• Title/Summary/Keyword: 피난대피

Search Result 168, Processing Time 0.029 seconds

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Development Plan of Facility Importance, Risk, and Damage Estimation Inventory Construction for Assisting Disaster Response Decision-Making (재난대응 의사결정 지원을 위한 시설물 중요도·위험도·피해액 산정 인벤토리 구축 방안 연구)

  • CHOI, Soo-Young;GANG, Su-Myung;JO, Yun-Won;OH, Eun-Ho;PARK, Jae-Woo;KIM, Gil-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.167-179
    • /
    • 2016
  • The safety of SOC facilities is constantly under threat by the globally increasing abnormal climate. Responding to disasters requires prompt decision-making such as suggesting evacuation paths. For doing so, spatio-temporal information with convergence of disaster information and SOC facility information must be utilized. Such information is being collected separately by the government or related organizations, but not collectively. The collective control of the separately collected disaster information and the generation of SOC facility safety and damage information are required for prompt disaster response. Also, as disaster information requires spatio-temporal convergence in its nature, the construction of an inventory that integrates related information and assists disaster response decision-making is required. A plan to construct a facility importance, risk, and damage estimation inventory for assisting prompt disaster response decision-making is suggested in this study. Through this study, the disaster and SOC facility-related data, which are being managed separately, can be collected and standardized. The integrated information required for the estimation of facility importance, risk, and damage can be provided. The suggested system is expected to be used as a decision-making tool for proactive disaster response.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.

A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility (화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로)

  • Kim, Bongjun;Ryu, Guhwan
    • Journal of Digital Convergence
    • /
    • v.18 no.9
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, in order to propose an improvement plan for fire simulation training to improve fire response capability, fire simulation training is conducted for three business facilities, and changes according to whether training materials are used and whether the response time for each response stage is reflected in the training evaluation. The response posture and response ability of the training participants were observed and analyzed. As a result of the analysis, it was analyzed that most of the training participants improved their participation in training, response posture, and response ability when the use of training textbooks and response time for each response stage were reflected in the training evaluation. In the event of a fire simulation training, a number of training materials that can similarly implement the fire situation are used to improve and maintain the fire response capabilities (fire notification and fire report, initial extinguishing, and evacuation) of the training participants, and the target time for each response step. The result was that it can be used as a useful index for improving fire response capability and improving fire simulation training in the future and feedback only when quantitative training evaluation is conducted based on this setting.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

Investigation on Users' Perception and Certification Status and Donning of Smoke Masks (방연마스크에 대한 사용자 인식, 인증 현황 및 착용성 조사)

  • Hyunwoo Son;Yeongeun Park;Eungwoo Lee;Eunji Kim;Youngbo Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.68-73
    • /
    • 2023
  • Smoke masks have attracted great interests and have been supplied widely for the improvement of the safety during fire evacuation. However, there is not sufficient research on the practical utility, certification status and easy-donning about commercial smoke masks, therefore it is difficult to determine the actual usefulness of the smoke masks. In this study, we conducted a survey on users' perceptions and experiences about the smoke masks, and investigated the status of certification of 54 commercial smoke masks. We also performed donning tests and examined degrees of discomfort for 4 types of the smoke masks. Although 22% of 235 respondents had experienced the smoke masks before the test, and 23% of the respondents did not know the smoke masks, 93% of the respondents expected that the smoke masks could protect users from fire smokes and toxic gases. It was found that 41% of the commercial smoke masks did not certify according to domestic or overseas performance standards. Most certification standards have not effectively regulated maximum wearing time for the smoke masks. Only ASTM E 2952 and KFIS 024 had specific standards for the maximum wearing time of 30 s. As a result of donning tests for 4 types of smoke masks, the wearing time of the hood-type mask and self-contained smoke mask exceeded 30 s, therefore these types of smoke masks might increase the required safe evacuation time. On the other hand, it was also found that short education about the donning could reduce the wearing time by 19% and numbers of improper wearing by 89%.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.