• Title/Summary/Keyword: 필름 두께

Search Result 656, Processing Time 0.036 seconds

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Tissue Inhomogeneity Correction in Clinical Application of Transmission Dosimetry to Head and Neck Cancer Radiation Treatment (두경부 방사선 치료 환자에서 투과선량 알고리즘의 임상 적용시 불균질 조직 보정에 관한 연구)

  • Kim Suzy;Ha Sung Whan;Wu Hong Gyun;Huh Soon Nyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.155-163
    • /
    • 2004
  • Purpose : To confirm the reproducibility of in vivo transmission dosimetry system and the accuracy of the a1gorithms for the estimation of transmission dose in head and neck radiation therapy patients. Materials and Methods : From September 5 to 18, 2001, transmission dose measurements were peformed when radiotherapy was given to brain or head and neck cancer patients. The data of 35 patients who were treated more than three times and whose central axis of the beam was not blocked were analyzed in this study. To confirm the reproducibility of this system, transmission dose was measured before dally treatment and then repetitively every hour during the treatment time, with a field size of 10$\times$10 cm$^{2}$ and a delivery of 100 MU. The accuracy of the transmission dose calculation algorithms was confirmed by comparing estimated dose with measured dose. To accurately estimate transmission dose, tissue inhomogeneity correction was done. Results : The measurement variations during a day were within $\pm$0.5$\%$ and the dally variations in the checked period were within $\pm$ 1.0$\%$, which were acceptable for system reproducibility. The mean errors between estimated and measured doses were within $\pm$5.0$\%$ in Patients treated to the brain, $\pm$2.5$\%$ in head, and $\pm$ 5.0%$\%$in neck. Conclusion : The results of this study confirmed the reproducibility of our system and its usefulness and accuracy for dally treatment. We also found that tissue inhomogeneity correction was necessary for the accurate estimation of transmission dose in patients treated to the head and neck.

Effect of Irradiation, Packaging and Storage on the Oxidation of Cholesterol and Lipid in Pork Longissimus Meat (돈육 등심의 콜레스테롤 및 지질 산화에 전자선 조사, 포장 및 저장기간이 미치는 영향)

  • 신택순;이정일
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.137-144
    • /
    • 2002
  • Pork loins that retailed in market were used as experimental samples. Some pork samples in raw state were packaged with PVDC in either aerobic or vacuum condition. The other pork samples were cooked until core temperature reached at 70$\^{C}$ and then packaged immediately in the same way with the raw samples. After these samples were irradiated by electron beam 6 kGy, the samples were stored in a refrigerator (2∼4$\^{C}$). Identification and quantification of cholesterol oxides were performed at 0 and 7 days. The results were following. During the early stage of storage, cholesterol oxides were not produced from the raw meat samples, but with the passage of storage time,7 $\alpha$-hydroxycholesterol, 7$\beta$-hydroxycholesterol, 7-ketocholesterol, 20 $\alpha$-hydroxycholesterol, $\beta$-epoxide and $\alpha$-epoxide, which were not produced during the early stage of storage, were produced. The production of cholesterol and lipid oxidation products were significantly higher (P<0.05) in the meats with aerobic packaging than those with vacuum packaging, Cooked meat after irradiation showed 7 $\alpha$-hydroxycholesterol, 7 $\beta$-hydroxycholesterol, $\alpha$-epoxide and cholestanetriol on the 7th day of storage, although those chemicals were not produced during the early stage of storage. Production of cholesterol oxides was significantly increased (P<0.05) with the passage of storage time for all treatments, and showed significantly lower value (P<0.05) with the vacuum packaging than these for aerobic packaging. Species of cholesterol oxides from irradiated meat after cooking were similar to those from cooked meat after irradiation. Collectively, it was found that the production of cholesterol oxides was more easily affected by packaging condition than irradiation.

