관로를 신설하고 재정비함으로써 하수관거의 기능을 개선하고 하수처리장의 운영효율을 증대시키는 공사가 대대적으로 펼쳐지고 있는 것이다. 2015년 1월, 이 사업이 완료되면 춘천시는 방류 수역 수질개선으로 악취가 저감되고 쾌적한 환경이 조성되는 등 지역주민의 생활환경이 크게 개선되는 효과를 얻을 수 있다. 더불어 효율적인 하수관 유지보수체계도 구축할 수 있게 된다. 사실상 더욱 살기 좋은 춘천시의 등장이 임박한 것이다. 이런 행복한 변화를 만들어내고 있는 주인공은 바로 '코오롱글로벌'이다. '코오롱글로벌 춘천시 하수관거정비 임대형민자사업현장'은 춘천시를 전국 제일의 행복도시로 만들겠다는 신념으로 시공에 임하고 있다. 때문에 공사의 품질을 좌우하는 '안전'에 만전을 기하고 있다. 철저한 안전관리를 통해 춘천을 최고의 주거환경을 갖춘 도시로 변화시키고 있는 이곳 현장을 찾아가 봤다.

  • PDF

하수처리 프로세서 제어를 위한 감시제어 시스템

  • 김현기;오성권;황희수;우광방
    • 전기의세계
    • /
    • v.39 no.6
    • /
    • pp.67-75
    • /
    • 1990
  • 하수처리 프로세스의 과제로는 우수침수, 수질보존, 자원의 유효이용이 그 주요내용이다. 이에 대응하기 위해 기상, 우량, 하천정보 시스템의 구성, 지식공학응용 우수펌프 운전제어, 하수의 고도처리기술 등의 방법이 행해지고 있다. 하수도는 생활환경의 개선, 침수의 방지, 공공 용수 지역의 수질보존의 측면뿐만 아니라 최근에는 하수도를 자원으로써 이용하는 관점으로부터 시서르이 공간이용, 처리수 및 슬러지의 다목적 활용도 중요한 과제로 되고 있다. 하수도 plant의 전기, 계장 기술을 구성하는 요소 기술은 전기(E), 계장(I), computer(C) 관계하는 기술을 종계로써 하고, 시스템설계로부터 시공까지의 engineering기술을 횡계로 한 통합 시스템 기술이다. 하수도 분야에 있어서의 감시제어 시스템은 종래의 계층화된 수직분산 방식에 덧붙여 계층마다 기능을 나누어 수평분산방식이 진행되고 있고, 최근에는 수직분산, 수평분산의 감시제어 시스템으로 이행하고 있다.

  • PDF

Impact Analysis and Prioritization of Wastewater Reuse (안양천유역별 하수처리수 재이용에 대한 효과 분석 및 우선순위 선정 개발)

  • Jun, Sang-Mook;Chung, Eun-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.627-627
    • /
    • 2012
  • 본 연구의 목적은 수문학적 분석과 다기준의사 결정을 사용한 계획 구성을 통한 하수처리수 재이용의 실현성을 보여주는데 있다. 안양천의 10개의 소유역을 대상으로 BOD와 유량에 대한 대안을 세워보았다. BOD는 각 유역에 3.0 mg/L 와 4.7 mg/L로 선정하였고 유량은 각 소유역에 따라 대안을 선정하였다. 대안에 따른 수문학적 분석은 Hydrological Simulation Program in Fortran (HSPF)을 사용하였다. 본 연구에서는 수질이 향상되고 요구되는 유량만킁의 증가가 있다면 하수처리수 재이용이 파괴된 물 순환의 회복에 얼마나 큰 영향을 미치는지에 대해 보여주었다. 추가적으로 대안의 우선순위를 선정하는데 있어서 다음의 세가지 경우을 비교하였다: 1) 물의 유량과 수질의 영향 그리고 2) 현재 나타나고 있는 유량과 수질의 수문학적 취약점에 대한 고려 마지막으로 3) 사회와 경제적인 측면에서 고려하였는지에 대해 비교하였다. 그 결과 세 가지 경우는 매우 다른 순위를 나타냈다. 그러므로 하수처리수 재이용에 대한 다양한 영향에 대한 고려사항은 유의 깊게 선택 되어야 하겠다.

  • PDF

Control strategy of primary clarifier operation in wastewater treatment plant during rainfall inflow (초기강우 유입 시 하수처리시설 일차 침전지 운전제어 전략)

  • You, Kwang Tae;Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.11
    • /
    • pp.947-950
    • /
    • 2019
  • The main feature of this paper is to provide a driving control strategy to improve the primary clarifier treatment efficiency in the initial rainfall inflow. With the recent development of IoT technology and sensing technology, the basis for operation control of wastewater treatment facilities has been improved. As a result of improving the efficiency of treatment of primary clarifier using on-line measurement results, it is possible to minimize the outflow of untreated sewage and contribute to the improvement of operation efficiency of wastewater treatment plants.

