• Title/Summary/Keyword: 피난해석

Search Result 104, Processing Time 0.019 seconds

Development of the Program(FDS2EXODUS) for Generating Hazard condition file of Building-EXODUS code based on the FDS Fire-simulation Data (화재모사전용 FDS code의 계산값을 이용하여 피난해석 BuildingEXODUS code의 피난의 환경조건 파일을 생성하는 프로그램(FDS2EXODUS) 개발)

  • Kim, H.B.;Jang, Y.J.;Jung, W.S.;Park, W.H.;Lee, D.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.570-575
    • /
    • 2009
  • In this paper shows the development of the Program(FDS2EXODUS) for Generating Hazard condition file of BuildingEXODUS code based on the FDS Fire-simulation Data. The program were applied with numerical method to translate from FDS to BuildingEXODUS. Using both single or multi block meshes of FDS get to be possible. For application of fire effect, the fire data were loaded directly to BuildingEXODUS in the case of FDS code with using this Program(FDS2EXODUS). It was very convenient to input to BuildingEXODUS and could be reduced the procedure of egress simulation from fire disaster.

  • PDF

A Study on Statistical Analysis of Residents' Escape Behavior due to the Vertical Evacuation Direction in a High-rise Apartment (고층 아파트 재실자의 수직적 이동방향별 피난행동에 관한 통계적 해석연구)

  • Kim, Jae-Hong;Choi, Jun-Ho;Hong, Won-Hwa
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.267-272
    • /
    • 2010
  • 전 세계적으로 수많은 고층 건축물이 건설되고 있다. 건축물의 높이가 높아질수록 비상시 필요로 하는 유효 피난길이와 총 피난시간은 점점 길어진다. 일반적으로 건축물에서의 피난은 지상층의 안전한 공간으로 대피하는 것을 의미하는데 고층 또는 초고층 건축물의 대규모 수직적 공간에서는 하향식 피난뿐만 아니라 상향식 피난도 고려되어야 한다. 이를 위해 본 연구에서는 고층 아파트 1개소를 선정하여 수직적 이동방향에 따른 실물 피난실험을 실시하여 피난특성을 관찰하였다. 본 실험에서 피난자 개개인의 특성을 파악하기 위해 피난자들이 지상층에 도착하자마자 설문조사를 실시하여 피난행동간 개인 고유의 행동데이터를 수집하였고 이를 PASW 18을 활용하여 통계적 해석을 실시하였다.

  • PDF

Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade (지하상가 출입구 방풍문 설치에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • This paper presents a study on the evacuation analysis in underground arcade. In this study, the effect of the exit with a windbreak door has been investigated by using evacuation simulation program (building EXODUS). Also, the simulation has included the impact of smoke, heat and toxic gases by fire simulation program (CFAST). The results were obtained for the conditions of without and with door of the two exit with 1,088 evacuation population. As a results, for non-fire evacuation, there was only a little difference of evacuation time for both conditions. However, for fire emergency evacuation, the evacuation time for the condition with door increased more 110 seconds than for the condition without door. When the auto door not opened, the evacuation time was increased more 670 seconds than for the condition without door. Consequently, in case of fire, the automatic door should be operating by the signal of fire detector and keep open when the fire accidents. To lead the evacuees well to the escape route the luminaries for an emergency exit sign have to be reinforced to the wall and floor around the exit.

The Analysis of Evacuation Safety by Smoke Alarm in Housing Fire (주택형화재경보기 작동에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Bak, Yeul-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.73-82
    • /
    • 2011
  • This study was performed to analysis the influence of smoke alarm detector on evacuation safety in housing fire. The analysis was conducted by CFAST fire simulation program and building EXODUS evacuation program. The effects of the earlier response time on evacuation safety were investigated by using evacuation simulation program with several steps of different response time and smoke alarm activation time for 4 occupants. The smoke detecter was activated 37.1 second after fire. The first two mortuary were occurred for 170 seconds of response time at the end of living room near exit. But for the 37.1 seconds of response time 4 occupants evacuated safely. From this study, the fire alarm detector is more important for safety evacuation in housing fire.

Case Study on Vessel Evacuation Characteristics during Blackout Conditions (선내 정전시 피난특성 예측 사례연구)

  • Hwang, Kwang-Il;Kim, Kyoung-Won;Cho, Ik-Soon;Lee, Yun-Sok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.67-68
    • /
    • 2015
  • 선상에서의 승객들의 보행속도, 운항 중 피난특성, 피난시 연기농도가 미치는 영향 등 선박에서의 피난상황을 해석하는 데 필요한 몇몇 연구가 수행된 바 있다. 그러나 정전 조건에서 승선자의 피난성능에 관한 연구는 미비하여, 이론적 혹은 실험적 연구가 수행된 사례를 찾아보기 어려운 상황이다. 이에 이 연구에서는 선박에서의 인적안전피난해석 프로그램인 Maritime EXODUS를 활용하여 승선자의 분포특성을 고려한 세 가지 시나리오에 대한 피난시간을 예측 비교하였다. 이 연구에서는 선행된 운항훈련선의 선내 정전조건보행실험에서 취득한 피실험자 보행속도 결과를 반영하였다.

