• Title/Summary/Keyword: 플라즈마중합

Search Result 142, Processing Time 0.024 seconds

Changes of Chemical Concentrations during Pulsed Plasma Process of Silane (실란 펄스 플라즈마 공정에서의 화학농도 변화)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.141-149
    • /
    • 2005
  • We investigated numerically the evolutions of several chemical species which are important for film growth and particle generation in the pulsed $SiH_4$ plasmas. During the plasma-on, the $SiH_x$ concentration increases with time mainly by the generation reaction from $SiH_4$, but, during the plasma-off, decreases because of the hydrogen adsorption reaction. During the plasma-on, the concentrations of negative ions increase with time by the polymerization reactions of negative ions and those become almost zero in the sheath regions because of the electrostatic repulsion. During the plasma-off, the concentrations of negative ions decrease with time by the neutralization reactions with positive ions and some negative ions can diffuse toward the sheath regions because there is no electric field inside the reactor. The polymerized negative ions of higher mass can be reduced successfully by using the pulsed plasma process.

  • PDF

Nonthermal plasma on the shear bond strength of relining resin to thermoplastic denture base resin (열가소성 의치상 레진과 첨상용 레진의 접착 강도에 저온플라즈마가 미치는 효과)

  • Manaloto-Ceballos, Liezl;Labriaga, Wilmart;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.199-205
    • /
    • 2018
  • Purpose: This study evaluated the effect of nonthermal plasma treatment on the bond strength of autopolymerizing relining resin to the injection molded thermoplastic denture base resins (TDBRs) with different surface treatments. Materials and methods: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast) and Polypropylene (Weldenz) were subjected to various surface treatments: No treatment, Nonthermal plasma, Sandblasting, Sandblasting and nonthermal plasma. Specimens were bonded using an autopolymerizing relining resin. Shear bond strength was tested using universal testing machine with crosshead speed of 1 mm/min. Statistical analysis by two-way analysis of variance with Tukey's test post hoc was used. Results: Acrytone showed significantly higher shear bond strength value among other TDBR group while Weldenz had the lowest. The sandblasting and nonthermal plasma condition had significantly higher shear bond strength value in all of the resin groups (P < .05). Conclusion: The use of nonthermal plasma treatment showed limited effect on the shear bond strength between TDBRs and relining resin, and combination of nonthermal plasma and sandblasting improved the shear bond strength between TDBR and reline material.

THE COMPARISON OF POLYMERIZATION OF COMPOSITE RESIN INFLUENCED BY CURING DEPTH AND SHADE (광중합 복합레진의 색상과 깊이에 따른 중합도의 비교)

  • Choi, Kung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.280-289
    • /
    • 2004
  • Adequate polymerization is a crucial factor in obtaining optimal physical properties and clinical performance of resin composite restorative materials. The purpose of this study was to determine the effectiveness of shade and depth on dental composite resin polymerized with plasma arc curing unit employing FTIR and microhardness. From this experiment, the following results were obtained : 1. The light transmission and microhardness by mode 6 in plasma arc curing were similar to by 20 secs in halogen light curing. 2. The experimental groups of A1, A2, A3, A3.5 were not signifcant difference to light transmission and microhardness on surface and 2mm depth, but were significant difference on 3mm and 4mm depth. Especially light transmission and microhardness were small in darker shade and deeper thickness. 3. Compared with depth cure, uncured monomer amount increased at more than 2mm depth. 4. The light transmission by FTIR and polymerization by microhardness were significant corelation.

  • PDF

Evaluation of New LED Curing Light on Resin Composite Polymerization (발광 다이오드 광중합기의 복합레진 중합 평가)

  • Kang, Jieun;Jun, Saeromi;Kim, Jongbin;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.152-156
    • /
    • 2014
  • The purpose of this study is to compare efficiency of broad spectrum LEDs ($VALO^{(R)}$, Ultradent, USA) with conventional LED curing lights ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA) using a microhardness test. The light curing units used were $VALO^{(R)}$ in three different modes and $Elipar^{TM}$ Freelight 2. The exposure time was used according to the manufacturer's instructions. After cured resin specimens were stored in physiological saline at $37^{\circ}C$ for 24 hours, microhardness was measured using Vickers microhardness tester. The microhardness of upper and lower sides of the specimens were analyzed separately by the ANOVA method (Analysis of Variance) with a significance level set at 5%. At upper side of resin specimens, an increased microhardness was observed in the broad spectrum LED curing light unit with a high power mode for 4 seconds and plasma emulation mode for 20 seconds (p < 0.05). However, at the lower side of resin specimens, there were no significant differences in microhardness between broad spectrum LED curing light unit and conventional LED curing light unit.

