• Title/Summary/Keyword: 피복두께

Search Result 323, Processing Time 0.023 seconds

A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape (강재단면형상을 고려한 소요 내화피복 두께 산정에 관한 연구)

  • Kim, Hae-Soo;Kang, Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5910-5916
    • /
    • 2011
  • Surface area of the steel member exposed to fire differs according to type and size of the section and the kind of the member, which shows a big difference in the temperature rise of the steel by fire. The section factor ($H_p$/A) is determined by factors such as type, size, and member of the steel and type of the fire protection material, and it is the criteria in determining thickness of the fire protection material. This study showed that the size of the steel increase regardless of the steel type, the section factor decrease. In the results on fire protection thickness of the steel according to the section factor, the efficiency of 1 hour fire protection was lower from 30 to 50% than the criteria. And there is the member, which have the thickness lower the minimum 27% in 2 hour fire protection, but it generally approached in the criteria. In case of H-shape steel, the efficiency of 3 hour fire protection was suitable for the criteria, but rectangular hollow steel section and circular hollow steel section were higher (5.0-17.5%) than the criteria.

The Effect of Chloride on the Corrosion of Reinforced Concrete (염화물이 철근콘크리트의 부식에 미치는 영향)

  • Kim, Jeong-Sup;Shin, Yong-Seok;Lee, Sul;Kim, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.147-154
    • /
    • 2005
  • It is found that as contents of chloride ion and age increase, area of corrosion also increases. Inare increased to 1035 days from 730 days, slope of increase of corrosion area is greatest. Non-rust inhibitor specimens show corrosion area of 8~35 times more than rust inhibitor specimens and anticorrosive effects by application of rust inhibitor can be confirmed. When chloride ion is not contained, corrosion control effects of steel reinforcing according to increase of thickness are found, but specimens having chloride ion show no regular tend of thickness and corrosion due to complex problems such as reverse diffusion of chloride and test errors.

An Experimental Study on the Shear Resistance of Dowel Bars (장부철근의 전단저항에 대한 실험적 연구)

  • 신장호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.216-223
    • /
    • 1995
  • This research is aimed to investigate the influence of the structural parameters on dowel action of reinforcing bars in reinforced concrete members. I~ollowing the previous research, $^{(3.6)}$ a total of forty two specimens were tested to scrutinize the dowel action of reinforcing bars. Concrete cover, reinforcing bar size and bar distance were taken as main test variables for constant compressive strength of concrete. ]+om the test results, the structural behavior of all specimens was almost linear up to failure load. It is seen that dowel force increases as concrete cover increases. Reinforcing bar size and bar distance hardly affects dowel force. It is found that the dowel forces obtained by this experimental research is relatively close to that of regression analysis results and White's equation.

Corrosion Measurement Method Using Thermographical Information (열화상 정보를 이용한 부식률 예측기법)

  • Yun, Ju-Young;Chung, Lan;Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.142-147
    • /
    • 2007
  • In order to measure corrosion level of steel reinforcement rebar which is inside reinforced concrete structure, infrared thermographic technique was employed. Experimental test parameters were four different ambient temperatures and various levels of corrosion states (0, 1, 3, 5, 7 and 10% of weight loss). After analysis of temperature distributions of concrete surface, the amount of heat flux from the concrete surface is directly proportional to the corrosion level which is inside of concrete.

The Accelerated and Suppressed corrosion of Zircaloy-4 Fuel Cladding in $LiOH-H_{3}BO_{3}$ Solutions ($LiOH-H_{3}BO_{3}$ 용액중 Zircaloy-4 핵연료 피복관의 부식가속과 억제)

