• Title/Summary/Keyword: 핀 효율

Search Result 177, Processing Time 0.028 seconds

A Study on Spatial Combining power Amplifiers for Backhaul of 5G cellular systems (5세대 이동통신 백홀용 공간 결합 전력 증폭기에 관한 연구)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • In this paper we proposed a new structure of spatial combining power amplifier working in 60GHz global unlicensed band(56-64GHz) for the backhaul in the 5 generation mobile systems. The proposed structure is suitable to realize an antipodal finline transition in millimeter wave band, in which the size of cross section of waveguide becomes about a few mm ${\times}$ a few mm, due to its compact structure of the transition and shows effective heat sinking characteristics because its ground plane can contact to the body metal. However, the HFSS simulation results showed the return loss improvement by 1.27dB and the same insertion loss of -1.65dB compared with the conventional structure, which said nevertheless the advantages, there was no deterioration in the performance.

Effect of Shock Waves on Dynamic Stability of Transonic Missiles (천음속 미사일의 동안정성에 대한 충격파 영향)

  • Park, Su-Hyeong;Gwon, Jang-Hyeok;Heo, Gi-Hun;Byeon, U-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.12-20
    • /
    • 2002
  • Three dimentional unsteady Euler equations are solved and an integration method is presented to predict the dynamic stability derivatives of transonic missiles. Results for the Basic Finner model are compared with several experimental data to vaildate the prediction capability of the present method. The variations of dynamic stability derivatives are discussed with respect to angle of attack, Mach number, and rotation rate. Results show that shock waves between fins enhance the pitch-damping characteristics in transonic region. Results also imply that the Euler equations can give the damping coefficients with comparable accuracy.

Optimal Terminal Guidance Law for BTT Missiles Considering Impact-Angle Constraint of Stationary Target (정지 표적의 표적 충돌각을 고려한 BTT 미사일의 최적 종말 유도 법칙 설계)

  • Yeom, Joon-Hyung;Park, Sung-Min;Ha, In-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1737_1738
    • /
    • 2009
  • 미사일의 표적 충돌각을 원하는 각도로 제어하는 것은 표적의 취약점을 공략하기 위해 필수적인 기술이다. 표적 타격 지점 및 충돌각을 고려하지 않으면 타격에 성공하였다고 하더라도 표적의 방어 능력이 좋거나 신관이 충돌각에 민감하면 표적의 효과적인 파괴에 실패할 수도 있다. 이런 경우 유도 미사일의 종말 유도 효율을 증가시키기 위해 미사일이 표적을 타격하는 각도인 표적 충돌각(Impact Angle)을 제어할 수 있으면 적정 비행경로의 설정에 유리하고 우회공격 등이 가능할 뿐 아니라 미사일 탄두의 효과를 극대화할 수 있다. 하지만 이러한 장점을 갖는 표적 충돌각 유도 기법에 대한 연구는 아직 활발하게 행해지고 있지는 못하다. 기존 연구 결과들은 2차원 평면상에서의 충돌각 제어만을 다루고 있어, 요와 피치 채널의 커플링 문제가 있는 BTT 미사일에 적용하기가 어렵다는 문제점을 갖고 있다. 또한 미사일 동역학을 무시하거나 단순화하여 문제를 풀고 있기 때문에 실제 상황에 적용이 어렵다는 단점이 있다. 본 논문에서는 3차원 공간상에서의 롤 명령을 모두 포함하면서 동시에 미사일 자동조종제어기, 핀 구동기 동역학을 모두 고려한 새로운 BTT 미사일의 표적 충돌각 유도 기법을 제안한다.

  • PDF

Structural Analysis of Space Truss by using New Force Method based on Singular Value Decomposition (특이값 분해로 정식화 된 새로운 하중법을 이용한 입체 트러스 구조 해석)

  • Lee, Su-Hyun;Chung, Woo-Sung;Lee, Jae-Hong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.481-489
    • /
    • 2011
  • In this paper presents new force method by using singular value decomposition. The existing force method has some advantages about analysis of truss structures such as it is easier basic concept than finite element method, which apply to analyze truss structures. However, this method has complex formulation for analysis. Therefore, in this study proposes new force method using singular value decomposition, which is both having easy basic concept and simple computation than existing force method. The proposed method is illustrated through numerical examples.

