• Title/Summary/Keyword: 피난안전구획

Search Result 20, Processing Time 0.018 seconds

A Study on the Management of Evacuation Safety Zone through the Prediction of Smoke Movement (재난약자시설의 연기성상 예측을 통한 피난안전구획 관리에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Han, Ji Woo;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.100-101
    • /
    • 2019
  • For buildings where a large number of the evacuees who are restricted to evacuation behavior compared to normal people, evacuation safety zones should be secured against fire. In order to form a safe haven safety zone, we are going to predict the performance of the building and describe the plan to secure a safe haven zone accordingly.

  • PDF

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.

Case Study about Performance Based Design through Fire & Egress Simulation for Atrium of A Hotel & Casino (A 호텔 & 카지노 아트리움의 화재 및 피난시뮬레이션을 통한 성능위주설계 사례연구)

  • Park, Chang-Bok;Lee, Yong-Ju;Kim, Min-Ju;Yoon, Myong-O;Choi, Young-Hwa;Park, Jae-Sung;Kim, Hwan-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2009
  • This study is related with fire risk assessment for occupant of the area adjacent to not enclosed atrium through the computer modeling and application of enhanced fire protection systems depending on the result. Fire scenario is intended to evaluate the impact of a fire from atrium base within the corridor adjacent to the atrium and to compare with egress time depending on the warning system. The major purpose of this study is to figure out fire life safety for occupant adjacent to atrium through the computer simulation and to suggest alternative option in case the occupant safety is not guaranteed.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot (지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구)

  • Song, Young-Joo;Kong, II-Chean;Kim, Hak-Jung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • Today, building constructions are becoming larger, higher, deeper, and complex to improve quality of human life and meet various needs. As a result, new design space for non - typically standardized space has been created, and targets for performance-based design are also becoming increased. An evacuation safety evaluation of performance-based design should be compared with ASET and RSET estimation so that the value of RSET does not exceed the value of ASET. However, there is a problem that it is difficult to secure the safety with using the performance-based design evaluation method currently in use, especially in case of the underground parking lot, because it has wide compartment area and various routes for evacuation. Therefore, in order to overcome these problems, this paper first investigates the simulation setting method of the performance-based design that is currently in use, and then conducts two fire simulations and three evacuation simulations for underground parking lots each time, so performs the evacuation safety evaluationin total six cases of situations. Here this paper analyzes the problem with comparative evaluation research and suggests the better solution for improved evacuation safety evaluation of performance-based design.

A Study on the Recognitions on Evacuation and Architectural Design Characteristics of Child Care Center with Disabilities (장애아 전문 어린이집 피난인식 및 건축현황 분석 연구)

  • Lee, Jeong-Soo;Oh, Young-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.617-624
    • /
    • 2018
  • The purposes of this study are to propose architectural design and evacuation management guidelines for child care center with disabilities. To achieve these purposes, the questionnaire has carried out for director who manage child care center and analyzed the architectural characteristics of child care center for children with disabilities. The results of this study are as follows : (1) 65.3% directors think that less than 30% of children with disabilities in child care center can evacuate by oneself, and 73.2% of child care centers have difficulties for safe evacuation because of more than 50% of children with complex disabilities. (2) The moving or visual impaired children who live more than 2nd floors are need safe refuge areas for waiting in child care centers. (3) The child care centers for children with disabilities which were renovated from housing and multi-family housing have difficulties in vertical evacuating, and needs renovating for promotion of convenience and evacuation of children with disabilities.

A Study on the Consideration Factors for the Calculation of Elevator Evacuation Time (엘리베이터 피난계산 고려인자에 관한 연구)

  • Kim, Hak-Joong;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.8-14
    • /
    • 2010
  • It is more important to study for reducing the evacuation time of occupant in fire, because the building has been taller and deeper. It has known that elevator was not safe in fire situation. So, the using elevator for evacuation has been prohibited. But the study of elevator evacuation is progressed with designing the elevator safe from flame and smoke. This study analyze the consideration factors for the calculation of elevator evacuation time. The factors for elevator evacuation calculation is starting time, round trip time. And round trip time is divided into standing time and travel time. The elevator evacuation time can be calculated by compounding these factors and adding the efficiency. For using elevator to evacuate, we need additional study for smoke control, compartment, water proof and safe electric power supply.

방화문의 구조설계

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.6 s.66
    • /
    • pp.36-42
    • /
    • 1974
  • 설계가 잘 되어있는 문은 사람이나 물건의 출입에 큰 지장을 주지않고 분리, 차음 및 안전등의 제기능을 충분히 발휘할 것이다. 화염이나 연기의 확산을 조지시키는 일은 안전상 가장 중요한 일 중의 하나이다. 건물의 여러곳에 위치한 문의 기능, 성능의 평가방법과 기준등은 전세계에서 논의의 대상이 되고 있다. 건물의 각부분은 내화구조구획에 의해 각각 분리될 수 있으며, 각 구획을 통하는 개구부는 화재시 자기의 기능을 충분히 발휘할 수 있는 문에 의해 차단될 수 있다. 첫째, 문은 그 문이 위치한 벽체에서 화재차단의 효과를 가져야 하며, 둘째, 피난통로의 안전을 조해하는 연소부산물이 침투하는 것을 방지하여야 한다. 그러므로 모든 방화문은, 건물에서 그 위치의 정도에 따라 연기와 화재의 확산을 막는 장벽으로서의 역할이 요구된다. 본 내용은 현재 논의되고 있는 상황에 대한 영국건축연구소의 연구보고서의 요약 소개이다.

  • PDF

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.

A Study on Escape Safety Assessment of High-Rise Office Buildings for Security Plans (경호경비계획을 위한 사무용 고층건축물의 피난안전성평가에 관한 연구)

  • Park, Nam-Kwun;Lee, Young-Ju;Yoon, Myong-O
    • Korean Security Journal
    • /
    • no.28
    • /
    • pp.57-77
    • /
    • 2011
  • Recently, property and life loss is increasing internally and externally, due to fire spread in high-rise buildings which results from a variety of disasters like fire and terror. In this study, therefore, an evacuation simulation was performed to predict escape behaviors of occupants and assess escape safety in high-rise office buildings after setting up each scenario, as part of safety measures for high-rise buildings. Based on the results and data obtained, escape safety was assessed, finally. The results and suggestions of this study are as follows. Firstly, most of the present researches on high-rise building and multiple-use facilities are weighted towards qualitative perspectives. It is, therefore, considered that we have to establish concrete, practical, systematical and rational safety measures to minimize damages in dangerous situations, by analyzing security plans for high-rise buildings in depth and preparing for those situations from various angles. Secondly, setting up evacuation sections in security plans for high-rise buildings is an important factor which influences refuge. Thirdly, in relation to security plans for high-rise buildings, it is possible to reduce the entire time for escape, by setting up escape exits of each floor in consideration of a simultaneous evacuation situation.

  • PDF