A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD (스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구)

  • Kim, Yeun-Chul;Kim, Jong-Soo;Kwon, Soon-Won;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.19-29
    • /
    • 2002
  • The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

  • PDF

The study on electrical conduction mechanism of plasma-polymerized methyl methacrylate (PPMMA) (플라즈마중합 PPMMA의 전기전도 기구에 관한 연구)

  • Park, Jae-Youn;Park, Kwang-Heun;Han, Sang-Ock;Lee, Deok-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.283-285
    • /
    • 1987
  • Transient conduction current (I - t characteristics) were measured in thin PPMMA (plasma-polymerized methyl methacrylate) films over the temperature range $60^{\circ}C-140^{\circ}C$ and the applied voltage range 3V - 30V. The current, which increased with temperature rise at constant applied voltage, showed less absorption current (current decay with time) at higher temperature region compared with those at lower temperature region. And the current, which increased with applied voltage rise at the constant temperature, showed less absorption current at higher voltage compared with those at lower voltage. The electric field current density characteristic curves were abtained from the conduction current values were after applying voltage for 30 minutes. And transient conduction currents were analyzed with high field conduction theories.

  • PDF

Nanometer Scale Vacuum Lithography using Plasma Polymerization and Plasma Etching (플라즈마 중합과 플라즈마 에칭을 이용한 나노미터 단위의 진공리소그래피)

  • 김성오;박복기;김두석;박진교;육재호;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.131-134
    • /
    • 1998
  • This work was carried out to develop a pattern on the nanometer scale using plasma polymerization and plasma etching. This study is also aimed at developing a resist for the nano process and a vacuum lithography process. The thin films of plasma polymerization were fabricated by the plasma po1ymerization of inter-electrode capacitively coupled gas flow system. After delineating the pattern at accelerating voltage of 30[kV]. ranging the dose of 1∼500[${\mu}$C/$\textrm{cm}^2$], the pattern was developed with dry tree and formed by plasma etching. By analysing of the molecule structure using FT-lR, it was confirmed that the thin films of PPMST contains the functional radicals of the MST monomer. The thin films of PPMST had a highly crosslinked structure resulting in a higher molecule weight than the conventional resist.

  • PDF

Reduction of Contraction Coefficient of Acrylic Yarn by PFP Plasma Polymerization (PFP 플라즈마중합에 의한 아크릴 섬유사의 수축률 감소)

  • Kang, Young-Reep
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.287-291
    • /
    • 1999
  • Plasma polymerization of Perfluoropropene(PFP) was carried out in a tubular type reactor. The Plasma was generated by coupling inductively under the fixed discharge power of 25W and the pressure of 100, 140, and 200 mTorr of radio frequency generator. PFP plasma polymerization thin films were deposited in acrylic yams. For 1 hours, the acrylic yams treated and untreated by PFP plasma were immersed in boiling water. Then the reduction of contraction coefficient of acrylic yams were measured respectively. As a result of this experiment, untreated acrylic yams were reduced around 23%, while treated yams were contracted about 18-2%.

A Study on the polymer humidity sensor using plasma polymerized films. (플라즈마 중합막을 이용한 고분자 습도센서에 관한 연구)

  • Shin, P.K.;Lee, D.C.;Park, G.B.;Park, C.B.;Yun, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.198-200
    • /
    • 1991
  • In this study we fabricated thin organic polymer films on the comb-electrode by plasma polymerization methode in electrode gas flow type reactor. The dielectric constant of polymer films were increased by increasing relative humidity and we used free volume theory in order to explain the mechanism of water absorption phenomena of polymer films.

  • PDF