  • Han, Jeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.379-386
    • /
    • 1995
  • LiOH-$H_{3}$BO_{3}$ 용액중에서의 Zircaloy-4 핵연료 피복관의 부식가속과 억제현상을 조사하고 이러한 부식특성에 미치는 Li 및 B의 영향을 해석하기 위하여, 여러 조건의 LiOH-$H_{3}$BO_{3}$ 용액을 사용하여 35$0^{\circ}C$, 165bar의 고온, 고압 조건에서 Zircaloy-4 피복관의 노외 부식시험을 수행하였다. 원전 수화학 모의조건에 대응되는 용액 중에서의 부식속도의 천이는 물 분위기에서 보다 빨리 발생되고 천이후 물 분위기와 거의 유사한 부식속도를 나타내는 천이적 후의 부식거동을 보였다. 한편 pH의 변화는 부식특성에 큰 영향을 미치지 않았다. 부식가속과 억제 모의실험으로부터, 산화막내로 침투하는 Li의 양이 용액중 Li 농도에 크게 의존하며, Li 농도가 일정하게 정해진 용액의 경우 B 첨가에 관계없이 산화막내에 일정량의 Li이 농축될수 있다는 가정을 제시하였다. 또한 B 첨가에 의한 부식억제가 B 또는 B-(OH) 화합물의 산화막내 Li 침투 억제에 의한 것이 아니라 일들에 의해 산화막내로 산화성 성분의 이동이 억제되는데 기인할 수 있음을 제시하였다. 부식가속 개시점에 대응되는 산화막 두께측정 결과와 용액내 Li 농도간의 관계로부터, 용액중 Li 농도가 높을수록 부식가속이 얇은 산화막 두께에서 시작됨을 알았다. 특히 노내조건에서의 핵연료 피복관의 부식가속이 산화막내 Li 농축에 의해 일어나는 부식특성으로 해석될 수 있음을 보였다.

  • PDF

An Experimental Study on the Fire Behavior of Two-way Void Slab under Standard Fire with Loading condition (표준화재 재하조건 이방향 중공슬래브의 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Yeo, In-Hwan;Kim, Heung-Youl;Cho, Kyung-Suk;Kim, Jeong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.17-20
    • /
    • 2010
  • 기존의 무량판 구조와 동일한 이방향 슬래브구조인 TVS(two-way void slab)공법은 구조적 하중지지 성능이 불필요한 슬래브 단면상의 중앙부 콘크리트를 제거하여 슬래브의 자중을 줄이고 무량판 구조의 단점을 보완하여 장점을 극대화시킨 구조형식이다. 그러나 이러한 장점을 보유한 공법을 현장적용하기 위해서는 내화성능평가를 통해 화재안전성을 확보하여야 하므로, 이에 대한 화재 실증실험을 수행하여 현장적용을 위한 최소 요구내화 시간에 따른 내화성능 확보방안의 도출이 제시되어야 한다. 이에 본 연구에서는 TVS공법의 실제 스팬길이로 슬래브 피복두께에 따른 화재거동 영향성 분석을 위하여 화재실험을 수행하였다. 하중조건은 고정하중과 적재하중을 고려하여 실험체에 등분포 조건으로 사전재하하였으며, 표준화재조건으로 재하가열 실험을 수행하였다. 슬래브의 화재가열 노출면으로부터의 깊이별 온도변화와 처짐변형 특성을 측정하였으며, KS F 2257-1 평가기준에 의거하여 슬래브의 내화성능을 평가하였다. 실험결과 피복두께 50 mm를 확보할 경우, EPS중공체로 제작한 실험체의 경우 약 2시간정도의 내화성능을 확보할 수 있는 것으로 나타났다.

  • PDF

Natural Zeolite and Sand Capping Treatment for Interrupting the Release of Cd, Cr, Cu, and Zn from Marine Contaminated Sediment and Stabilizing the Heavy Metals (오염된 해양퇴적물 내 Cd, Cr, Cu, Zn의 용출차단과 안정화를 위한 천연 제올라이트와 모래 피복의 적용)