Loss of the Retinoblastoma Gene in Non-Small Cell Lung Cancer (비소세포폐암에서의 망막모세포종유전자의 소실)

  • Lee, Choon-Taek;Kim, Chang-Min;Zo, Jae-Ill;Shim, Young-Mog;Hong, Weon-Seon;Lee, Jhin-Oh;Kang, Tae-Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.98-103
    • /
    • 1993
  • Background: Inactivation of retinoblastoma gene (Rb) has been observed in a variety of human cancers. Loss of heterozygosity (LOH) of Rb which is a common mode of allelic inactivation of Rb, has been known as a frequent genetic event in small cell lung cancer but it has been detected less frequently in non-small cell lung cancer. To define the role of Rb deletion in lung cancer, we investigated the genomic DNAs of 43 non-small cell lung cancers and 1 small cell lung cancer paired with normal lung tissues obtained by thoracotomy. Methods: The genomic DNAs were obtained by the digestion with proteinase K followed by phenol-chloroform extraction method. The genomic DNAs were digested by restriction endonuclease (EcoRI), separated by agarose gel electrophoresis, transferred to nylon membrane by Southern blot transfer and then hybridized with labelled Rb 1 probe which contains. 1.4 kb sized DNA sequence containing N-terminal portion of Rb. Results: In 26 squamous cell lung cancers, 16 cases were informative after EcoRI digestion and LOH of Rb was found in 10 cases (62.5%). In 17 adenocarcinomas of lung, 11 cases were informative and LOH of Rb was found in five cases (45.4%). The analysis of clinical parameters revealed no significant differences between the two groups with or without LOH of Rb in the aspects of age, sex, degree of differentiation, stage and smoking amount. Conclusions: These results suggest that Rb inactivation is also significantly involved in the molecular pathogenesis of non-small cell lung cancer.

  • PDF

Effect of Several Herbicides in the Polyethylene - film Mulched Young Mulberry Field (P.E. 필름피복(被覆) 밀식(密植) 뽕밭에서의 수종(數種) 제초제(除草劑) 처리효과(處理效果))

  • Kim, Ho-Rak;Kwon, Yong-Woong;Cho, Yong-Woo
    • Korean Journal of Weed Science
    • /
    • v.5 no.2
    • /
    • pp.202-210
    • /
    • 1985
  • Requirements in weed control in a mulberry field are much similar to those in orchards, but also feature a longer period of weed control of various kinds of persistent weeds, i.e., spring, summer, and winter annuals as well as perennials. In addition the mulberry tree is relatively more sensitive to herbicide injury. Hence, very few herbicides have been used in mulberry field. The present study was conducted to evaluate the usefulness of oxyfluorfen in comparison with alachlor and simazine, which are registered for ordinary mulberry field in Korea, for weed control efficacy in the new, rapidly increasing practice of transparent polyethylene-film mulched and densely planted younger mulberry culture. Dominant spring weeds were Galium spp., Erigeron spp., Polygonum senticosum, and Chenopodium spp. in the non-mulched interbed area in contrast to the Digitaria spp. and Potulaca spp, under mulch. Dominant summer weeds were Digitaria spp., Portulaca spp., Erigeron spp., Artemisia spp. and Calystegia japonica in the non-mulched interbed area while weeds did not occur significantly during summer under mulch which were shaded by vigorously growing mulberry trees. The weeds occurred under mulch in spring reduced shoot growth of young mulberry tree resulting in the reduced yield of mulberry leaves for silkworms. The weeds occurred in the interbed area did not affect until May, but interfered later summer- and fall-growth of mulberry tree. Early single spring application of alachlor(EC), simazine(WP) or oxyfluorfen(EC) at a rate of 650 g, 750 g or 350 g ai per ha, respectively, controlled most annuals satisfactorily to fall in the mulched bed area. In the nonmulched interbed area, however, thrice does of alchlor or simazine was necessary for satisfactory control of spring weeds, followed by summer application of alachlor or simazine at twice dose level as tank mixture with paraquat at 490 g ai per ha for satisfactory control of summer to fall weeds. Single spring application of oxyfluorfen at a rate of 1400 g ai per ha was persistently effective to control satisfactorily even summer and fall weeds. However, heavy rainfall splashed soil borne oxyfluorfen to the lower branch leaves causing some leaf burns. Spring application of oxyfluorfen at a rate of 350 g ai per ha followed by summer application of oxyfluorfen and paraquat tank mixture (350 g ai + 490 g ai) was the best choice for the non-mulched interbed area weed control among the treatments.

  • PDF