  • PDF

여객선의 힐링각 변화에 따른 피난성 예측

  • Hwang, Gwang-Il
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.270-271
    • /
    • 2014
  • In spite of the methodology of evacuation process on vessels should be different comparing to the architecture on land, some have simulated the evacuations onboard ship with simulation tools which is developed only for the architecture. On this study, a vessel-oriented simulation tool is used to analyze the possibility of evacuation for a passenger ship. ${\cdots}$(중략)${\cdots}$ As a result of the simulation analysis, it is clear that the initial responding time and start-to-move time are so important, ${\cdots}$(중략)${\cdots}$.

  • PDF

A Study of Effect of the Radiative Heat Flux on the Evacuation of Agents (화재에 의해 발생하는 복사열이 재실자의 피난거동에 미치는 영향에 관한 연구)

  • Bae, Sungryong;Kim, Jung-Yup;Shin, Hyun-Joon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Recently, the safety assessments with using the various evacuation programs are performed for improving the performance of fire and evacuation safety in the building. Generally, the evacuation programs can simulate the human behavior in fire situation by applying the variation of the movement speed and Fractional Effective Dose (FED) index in the smoke. However, if the simulation is performed without optional setting around the fire, the agents do not avoid the fire and they move through the fire. Therefore in this study, we define the radiative repulsion force which exists between the fire and the agents. Moreover, we modify the Helbing's movement model by adding the radiative repulsion force. As a result of the modified movement model, all agents move around the fire and they do not enter the upper bound area of radiative heat flux, $2.4kW/m^2$. From these results, we verified the reliability of the modified movement model.

Define a detailed model for developing a program of domestic buildings evacuation simulation (국내 건축물 피난프로그램 개발위한 세부모델 정립)

  • Youn, Ho-Ju;Hwang, Eun-Kyung;Kim, Jong-Sung;Kim, Jong-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.42-47
    • /
    • 2010
  • 최근 피난 및 소화활동의 제약이 많은 대형 및 고층건축물의 증가함에 따라 화재 시 많은 인적 물적 피해가 예상된다. 이에 국내외에서는 화재로부터 인명 및 재산을 보호하기 위한 방법으로 종합적이고 과학적인 성능위주 소방설계를 실시하고 있으며 이를 위해서는 건축물의 화재 및 피난에 대한 공학적 분석이 요구되는데 현재는 대부분 컴퓨터 시뮬레이션 프로그램이 활용되고 있다. 이러한 컴퓨터 피난프로그램은 국내에서 아직 상용화된 프로그램 없어 외국 피난프로그램과 데이터를 그대로 활용 하고 있다. 국외의 피난 프로그램은 국내의 건축물 및 재실자의 특성을 정확하게 반영할 수 없으며 알고리즘 또는 해석방식에 대한 이해가 어려워 잘못된 분석결과를 가져올 수도 있다. 이에 본 연구에서는 국내의 상황을 반영할 수 있는 피난프로그램 개발을 하고자 국내에서 활용 되고 있는 피난 프로그램의 세부모델에 대한 분석을 통해 피난 프로그램의 국내 피난 프로그램의 세부모델의 개발방향을 설정을 하고자한다.

  • PDF

Flow-structure Interaction Analysis for Durability Verification by the Wind Force of Outdoor Evacuation Stairs (옥외형 피난계단의 풍압에 따른 내구성 검증을 위한 유동-구조 연성해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-102
    • /
    • 2020
  • In this study, one-way fluid structure interaction analysis was adapted to verify the durability of the outdoor evacuation stair structure operated in the event of a fire when wind pressure caused by a typhoon was applied. To this end, flow analysis was performed with the flow field around the structure of the evacuation stair in a steady state, and the durability was analyzed through structural analysis such as structural stress, deformation, and fatigue life using these analysis results by fluid data input data for structural analysis. As a result of flow numerical analysis, the air flow was different according to the shape of the evacuation stair structure, and this flow velocity distribution generated by the total pressure on the structure surface. Through the structural analysis results calculated by this total pressure, the safety factor calculated as the maximum stress value was found to be more than the safety factor, and durability was proven by fatigue life and deformation analysis.

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.