A Study of Eddy Current Test for fin Tube in Different Fin Height (Fin 높이가 다른 Fin Tube의 와전류탐상에 관한 연구)

  • 이동진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.118-124
    • /
    • 2003
  • 응축기, 증발기, 전열관에 사용되는 Fin Tube는 열전달효율 향상을 위하여 Fin의 높이 를 증가시키고, Tube의 최소두께를 얇게 가공하는 경향으로 발전하고 있다. 따라서, Fin Tube의 와전류탐상(ECT; Eddy Current Testing)에 의한 결함검출에 더욱 어려움이 예상된다. 본 연구에서는 Fin Tube의 Fin 높이를 3단계로 변화시켜 Tube를 제작하고, Tube에 축 방향결함, 원주방향결함, 원형결함을 각각 Fin Tube의 안쪽에 최소두께의 20%, 40%, 60% 의 동일결함율을 갖는 인공결함 시험편을 제작하였다. 제작한 원형결함시험편에 와전류탐상을 수행하여 Fin 높이에 따른 최적주파수의 변화를 연구하였다. Fin높이가 다른 원형결함 시험편에 1~20KHz 주파수를 적용한 결과 최적주파수는 12KHz로 Fin높이에 크게 영향을 받지 않음을 밝혔다 또한 Fin높이에 따른 최적주파수변화는 크지 않으나 Fin 높이가 높을수록 100%관통결함의 위상각(40')에 근접하여 나타났다. 축방향결함, 원주방향결함, 원형결함을 갖는 시험편에 와전류탐상을 수행한 결과 원형결함을 갖는 시험편의 신호 감도가 축방향결함, 원주방향결함보다 좋게 나타났다.

  • PDF

Numerical Study for Configuration Design in the Exhaust Gas Cooling System (배출가스 냉각장치 형상설계를 위한 수치해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.7-12
    • /
    • 2016
  • This paper deals with a parametric study on cooling channel configurations to enhance the cooling effect. As a cooling effect has been increased, the exhaust gas by the plant from a manufacture is becoming deceased. To solve this problem, the design of a efficient cooling system is needed. In this paper, the cooling channel was analyzed to improve the cooling performance. The heat transfer rates depending on the number of baffle and the heiht of fin were obtained by using numerical simulation method. Three-dimensional Reynolds-averaged Naiver-Stokes equations were used to estimate flow and heat transfer in cooling channel, and the $k-{\varepsilon}$ model for turbulence closure was employed.

Metal Catalyst Encapsulated in Nitrogen-doped Carbon Shell for Fuel Cell Application: Theoretical and Experimental Study (연료전지용 질소 도핑 탄소촉매의 표면 반응에 관한 이론적 연구와 실험적 입증)