Effect Analysis of Alternatives to Secure Instream Flow in the Anyangcheon Using HSPF (HSPF를 이용한 안양천의 유지유량 확보 방안에 대한 효과 분석)

  • Lee, Kil-Seong;Lee, Joon-Seok;Chung, Eun-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1840-1844
    • /
    • 2006
  • 현재 안양천 유역에서는 하천 유지유량 확보 및 건천화 방지를 위해 지하철 용출수, 하수처리장 방류수 및 재이용수가 활용되고 있다. 본 연구에서는 광범위한 유역에 적용이 가능하고, 점오염원 및 비점오염원 분석과 처리 대안의 효과 분석을 실시할 수 있는 HSPF (Hydrological Simulation Program - Fortran) 모형에 대해 민감도 분석을 실시한 후 안양천 중상류 유역에서 현재 활용되고 있는 유지유량 확보 방안에 대한 효과 분석을 수행하였다. 총유출량과 첨두유량에 대한 매개변수 민감도 분석 결과 AGWRC, DEEPFR, INFILT, LZSN, UZSN, IRC, INTFW, LZETP 순으로 민감하게 반응하였으며, 이 중 유출에 1% 이상 변화를 주는 매개변수 AGWRC, DEEPFR, INFILT, LZSN, UZSN, IRC를 모형의 보정 및 검증에 사용하였다. HSPF 모형을 이용하여 2004년 안양천 유역을 모의한 결과 갈수량 기준 시 안양천 중류 유량의 82%가 안양하수처리장에서 방류되는 방류수에 의한 것으로 나타났으며, 하수처리 재이용수와 지하철 용출수는 각각 4.6%와 1.3%의 영향을 보였다. 따라서 안양천 유역과 같은 건천화가 진행되고 있는 도시하천의 경우 지하철 용출수 및 하수처리수 등의 하천 유지유량 확보 방안은 물순환 건전화의 중요한 대안이 될 수 있을 것이다.

  • PDF

A Kinetic Studies of Pyrolysis and Combustion of Sewage Sludge (하수 슬러지의 열분해 및 연소 Kinetics 연구)

  • Roh, Seon Ah
    • Resources Recycling
    • /
    • v.23 no.6
    • /
    • pp.47-53
    • /
    • 2014
  • Effective treatment and energy conversion technologies are necessary due to the ban of the dumping of organic waste including the sewage sludge. In this study, the kinetics of pyrolysis and combustion were derived in a TGA and thermobalance reactor, which is essential for thermal conversion of sewage sludge to energy. Three steps are shown for the pyrolysis in TGA and the different pre-exponential factors and activation energies are derived depending on the temperature range. Three models of gassolid reaction were applied to the reaction kinetics analysis for the combustion of sewage sludge char and shrinking core model was an appropriated model. Apparent activation energy and pre-exponential factor were evaluated and the effect of oxygen partial pressure was examined.

The Comparative Analysis of the Method on I/I and Direct Research in Sewer Network (하수관내 불명수 직접측정과 기존 방법의 비교 분석)

  • Choi, Gye-Woon;Baeck, Seung-Hyub;Lee, Ho-Sun;Kim, Dong-Un
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.837-841
    • /
    • 2008
  • 하수관거정비 전 후에 문제관을 판별하고 원인분석에 사용되어지는 불명수 산정방법이 대상유역을 평균적으로 분석하는 방법을 주로 사용하고 있고 이러한 분석방법조차 정확히 어느 정도 실제 불명수 발생량과 일치하는지에 대한 연구도 미비한 실정으로 분석방법의 적용성에 대한 평가가 시급한 상태이다. 본 연구에서는 직접측정이 가능한 대상유역내에서 직접측정과 기존 문헌상 제시되어 있는 침입수/유입수 분석방법(물사용량 평가방법, 일 최대 침입수량 평가방법, 최대-최소 유량 평가방법, 야간 활동인구 사용수량 평가방법, 일 평균 최저유량-수질 평가방법)을 사용하여 하수관거내 I/I량을 산정하였으며, 동일 기간내 실제 현장의 I/I량을 산정하여 비교하였다. 대상지역은 H시로 조사지점은 사전답사 후 6개의 직접측정지점을 선정하고 소유역의 하단에는 유량계를 사용하였으며, 본 조사지역의 주변에 공장이나 물사용량이 많은 시설물은 없었으며 따라서 야간에는 하수발생량이 적게 발생되고, 보다 정확한 조사를 위하여 유량이 거의 발생하지 않는 새벽시간에 직접측정을 실시하였다. 조사기간은 2007년 10월29일부터 11월13일까지 측정하였고 수질의 경우 11월3일과 6일의 평균 채수 값을 사용하였다. 본 연구를 수행한 결과 본 연구의 대상지역인 주거지역이 밀집된 경우 야간생활하수량이 적용되는 야간 생활 하수평가기법이 가장 합리적인 것으로 분석 되었다.

  • PDF

A Study on Risk Evaluation Method of Ground Subsidence around Sewer (하수관로 주변 도로함몰 위험도 평가 방법에 관한 연구)

  • Kim, Jinyoung;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.7
    • /
    • pp.13-18
    • /
    • 2018
  • Recently, road subsidence has been increasing in urban areas, threatening the safety of citizens. In the lower part of the road, various road facilities such as water supply and drainage pipelines and telecommunication facilities are buried, and the deterioration of the facilities causes the road subsidence. In particular, in the case of old sewer pipes which are attracting attention as a main cause of road subsidence, the management of sewer pipe replacement, repair and reinforcement is being performed depending on the burial year. Therefore, in this study, we tried to suggest a reliable road subsidence risk assessment method considering various sewer specifications and surrounding environment information and CCTV exploration result and GPR exploration result.