  • Kang, Ku;Kim, Young-Kee;Park, Seong-Jik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.3
    • /
    • pp.135-143
    • /
    • 2016
  • We investigated the effectiveness of natural zeolite (NZ) and sand (SD) as a capping material to block the release of heavy metals (Cd, Cr, Cu, and Zn) from heavily contaminated marine sediments and stabilize these heavy metals in the sediments. The efficiency of NZ and SD for blocking trace metals was evaluated in a flat flow tank attached with an impeller to generate wave. 0, 10, 30, and 50 mm depth of NZ or SD were capped on the contaminated marine sediments and the metal concentration in seawater was monitored. After completion of flow tank experiments, sequential extractions of the metals in the sediment below the capping material were performed. The difference of pH, EC, and DO concentration between uncapped and capped condition was not significant. The release of cations including Cd, Cu, and Zn were effectively blocked by NZ and SD capping but the interruption of Cr release was observed only in 50 mm depth of SD capped condition. However, the stabilization of Cr in 50 mm depth of SD capped condition was not achieved when compared to uncapped condition. NZ and SD capping were effective for stabilizing Cd, Cu, and Zn in marine sediments. It is concluded that the use of NZ with SD as a capping material is recommended for blocking Cd, Cr, Cu, and Zn release and stabilizing them in contaminated marine sediments.

An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection (내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구)

  • Kim, Hae-Soo;Lee, Chy-Hyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.

A Study on the Anti-Spalling Performance of High-Strength Concrete Members by covered Engineered Cementitious Composite (ECC로 피복된 고강도콘크리트 부재의 폭렬억제성능에 관한 연구)

  • Lee, Jae-Young;Kim, Jae-Hwan;Han, Byung-Chan;Park, Sun-Gyu;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites (ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 5 HSC specimens are being exposed to fire, in order to exami ne the influence of vari ous parameters (such as depth of layer=20, 30, 40 mm; construction method=lining and repairing type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion (3 hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

Effect of NaCl and Fluoride adsorbates on Zircaloy-4 Oxidation in Air. (지르칼로이 피복관의 공기중 산화에 NaCl과 불화물의 영향)

  • 박광헌;김광표;조윤철
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.105-105
    • /
    • 1999
  • 핵연료 피복관은 핵연료에서 방사성 핵분열생성물의 방출을 저지하는 가장 뚱요한 방어막인데, 현재 지르칼로이 4가 피복관의 재료로 사용되고 있다. 사용후 핵연료는 원자력발전소내 습식 저장조에 저장되고 있으나, 지속적인 관리와 장소확보의 용이 성으로 인해 건식 저장조를 사용하는 추세에 있다. 본 연구에선 건식 저장조에 장 기간 저장되는 핵연료 피복관에 주변 환경으로부터 오염될 수 있는 소금기나 기름 등이 지르칼로이의 공기중 산화에 미치는 영향의 존재를 밝히려 한다. 현재 고리 원자력발전소에서 사용중인 핵연료 피복관을 1cm정도 높이로 자르고, 피복관 표면 을 ASTM -G2-88 방법으로 처리한 후 산화실험을 수행하였다. 산화정도는 간헐적 (intermittent) 방법을 사용하여 시편의 무게를 측정하여 구하였으며, 산화온도는 $400-500^{\circ}C$로 하였다. 소금이 흡착이 된 경우, 산화 속도는 흡착이 안된 시편보다 가속되었으며, 거의 이차법칙을 따르고 있다. 산화막 위의 흡착물의 영향을 알아보기 위해, 지르칼로이를 $500^{\circ}C$ 수증기에 $5g/m^2$ 두께로 산화시킨 후, 다시 산화실험을 수행하였다. 사용한 흡착물은 LiF, NaF, KF, NaCI 이다. 흡착물들은 산화를 대체로 가속시켰으며, NaF, KF, NaCI 순으로 그 영향력이 컸다. 그러나, LiF는 산화에 전혀 영향을 미치지 않았다. SIMS를 사용하여 각 시편의 두께에 따른 흡착물의 분포 를 알아보았다. 음이온(CI, F)과 양이온(Na, Li, K)이 산화막과 금속 경계면까지 관 찰되었으며, 음이온과 양이온의 분포는 대게 동일하였다. LiF의 경우 산화막에서 이들의 농도가 급격히 떨어지고 있음을 알 수 있었다. 산화막 내에서 이들 흡착물의 확산이 산화속도 가속의 원인이며 이들 흡착물중 CI과 F는 산화막과 금속 겸계면 에서 새로 생성되는 산화막의 강도에 영향을 미쳐, 일찍 미세균열을 만들기 시작하여 산화를 가속시키는 것으로 판단된다.

  • PDF