  • No, Seung-Hyo;Seo, Min-Ho;Gang, Jun-Hui;;Han, Byeong-Chan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.86-86
    • /
    • 2017
  • 고효율의 에너지 변환 및 친환경적인 이점들을 이유로, 고분자전해질 연료전지(PEMFC)는 차세대 에너지 장치로 이목을 끌어왔다. 반면, 값비싼 백금 촉매의 이용은 연료전지의 상업적 이용에 주요한 결점으로 작용했다. 최근, Zelenay와 연구팀은 폴리아닐린-철-탄소 복합체구조에서 산소환원활성이 백금과 견주어 비슷한 성능을 낼 수 있음을 보고 하였다. Dodelet은 이러한 높은 성능이 전이금속의 영향에 의한 것일 수 있다는 주장을 하였다. 본 연구팀은 지난 연구에서 제일원리전산모사를 통해 니켈, 코발트, 구리등과 같은 전이금속이 질소가 도핑된 탄소 그래핀층에 미치는 거동을 밝혔다. 결론적으로, 금속들은 질소가 도핑된 그래핀의 전자구조를 바꿀 수 있고, 이러한 전자구조의 변화는 산소 환원반응에서 긍정적으로 작용할 수 있음을 확인하였다. 이러한 이론적 연구에 기반하여, 탄소층으로 감싼 금속은 내구성과 활성을 동시에 보유한 향후 전망있는 촉매 물질로 예상되어진다. 특히, 질소가 도핑된 탄소층으로 코팅된 철-코발트 합금은 계산을 통해 산소환원반응에서 우수할 것으로 예측되었다. 본 연구팀은 FeCo@N-C 나노입자를 직접 합성하였고, 이 촉매의 우수한 활성을 전기화학적, 구조적 관점에서 1) 질소의 도핑 효과, 2) 탄소의 두께 효과, 3) 합금효과에 집중하여 분석하였다.

  • PDF

Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine (적층형 EGR Cooler의 Pitch 길이 변화가 열교환 특성에 미치는 영향)

  • Hwang, Se-Joon;Kim, Min-Chol;Jang, Sang-Hoon;Kim, Hyung-Man
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • An important goal in diesel engine research is the development of a means to reduce the emissions of nitrogen oxides (NOX). The use of a cooled exhaust gas recirculation (EGR) system is one of the most effective techniques currently available for reducing nitrogen oxides. Since Particular Matter (PM) fouling reduces the efficiency of an EGR cooler, a trade-off exists between the amount of NOX and PM emissions, especially at high engine loads. In the present study, engine dynamometer experiments have been performed to investigate the heat exchange characteristics of the stack-type EGR coolers with wave fin pitches of 3.6 and 4.6 mm. The results show that the heat exchange effectiveness is decreased as surface area decrease with pitch of 4.6 mm due to PM fouling. As surface area increase at pitch of 3.6 mm, super-cooling happens in the recirculated exhaust gas.

A Study on Heat Exchange Efficiency of EGR Cooler for Diesel Engine to Meet Euro-5 Emission Regulation (Euro-5 대응 디젤엔진용 EGR 쿨러의 열교환 효율 연구)

  • Lee, Joon;Han, Chang-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.183-188
    • /
    • 2007
  • Recently, diesel engine has been frequently applied to RV, SUV and light duty truck due to the good fuel economy and high thermal efficiency. $NO_x$ and PM, environmental pollution materials are basically produced in diesel combustion process. The most important target in diesel engine research is the development of system to reduce the emissions of $NO_x$ and PM. Cooled EGR system is an effective method for the reduction of $NO_x$ emission and PM emission from a diesel engine and EGR cooler is the key component of the system. This study investigates the EGR cooler of oval gas tubes compared with the EGR cooler of shell & tubes to verify the heat exchange efficiency of cooler by means of engine dynamometer tests, rig performance tests and numerical analyses.

An experimental study of defrosting behaviors on the fin-tube heat exchanger with PTC heating sheet (PTC 전열시트를 사용한 핀-관 열교환기의 제상 특성에 관한 실험적 연구)

  • Jhee, S.;Lee, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.147-155
    • /
    • 1999
  • In this work, the defrosting characteristics of PTC heating sheet used as a defrosting heat source of fin-tube heat exchanger in a refrigerator have been experimentally compared with those of conventional electric heater. It is found that the characteristics of water draining rate with defrosting time show smoothly oscillating pattern when PTC heating sheet is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is about 75%, which represents about 25% higher than that of the electric heater. A reduction of defrosting time and an increase of defrosting efficiency may be obtained by improving the arrangement of heating elements of the heating sheet. It is shown that the defrosting time of PTC heating sheet increases linearly with the amount of frost, however the defrosting efficiency is nearly constant. In the application to the refrigerating system, one should notice the fact that the defrosting performance of PTC heating sheet may be defraded due to the repeated operations.

  • PDF